Nattapon Chantarapanich

Dr. Nattapon Chantarapanich

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2014 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
DPDumnoensun Pruksakorn
Dumnoensun Pruksakorn
NCNattapon Chantarapanich
Nattapon Chantarapanich
OAOlarn Arpornchayanon
Olarn Arpornchayanon
TLTaninit Leerapun
Taninit Leerapun
KSKriskrai Sitthiseripratip
Kriskrai Sitthiseripratip
NVNatapoom Vatanapatimakul
Natapoom Vatanapatimakul

8 January 2021 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
NCNattapon Chantarapanich
Nattapon Chantarapanich
AGArthit Gromprasit
Arthit Gromprasit
CMChantas Mahaisavariya
Chantas Mahaisavariya
CPChawanan Patamamongkonchai
Chawanan Patamamongkonchai

17 November 2022 in Medical Engineering & Physics
Verified
Journal Article
Closed access
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
NCNattapon Chantarapanich
Nattapon Chantarapanich
AGArthit Gromprasit
Arthit Gromprasit
CMChantas Mahaisavariya
Chantas Mahaisavariya
KSKritsada Sukha
Kritsada Sukha
SCSuwichote Chiawchan
Suwichote Chiawchan
The optimal technique for managing distal femur fixation failure remains inconclusive. The author studied the efficacy of a combined proximal humerus locking compression plate (LCP-PH) and 3.5 mm reconstruction plate (LCP-RP) by finite element (FE) analysis and retrospectively described the clinical outcomes of the present technique in such difficult circumstances. Biomechanical study setting included FE models of the distal femur with remaining holes from previous distal femur LCP (LCP-DF) fixation stabilized with three different constructs i.e., LCP-DF alone, LCP-DF-and-LCP-RP, as well as LCP-PH-and-LCP-RP. All settings were analyzed by using FE under physiological loads. Regarding the clinical series, the outcomes of 8 LCP-DF fixation failures operated on by the present technique were retrospectively reviewed. High Implant stress of 911.2 MPa and elastic strain at fracture site of 200.8 µɛ were found when stabilized with LCP-DF. The constructs of LCP-DF-and-LCP-RP, and LCP-PH-and-LCP-RP presented lower implant stress compared to LCP-DF, 511.5, and 617.5 MPa, respectively. The elastic strain of both dual plating constructs was also 4-5 times lower than LCP-DF and differed from each other by approximately 10 µɛ. Regarding the clinical series, bony consolidation was achieved in all cases with a mean duration of 28.5 weeks (range 24-36). An average ROM of the affected knee was 115° (range 105-140). Regarding the KSS, 1 was determined to be excellent and 7 to be good. By the biomechanical analysis and the clinical results, the construct of LCP-PH-and-LCP-RP could be an effective technique for revision surgery of LCP-DF fixation failure.

22 June 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CMChantas Mahaisavariya
Chantas Mahaisavariya
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
BMBanchong Mahaisavariya
Banchong Mahaisavariya
NCNattapon Chantarapanich
Nattapon Chantarapanich
Background: Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking. This study compared the biomechanical performance of three fixations for basicervical femoral neck fractures under torsion load during early ambulation. Methods: The biomechanical study models used three fixations: a DHS, a DHS with an anti-rotation screw, and a short CMN. Finite element analysis was used to simulate hip rotation with muscle forces related to leg swing applied to the femur. The equivalent von Mises stress (EQV) on fixation, fragment displacement, and strain energy density at the proximal cancellous bone were monitored for fixation stability. Results: The EQV of the short CMN construct (304.63 MPa) was comparable to that of the titanium DHS construct (293.39 MPa) and greater than that of the titanium DHS with an anti-rotation screw construct (200.94 MPa). The proximal fragment displacement in the short CMN construct was approximately 0.13 mm, the greatest among the constructs. The risk of screw cutout for the lag screw in short CMNs was 3.1–5.8 times greater than that for DHSs and DHSs with anti-rotation screw constructs. Conclusions: Titanium DHS combined with an anti-rotation screw provided lower fragment displacement, stress, and strain energy density in the femoral head than the other fixations under torsion load. Basicervical femoral neck fracture treated with CMNs may increase the risk of lag screw cutout. Graphical

1 April 2022 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Closed access
PDF file
SJS. Jitprapaikulsarn
S. Jitprapaikulsarn
NCNattapon Chantarapanich
Nattapon Chantarapanich
AGA. Gromprasit
A. Gromprasit
CMC. Mahaisavariya
C. Mahaisavariya
CPC. Patamamongkonchai
C. Patamamongkonchai

10 December 2023 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
NCNattapon Chantarapanich
Nattapon Chantarapanich
TATheerachai Apivatthakakul
Theerachai Apivatthakakul
AGArthit Gromprasit
Arthit Gromprasit
PLPasin Lertvilai
Pasin Lertvilai
CMChantas Mahaisavariya
Chantas Mahaisavariya