Javier Garcia-Casado

Dr. Javier Garcia-Casado

Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
YYYiyao Ye-Lin
Yiyao Ye-Lin
GPGema Prats-Boluda
Gema Prats-Boluda
JMJavier Mas-Cabo
Javier Mas-Cabo
Jose Alberola-RubioJose Alberola-Rubio
Jose Alberola-Rubio
APAlfredo Perales
Alfredo Perales
Preterm birth (PTB) is one of the most common and serious complications in pregnancy. About 15 million preterm neonates are born every year, with ratios of 10–15% of total births. In industrialized countries, preterm delivery is responsible for 70% of mortality and 75% of morbidity in the neonatal period. Diagnostic means for its timely risk assessment are lacking and the underlying physiological mechanisms are unclear. Surface recording of the uterine myoelectrical activity (electrohysterogram, EHG) has emerged as a better uterine dynamics monitoring technique than traditional surface pressure recordings and provides information on the condition of uterine muscle in different obstetrical scenarios with emphasis on predicting preterm deliveries. Objective : A comprehensive review of the literature was performed on studies related to the use of the electrohysterogram in the PTB context. Approach : This review presents and discusses the results according to the different types of parameter (temporal and spectral, non-linear and bivariate) used for EHG characterization. Main results : Electrohysterogram analysis reveals that the uterine electrophysiological changes that precede spontaneous preterm labor are associated with contractions of more intensity, higher frequency content, faster and more organized propagated activity and stronger coupling of different uterine areas. Temporal, spectral, non-linear and bivariate EHG analyses therefore provide useful and complementary information. Classificatory techniques of different types and varying complexity have been developed to diagnose PTB. The information derived from these different types of EHG parameters, either individually or in combination, is able to provide more accurate predictions of PTB than current clinical methods. However, in order to extend EHG to clinical applications, the recording set-up should be simplified, be less intrusive and more robust—and signal analysis should be automated without requiring much supervision and yield physiologically interpretable results. Significance : This review provides a general background to PTB and describes how EHG can be used to better understand its underlying physiological mechanisms and improve its prediction. The findings will help future research workers to decide the most appropriate EHG features to be used in their analyses and facilitate future clinical EHG applications in order to improve PTB prediction.

1 January 2014 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
GPGema Prats-Boluda
Gema Prats-Boluda
JAJosé Alberola-Rubio
José Alberola-Rubio
APAlfredo Perales
Alfredo Perales
Electrohysterography (EHG) is a noninvasive technique for monitoring uterine electrical activity. However, the presence of artifacts in the EHG signal may give rise to erroneous interpretations and make it difficult to extract useful information from these recordings. The aim of this work was to develop an automatic system of segmenting EHG recordings that distinguishes between uterine contractions and artifacts. Firstly, the segmentation is performed using an algorithm that generates the TOCO-like signal derived from the EHG and detects windows with significant changes in amplitude. After that, these segments are classified in two groups: artifacted and nonartifacted signals. To develop a classifier, a total of eleven spectral, temporal, and nonlinear features were calculated from EHG signal windows from 12 women in the first stage of labor that had previously been classified by experts. The combination of characteristics that led to the highest degree of accuracy in detecting artifacts was then determined. The results showed that it is possible to obtain automatic detection of motion artifacts in segmented EHG recordings with a precision of 92.2% using only seven features. The proposed algorithm and classifier together compose a useful tool for analyzing EHG signals and would help to promote clinical applications of this technique.

