Surasak Jitprapaikulsarn

Surasak Jitprapaikulsarn

Auto-generated profile, based on publicly available information

Surasak Jitprapaikulsarn

Department of Orthopedics, Buddhachinaraj Hospital, Phitsanulok, Thailand

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
NNNutdanai Neti
Nutdanai Neti
WTWitoon Thremthakanpon
Witoon Thremthakanpon
AGArthit Gromprasit
Arthit Gromprasit

22 June 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CMChantas Mahaisavariya
Chantas Mahaisavariya
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
BMBanchong Mahaisavariya
Banchong Mahaisavariya
NCNattapon Chantarapanich
Nattapon Chantarapanich
Background: Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking. This study compared the biomechanical performance of three fixations for basicervical femoral neck fractures under torsion load during early ambulation. Methods: The biomechanical study models used three fixations: a DHS, a DHS with an anti-rotation screw, and a short CMN. Finite element analysis was used to simulate hip rotation with muscle forces related to leg swing applied to the femur. The equivalent von Mises stress (EQV) on fixation, fragment displacement, and strain energy density at the proximal cancellous bone were monitored for fixation stability. Results: The EQV of the short CMN construct (304.63 MPa) was comparable to that of the titanium DHS construct (293.39 MPa) and greater than that of the titanium DHS with an anti-rotation screw construct (200.94 MPa). The proximal fragment displacement in the short CMN construct was approximately 0.13 mm, the greatest among the constructs. The risk of screw cutout for the lag screw in short CMNs was 3.1–5.8 times greater than that for DHSs and DHSs with anti-rotation screw constructs. Conclusions: Titanium DHS combined with an anti-rotation screw provided lower fragment displacement, stress, and strain energy density in the femoral head than the other fixations under torsion load. Basicervical femoral neck fracture treated with CMNs may increase the risk of lag screw cutout. Graphical

22 May 2021 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
KSKritsada Sukha
Kritsada Sukha
CPChawanan Patamamongkonchai
Chawanan Patamamongkonchai
AGArthit Gromprasit
Arthit Gromprasit
WTWitoon Thremthakanpon
Witoon Thremthakanpon

29 March 2022 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
AGArthit Gromprasit
Arthit Gromprasit
KSKritsada Sukha
Kritsada Sukha
CPChawanan Patamamongkonchai
Chawanan Patamamongkonchai
CJChittawee Jiamton
Chittawee Jiamton

31 December 2024 in Injury
Verified
Journal Article
Closed access
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
NCNattapon Chantarapanich
Nattapon Chantarapanich
TATheerachai Apivatthakakul
Theerachai Apivatthakakul
PLPasin Lertvilai
Pasin Lertvilai
SWSujin Wanchat
Sujin Wanchat
CMChantas Mahaisavariya
Chantas Mahaisavariya

5 September 2020 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
SJSurasak Jitprapaikulsarn
Surasak Jitprapaikulsarn
CPChawanan Patamamongkonchai
Chawanan Patamamongkonchai
AGArthit Gromprasit
Arthit Gromprasit
WTWitoon Thremthakanpon
Witoon Thremthakanpon