Chengchen Zhou

Mr. Chengchen Zhou


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JNJiucheng Nie
Jiucheng Nie
Yukun WangYukun Wang
Yukun Wang
DWDacheng Wang
Dacheng Wang
YDYue Ding
Yue Ding
CZChengchen Zhou
Chengchen Zhou
Xiaokun WangXiaokun Wang
Xiaokun Wang
This study examines the measurement of film thickness, curvature, and defects on the surface or inside of an optical element using a highly accurate and efficient method. This is essential to ensure their quality and performance. Existing methods are unable to simultaneously extract the three types of information: thickness, curvature, and defects. Spectral-domain optical coherence tomography (SD-OCT), a non-invasive imaging technique with imaging depths down to the millimeter scale, provides the possibility of detecting the optical element components’ parameters. In this paper, we propose an error correction model for compensating delay differences in A-scan, field curvature, and aberration to improve the accuracy of system fitting measurements using SD-OCT. During data processing, we use the histogram-equalized gray stretching (IAH-GS) method to deal with strong reflections in the thin film layers inside the optics using individual A-scan averages. In addition, we propose a window threshold cutoff algorithm to accurately identify defects and boundaries in OCT images. Finally, the system is capable of rapidly detecting the thickness and curvature of film layers in optical elements with a maximum measurement depth of 4.508 mm, a diameter of 15 × 15 mm, a resolution of 5.69 microns, and a sampling rate of 70 kHz. Measurements were performed on different standard optical elements to verify the accuracy and reliability of the proposed method. To the best of our knowledge, this is the first time that thickness, curvature, and defects of an optical film have been measured simultaneously, with a thickness measurement accuracy of 1.924 µm, and with a difference between the calibrated and nominal curvature measurements consistently within 1%. We believe that this research will greatly advance the use of OCT technology in the testing of optical thin films, thereby improving productivity and product quality.

13 August 2024 in Photonics
Verified
Journal Article
Open access
PDF file
QWQiong Qiong Wu
Qiong Qiong Wu
Xiaokun WangXiaokun Wang
Xiaokun Wang
SZShuangshuang Zhang
Shuangshuang Zhang
WLWenhan Li
Wenhan Li
YZYingjing Zhao
Yingjing Zhao
XZXuejun Zhang
Xuejun Zhang
Traditional methods for testing aspheric optical lenses struggle to achieve point-by-point testing across the full aperture of the lens. To facilitate the full-aperture, high-precision, and rapid testing of aspheric optical lenses, a power testing method of lenses based on the transmission phase deflectometric technique was employed. This method determines the phase deviation of light caused by the lens, thereby fitting the transmission wavefront and quickly detecting the power distribution information of the lens. This paper constructs a power testing model based on the phase deflectometric technique, proposes a calibration method that combines DLT (direct linear transformation) and pinhole models to reduce system errors, and combines phase extraction and wavefront fitting for experimental verification. The experimental results are compared with those obtained from the commercial visual lens mapper (VM-2000). The central errors of spherical power and cylindrical power are 1% and 0.7%, respectively. This provides a reliable method for the full-aperture, high-precision, and rapid testing of aspheric optical lenses.