16 August 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JAJ. Alberola-Rubio
J. Alberola-Rubio
GPGema Prats-Boluda
Gema Prats-Boluda
YYY. Ye-Lin
Y. Ye-Lin
JVJ. Valero
J. Valero
APA. Perales
A. Perales
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Non-invasive recording of uterine myoelectric activity (electrohysterogram, EHG) could provide an alternative to monitoring uterine dynamics by systems based on tocodynamometers (TOCO). Laplacian recording of bioelectric signals has been shown to give better spatial resolution and less interference than mono- and bipolar surface recordings. The aim of this work was to study the signal quality obtained from monopolar, bipolar and Laplacian techniques in EHG recordings, as well as to assess their ability to detect uterine contractions. Twenty-two recording sessions were carried out on singleton pregnant women during the active phase of labour. In each session the following simultaneous recordings were obtained: internal uterine pressure (IUP), external tension of abdominal wall (TOCO) and EHG signals (5 monopolar and 4 bipolar recordings, 1 discrete approximation to the Laplacian of the potential and 2 estimates of the Laplacian from two active annular electrodes). The results obtained show that EHG is able to detect a higher number of uterine contractions than TOCO. Laplacian recordings give improved signal quality over monopolar and bipolar techniques, reduce maternal cardiac interference and improve the signal-to-noise ratio. The optimal position for recording EHG was found to be the uterine median axis and the lower centre-right umbilical zone.

8 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JMJavier Mas
Javier Mas
GPGema Prats-Boluda
Gema Prats-Boluda
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Jose Alberola-RubioJose Alberola-Rubio
Jose Alberola-Rubio
IMIsauro Rogelio Monfort-Ortiz
Isauro Rogelio Monfort-Ortiz
YYYiyao Ye-Lin
Yiyao Ye-Lin
Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy and entails high costs for health systems. Currently, no reliable labor proximity prediction techniques are available for clinical use. Regular checks by uterine electrohysterogram (EHG) for predicting preterm labor have been widely studied. The aim of the present study was to assess the feasibility of predicting labor with a 7- and 14-day time horizon in TPL women, who may be under tocolytic treatment, using EHG and/or obstetric data. Based on 140 EHG recordings, artificial neural networks were used to develop prediction models. Non-linear EHG parameters were found to be more reliable than linear for differentiating labor in under and over 7/14 days. Using EHG and obstetric data, the <7- and <14-day labor prediction models achieved an AUC in the test group of 87.1 ± 4.3% and 76.2 ± 5.8%, respectively. These results suggest that EHG can be reliable for predicting imminent labor in TPL women, regardless of the tocolytic therapy stage. This paves the way for the development of diagnostic tools to help obstetricians make better decisions on treatments, hospital stays and admitting TPL women, and can therefore reduce costs and improve maternal and fetal wellbeing.

1 February 2017 in Measurement
Verified
Journal Article
Closed access
YYY. Ye-Lin
Y. Ye-Lin
JBJ.M. Bueno-Barrachina
J.M. Bueno-Barrachina
GPGema Prats-Boluda
Gema Prats-Boluda
RSR. Rodriguez de Sanabria
R. Rodriguez de Sanabria
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado

16 May 2005 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
JMJ.L. Martinez-De-Juan
J.L. Martinez-De-Juan
JPJ.L. Ponce
J.L. Ponce
Intestinal myoelectrical activity (IMA), which determines bowel mechanical activity, is the result of two components: a low-frequency component [slow wave (SW)] that is always present, and a high-frequency component [spike bursts (SB)] which is associated with bowel contractions. Despite of the diagnostic significance of internal recordings of IMA, clinical application of this technique is limited due to its invasiveness. Thus, surface recording of IMA which is also called electroenterogram (EEnG) could be a solution for noninvasive monitoring of intestinal motility. The aim of our work was to identify slow wave and spike burst activity on surface EEnG in order to quantify bowel motor activity. For this purpose, we conducted simultaneous recordings of IMA in bowel serosa and on abdominal surface of five Beagle dogs in fast state. Surface EEnG was studied in spectral domain and frequency bands for slow wave and spike burst energy were determined. Maximum signal-to-interference ratio (7.5dB/spl plusmn/36%) on SB frequency band was obtained when reducing upper frequency limit of signal analysis. Energy of external EEnG in reduced SB frequency band (2-7.9Hz) presented a high correlation (0.71/spl plusmn/7%) with internal intensity of contractions. Our results suggest that energy of SB can be quantified on external EEnG which could provide a noninvasive method for monitoring intestinal mechanical activity.