Frances Pick

Dr. Frances Pick

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Water Research
Verified
Journal Article
Open access
FPFrances Pick
Frances Pick
KFKatherine E. Fish
Katherine E. Fish
JBJoby Boxall
Joby Boxall
A new conceptual model to describe and understand the role of assimilable organic carbon (AOC) within drinking water distribution systems is proposed. The impact of AOC on both drinking water biofilm and water quality was studied using bespoke pipe loop experimental facilities installed at three carefully selected operational water treatment works. Integrated physical, chemical and biological monitoring was undertaken that highlights the central role of biofilms in AOC cycling, forming the basis of the new conceptual model. Biofilms formed under high AOC conditions were found to pose the highest discoloration response, generating a turbidity (4.3 NTU) and iron (241.5 µg/l) response sufficient to have caused regulatory failures from only 20 m of pipe in only 12 months of operation. This new knowledge of the role of biofilms in AOC cycling, and ultimately impacts on water quality, can be used to inform management and help ensure the supply of high-quality, biostable drinking water.

6 December 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FPFrances Pick
Frances Pick
KFKatherine Fish
Katherine Fish
CBCatherine A Biggs
Catherine A Biggs
JMJonathan P Moses
Jonathan P Moses
GMGraeme Moore
Graeme Moore
JBJoby Boxall
Joby Boxall
Assimilable organic carbon (AOC) is known to correlate with microbial growth, which can consequently degrade drinking water quality. Despite this, there is no standardised AOC test that can be applied to drinking water distribution systems (DWDS). Herein we report the development of a quick, robust AOC that incorporates known strains Pseudomonas fluorescens strain P-17 and Spirillum strain NOX, a higher inoculum volume and enumeration using flow cytometry to generate a quicker (total test time reduced from 14 to 8 days), robust method. We apply the developed AOC test to twenty drinking water treatment works (WTW) to validate the method reproducibility and resolution across a wide range of AOC concentrations. Subsequently, AOC was quantified at 32 sample points, over four DWDS, for a year in order to identify sinks and sources of AOC in operative networks. Application of the developed AOC protocol provided a previously unavailable insight and novel evidence of pipes and service reservoirs exhibiting different AOC and regrowth behaviour. Observed correlations between AOC and microbial growth highlight the importance of monitoring AOC as an integral part of managing drinking water quality at the consumers tap.

28 October 2021 in Frontiers in Microbiology
Verified
Journal Article
Open access
FPFrances Pick
Frances Pick
KFKatherine E. Fish
Katherine E. Fish
SHStewart Husband
Stewart Husband
JBJoby B. Boxall
Joby B. Boxall
Biofilms are endemic in drinking water distribution systems (DWDS), forming on all water and infrastructure interfaces. They can pose risks to water quality and hence consumers. Our understanding of these biofilms is limited, in a large part due to difficulties in sampling them without unacceptable disruption. A novel, non-destructive and non-disruptive biofilm monitoring device (BMD), which includes use of flow cytometry analysis, was developed to assess biofouling rates. Laboratory based experiments established optimal configurations and verified reliable cell enumeration. Deployment at three operational field sites validated assessment of different biofouling rates. These differences in fouling rates were not obvious from bulk water sampling and analysis, but did have a strong correlation with long-term performance data of the associated networks. The device offers the potential to assess DWDS performance in a few months, compared to the number of years required to infer findings from historical customer contact data. Such information is vital to improve the management of our vast, complex and uncertain drinking water supply systems; for example rapidly quantifying the benefits of improvements in water treatment works or changes to maintenance of the network.

11 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JPJiwon Park
Jiwon Park
FPFrances Pick
Frances Pick
KFKatherine Fish
Katherine Fish
DQDominic Quinn
Dominic Quinn
CSCINDY JANE SMITH
CINDY JANE SMITH
JBJoby Boxall
Joby Boxall
The present study explored the incorporation of health-related organisms within drinking water biofilms and bulk water quality using benchtop-scale distribution systems. The annular reactors simulated the dead-end pipes of distribution systems with low shear stress but maintained a chlorine residual and formed young biofilms on plastic surfaces. Spiked coliforms and Escherichia coli were introduced to the annular reactors after 1 month of growth. Although initially detected in the spike, the coliforms were inactivated in the bulk water phase, likely due to environmental stresses, such as nutrient starvation and residual chlorine. Also, coliform incorporation within biofilm was only detected in a single coupon in the reactor 24 h post-spike (with 100% lake water), suggesting they were not incorporated or under the detection limit.

28 June 2024 in Water
Verified
Journal Article
Open access
PDF file
MPMichael Pointl
Michael Pointl
JMJoao Marques
Joao Marques
FPFrances Pick
Frances Pick
CSCamilo Salcedo
Camilo Salcedo
IVIna Vertommen
Ina Vertommen
KLKevin E. Lansey
Kevin E. Lansey
Historically, water utilities have relied on tried-and-true practices in the design and operation of their infrastructure, tapping new resources and expanding networks as needed. However, as the effects of climate change and/or urbanization increasingly impact both water supply and demand, utilities need new, holistic planning and management approaches. Integrated planning approaches must account for changing policies, technological progress, and unique, setting-specific operating conditions. Based on this notion, an international web seminar with faculty, researchers, and students from nine universities across five continents was conducted. In the 3-month seminar, participants were split into groups and tasked with developing future-proof, sustainable water management solutions for fictitious settings with unique resource availability, climate change predictions, demographic, and socioeconomic constraints. The goal of the seminar was to combine participants’ unique perspectives to tackle challenges in developing future water infrastructure, while forming lasting relationships. Water management concepts became more daring or “out-of-the-box” as the seminar progressed. Most groups opted for a holistic approach, optimizing existing infrastructure, integrating decentralized water management, furthering digitization, and fostering the adoption of innovative policy and planning strategies. To gauge their impact on the evolution of ideas, group dynamics and communication were observed throughout the seminar. As a result, the findings serve not only as a compendium of ideas and concepts for holistic design in the water sector, but also facilitate international collaboration, improve communication in cross-cultural teams or guide the development of training programs in water management for researchers, professional engineers, or water utilities.

14 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
DBDinesh Singh Bhandari
Dinesh Singh Bhandari
DQDominic Quinn
Dominic Quinn
ETErifyli Tsagkari
Erifyli Tsagkari
KFKatherine Fish
Katherine Fish
FPFrances Pick
Frances Pick
WSWilliam T. Sloan
William T. Sloan
The accumulation, growth, and re-mobilization of pathogens on the pipe walls in drinking water distribution systems are processes that affect the risk of exposure at the tap. We present a model that uses the Buckingham Pi theory to embody the physics of Pseudomonas aeruginosa accumulation and move within the system. We apply it to model experimental data from a biofilm annular reactor operated in conditions that are commensurate with the flow in DWDS. By calibrating the model for this benchtop system, we intend to identify the most important physical parameters for use in a simpler, more prudent model, for application in large-scale DWDS.