Samuel W King

Mr. Samuel W King

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Lymphatic Research and Biology
Verified
Journal Article
Closed access
ASAmy R. Sharkey
Amy R. Sharkey
SKSamuel W King
Samuel W King
RKRachel Y. Kuo
Rachel Y. Kuo
SBShixin B. Bickerton
Shixin B. Bickerton
ARAlexander J. Ramsden
Alexander J. Ramsden
DFDominic Furniss
Dominic Furniss
Background: Accurate limb volume measurement is key in the assessment of outcomes in lymphedema microsurgery. There are two commonly used methods as follows: manual circumferential measurement (tape) or Perometer measurement. There are no data on the intra- and interclass correlation of either method, making it difficult to establish a gold standard of limb volume measurement. We aim to assess the intra- and interclass correlation of each method to establish the most appropriate method for clinical practice and future research studies, aiming to compare the accuracy and reliability of tape measurement as assessed against Perometer measurement. Methods and Results: Student volunteers and experts (lymphedema practitioners) were each asked to perform repeat tape and Perometer measurements on the upper or lower limb of one healthy volunteer. Perometer measurements were globally more accurate than tape (average SE [Perometer]: 23.23 vs. 77.21 [tape]). For intraobserver reliability, experts outperformed students in all domains tested, with little difference in intraobserver reliability using tape or Perometer (average Cronbach's alpha 0.9597 [expert)] vs. 0.6033 [student]). Conclusions: We recommend that, for increased interobserver reliability, the Perometer provides a more reliable standard of limb volume measurement.

25 June 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
JLJ.N. Lamb
J.N. Lamb
SJS. Jain
S. Jain
SKSamuel W King
Samuel W King
RWRobert Michael West
Robert Michael West
HPHemant G. Pandit
Hemant G. Pandit
Background: Total hip replacement (THR) with a cemented polished taper-slip (PTS) femoral stem has excellent long-term results but is associated with a higher postoperative periprosthetic femoral fracture (PFF) risk compared with composite beam stems. This study aimed to identify risk factors associated with PFF revision following THR with PTS stems. Methods: In a retrospective cohort study, 299,019 primary THRs using PTS stems from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) were included, with a median follow-up of 5.2 years (interquartile range [IQR], 3.1 to 8.2 years). The adjusted hazard ratio (HR) of PFF revision was estimated for each variable using multivariable Cox survival regression analysis. Results: Of 299,019 THR cases, 1,055 underwent revision for PFF at a median time of 3.1 years (IQR, 1.0 to 6.1 years). The mean age (and standard deviation) was 72 ± 9.7 years, 64.3% (192,365 patients) were female, and 82.6% (247,126 patients) had an American Society of Anesthesiologists (ASA) class of 1 or 2. Variables associated with increased PFF were increasing age (HR, 1.02 per year), intraoperative fracture (HR, 2.57 [95% confidence interval (CI), 1.42 to 4.66]), ovaloid (HR, 1.96 [95% CI, 1.22 to 3.16]) and round cross-sectional shapes (HR, 9.58 [95% CI, 2.29 to 40.12]), increasing stem offset (HR, 1.07 per millimeter), increasing head size (HR, 1.04 per millimeter), THR performed from 2012 to 2016 (HR, 1.45 [95% CI, 1.18 to 1.78]), cobalt-chromium stem material (HR, 6.7 [95% CI, 3.0 to 15.4]), and cobalt-chromium stems with low-viscosity cement (HR, 22.88 [95% CI, 9.90 to 52.85]). Variables associated with a decreased risk of PFF revision were female sex (HR, 0.52 [95% CI, 0.45 to 0.59]), increasing stem length (HR, 0.97 per millimeter), and a ceramic-on-polyethylene bearing (HR, 0.55 [95% CI, 0.36 to 0.85]). Conclusions: Increased risk of PFF revision was associated with PTS stems that are short, have high offset, are used with large femoral heads, are made of cobalt-chromium, or have ovaloid or round cross-sectional shapes. Large increases in PFF risk were associated with cobalt-chromium stems used with low-viscosity cement. Further study is required to confirm causation. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

23 September 2016 in Microsurgery
Verified
Journal Article
Closed access
PDF file
ASAmy R. Sharkey
Amy R. Sharkey
SKSamuel W King
Samuel W King
ARAlexander J. Ramsden
Alexander J. Ramsden
DFDominic Furniss
Dominic Furniss

28 December 2022 in Indian Journal of Orthopaedics
Verified
Journal Article
Open access
PDF file
EKEdgars Kelmers
Edgars Kelmers
ASAgata Szuba
Agata Szuba
SKSamuel W King
Samuel W King
JPJeya Palan
Jeya Palan
SFSteven Freear
Steven Freear
BDBernard H. van Duren
Bernard H. van Duren
Background: This article focuses on clinical implementation of smart knee implants for total knee replacement and the future development of smart implant technology. With the number of total knee replacements undertaken growing worldwide, smart implants incorporating embedded sensor technology offer opportunity to improve post-operative recovery, reducing implant failure rates, and increasing overall patient satisfaction. Methods: A literature review on smart implants, historical prototypes, current clinically available smart implants, and the future potential for conventional implant instrumentation with embedded sensors and electronics was undertaken. Results: The overview of current and future technology describes use cases for various diagnostic and therapeutic treatment solutions. Conclusion: Smart knee implants are at an early development stage, with the first generation of smart implants being available to patients and with more novel technologies under development.

1 November 2018 in Maturitas
Verified
Journal Article
Open access
SKSamuel W King
Samuel W King
JLJonathan N. Lamb
Jonathan N. Lamb
ECEmily S. Cage
Emily S. Cage
HPHemant Pandit
Hemant Pandit
Total joint arthroplasties are increasing worldwide in both frequency and prevalence. When successful, they offer great improvements in quality of life. However, fractures around implants are often difficult to manage and require prolonged inpatient stays in tertiary hospitals. Management may differ between surgeons, but most patients will be managed surgically if mobility or joint stability is threatened. Those affected are often at higher risk from surgery, are frailer and at higher risk of mortality and a lifelong reduction in mobility. The incidence of these fractures is increasing, and patients should appreciate the risk and implications of this recognised complication of joint arthroplasty.

12 December 2022 in Indian Journal of Orthopaedics
Verified
Journal Article
Closed access
PDF file
SKSamuel W King
Samuel W King
MEMomin Eltayeb
Momin Eltayeb
BDBernard H. van Duren
Bernard H. van Duren
SJSameer Jain
Sameer Jain
JKJoel Kerry
Joel Kerry
JPJeya Palan
Jeya Palan