Steven Freear

Prof. Steven Freear

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Additive Manufacturing
Verified
Journal Article
Closed access
MAMeisam Askari
Meisam Askari
DHDavid A. Hutchins
David A. Hutchins
PTPeter J. Thomas
Peter J. Thomas
LALorenzo Astolfi
Lorenzo Astolfi
WRWatson Richard
Watson Richard
ACAdam T. Clare
Adam T. Clare

6 June 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Enrico BoniEnrico Boni
Enrico Boni
AYAlfred Yu
Alfred Yu
SFSteven Freear
Steven Freear
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Piero TortoliPiero Tortoli
Piero Tortoli
Open platform (OP) ultrasound systems are aimed primarily at the research community. They have been at the forefront of the development of synthetic aperture, plane wave, shear wave elastography, and vector flow imaging. Such platforms are driven by a need for broad flexibility of parameters that are normally preset or fixed within clinical scanners. OP ultrasound scanners are defined to have three key features including customization of the transmit waveform, access to the prebeamformed receive data, and the ability to implement real-time imaging. In this paper, a formative discussion is given on the development of OPs from both the research community and the commercial sector. Both software- and hardware-based architectures are considered, and their specifications are compared in terms of resources and programmability. Software-based platforms capable of real-time beamforming generally make use of scalable graphics processing unit architectures, whereas a common feature of hardware-based platforms is the use of field-programmable gate array and digital signal processor devices to provide additional on-board processing capacity. OPs with extended number of channels (>256) are also discussed in relation to their role in supporting 3-D imaging technique development. With the increasing maturity of OP ultrasound scanners, the pace of advancement in ultrasound imaging algorithms is poised to be accelerated.

21 November 2012 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
PSPaschalis C. Sofotasios
Paschalis C. Sofotasios
EREric Rebeiz
Eric Rebeiz
LZLi Zhang
Li Zhang
TTTheodoros A. Tsiftsis
Theodoros A. Tsiftsis
DCDanijela Cabric
Danijela Cabric
SFSteven Freear
Steven Freear
Energy detection (ED) is a simple and popular method of spectrum sensing in cognitive radio systems. It is also widely known that the performance of sensing techniques is largely affected when users experience fading effects. This paper investigates the performance of an energy detector over generalized κ-μ and κ- μ extreme fading channels, which have been shown to provide remarkably accurate fading characterization. Novel analytic expressions are firstly derived for the corresponding average probability of detection for the case of single-user detection. These results are subsequently extended to the case of square-law selection (SLS) diversity and for collaborative detection scenarios. As expected, the performance of the detector is highly dependent upon the severity of fading since even small variations of the fading conditions affect significantly the value of the average probability of detection. Furthermore, the performance of the detector improves substantially as the number of branches or collaborating users increase in both severe and moderate fading conditions, whereas it is shown that the κ- μ extreme model is capable of accounting for fading variations even at low signal-to-noise values. The offered results are particularly useful in assessing the effect of fading in ED-based cognitive radio communication systems; therefore, they can be used in quantifying the associated tradeoffs between sensing performance and energy efficiency in cognitive radio networks.

30 September 2010 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DCDavid M.J. Cowell
David M.J. Cowell
SFSteven Freear
Steven Freear
Linear frequency modulated (LFM) excitation combined with pulse compression provides an increase in SNR at the receiver. LFM signals are of longer duration than pulsed signals of the same bandwidth; consequently, in many practical situations, maintaining temporal separation between echoes is not possible. Where analysis is performed on individual LFM signals, a separation technique is required. Time windowing is unable to separate signals overlapping in time. Frequency domain filtering is unable to separate signals with overlapping spectra. This paper describes a method to separate time-overlapping LFM signals through the application of the fractional Fourier transform (FrFT), a transform operating in both time and frequency domains. A short introduction to the FrFT and its operation and calculation are presented. The proposed signal separation method is illustrated by application to a simulated ultrasound signal, created by the summation of multiple time-overlapping LFM signals and the component signals recovered with ±0.6% spectral error. The results of an experimental investigation are presented in which the proposed separation method is applied to time-overlapping LFM signals created by the transmission of a LFM signal through a stainless steel plate and water-filled pipe.

29 August 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SPSally A. Peyman
Sally A. Peyman
RARadwa H. Abou-Saleh
Radwa H. Abou-Saleh
JMJames R. McLaughlan
James R. McLaughlan
NINicola Ingram
Nicola Ingram
BJBenjamin R. G. Johnson
Benjamin R. G. Johnson
SEStephen D Evans
Stephen D Evans
Micron sized, lipid stabilized bubbles of gas are of interest as contrast agents for ultra-sound (US) imaging and increasingly as delivery vehicles for targeted, triggered, therapeutic delivery. Microfluidics provides a reproducible means for microbubble production and surface functionalisation. In this study, microbubbles are generated on chip using flow-focussing microfluidic devices that combine streams of gas and liquid through a nozzle a few microns wide and then subjecting the two phases to a downstream pressure drop. While microfluidics has successfully demonstrated the generation of monodisperse bubble populations, these approaches inherently produce low bubble counts. We introduce a new micro-spray flow regime that generates consistently high bubble concentrations that are more clinically relevant compared to traditional monodisperse bubble populations. Final bubble concentrations produced by the micro-spray regime were up to 1010 bubbles mL−1. The technique is shown to be highly reproducible and by using multiplexed chip arrays, the time taken to produce one millilitre of sample containing 1010 bubbles mL−1 was ∼10 min. Further, we also demonstrate that it is possible to attach liposomes, loaded with quantum dots (QDs) or fluorescein, in a single step during MBs formation.

15 December 2015 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
SPSally A. Peyman
Sally A. Peyman
JMJames R. McLaughlan
James R. McLaughlan
RARadwa H. Abou-Saleh
Radwa H. Abou-Saleh
GMGemma Marston
Gemma Marston
BJBenjamin R. G. Johnson
Benjamin R. G. Johnson
SEStephen D Evans
Stephen D Evans
Micron-sized lipid-stabilised bubbles of heavy gas have been utilised as contrast agents for diagnostic ultrasound (US) imaging for many years. Typically bubbles between 1 and 8 μm in diameter are produced to enhance imaging in US by scattering sound waves more efficiently than surrounding tissue. A potential area of interest for Contrast Enhanced Ultrasound (CEUS) are bubbles with diameters <1 μm or ‘nanobubbles.’ As bubble diameter decreases, ultrasonic resonant frequency increases, which could lead to an improvement in resolution for high-frequency imaging applications when using nanobubbles. In addition, current US contrast agents are limited by their size to the vasculature in vivo. However, molecular-targeted nanobubbles could penetrate into the extra-vascular space of cancerous tissue providing contrast in regions inaccessible to traditional microbubbles. This paper reports a new microfluidic method for the generation of sub-micron sized lipid stabilised particles containing perfluorocarbon (PFC). The nanoparticles are produced in a unique atomisation-like flow regime at high production rates, in excess of 106 particles per s and at high concentration, typically >1011 particles per mL. The average particle diameter appears to be around 100–200 nm. These particles, suspected of being a mix of liquid and gaseous C4F10 due to Laplace pressure, then phase convert into nanometer sized bubbles on the application of US. In vitro ultrasound characterisation from these nanoparticle populations showed strong backscattering compared to aqueous filled liposomes of a similar size. The nanoparticles were stable upon injection and gave excellent contrast enhancement when used for in vivo imaging, compared to microbubbles with an equivalent shell composition.