Yiyao Ye-Lin

Prof. Yiyao Ye-Lin


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
YYYiyao Ye-Lin
Yiyao Ye-Lin
GPGema Prats-Boluda
Gema Prats-Boluda
JMJavier Mas-Cabo
Javier Mas-Cabo
Jose Alberola-RubioJose Alberola-Rubio
Jose Alberola-Rubio
APAlfredo Perales
Alfredo Perales
Preterm birth (PTB) is one of the most common and serious complications in pregnancy. About 15 million preterm neonates are born every year, with ratios of 10–15% of total births. In industrialized countries, preterm delivery is responsible for 70% of mortality and 75% of morbidity in the neonatal period. Diagnostic means for its timely risk assessment are lacking and the underlying physiological mechanisms are unclear. Surface recording of the uterine myoelectrical activity (electrohysterogram, EHG) has emerged as a better uterine dynamics monitoring technique than traditional surface pressure recordings and provides information on the condition of uterine muscle in different obstetrical scenarios with emphasis on predicting preterm deliveries. Objective : A comprehensive review of the literature was performed on studies related to the use of the electrohysterogram in the PTB context. Approach : This review presents and discusses the results according to the different types of parameter (temporal and spectral, non-linear and bivariate) used for EHG characterization. Main results : Electrohysterogram analysis reveals that the uterine electrophysiological changes that precede spontaneous preterm labor are associated with contractions of more intensity, higher frequency content, faster and more organized propagated activity and stronger coupling of different uterine areas. Temporal, spectral, non-linear and bivariate EHG analyses therefore provide useful and complementary information. Classificatory techniques of different types and varying complexity have been developed to diagnose PTB. The information derived from these different types of EHG parameters, either individually or in combination, is able to provide more accurate predictions of PTB than current clinical methods. However, in order to extend EHG to clinical applications, the recording set-up should be simplified, be less intrusive and more robust—and signal analysis should be automated without requiring much supervision and yield physiologically interpretable results. Significance : This review provides a general background to PTB and describes how EHG can be used to better understand its underlying physiological mechanisms and improve its prediction. The findings will help future research workers to decide the most appropriate EHG features to be used in their analyses and facilitate future clinical EHG applications in order to improve PTB prediction.

8 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JMJavier Mas
Javier Mas
GPGema Prats-Boluda
Gema Prats-Boluda
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Jose Alberola-RubioJose Alberola-Rubio
Jose Alberola-Rubio
IMIsauro Rogelio Monfort-Ortiz
Isauro Rogelio Monfort-Ortiz
YYYiyao Ye-Lin
Yiyao Ye-Lin
Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy and entails high costs for health systems. Currently, no reliable labor proximity prediction techniques are available for clinical use. Regular checks by uterine electrohysterogram (EHG) for predicting preterm labor have been widely studied. The aim of the present study was to assess the feasibility of predicting labor with a 7- and 14-day time horizon in TPL women, who may be under tocolytic treatment, using EHG and/or obstetric data. Based on 140 EHG recordings, artificial neural networks were used to develop prediction models. Non-linear EHG parameters were found to be more reliable than linear for differentiating labor in under and over 7/14 days. Using EHG and obstetric data, the <7- and <14-day labor prediction models achieved an AUC in the test group of 87.1 ± 4.3% and 76.2 ± 5.8%, respectively. These results suggest that EHG can be reliable for predicting imminent labor in TPL women, regardless of the tocolytic therapy stage. This paves the way for the development of diagnostic tools to help obstetricians make better decisions on treatments, hospital stays and admitting TPL women, and can therefore reduce costs and improve maternal and fetal wellbeing.

4 October 2023 in Heliyon
Verified
Journal Article
Open access
GGG. Gimenez-Aparisi
G. Gimenez-Aparisi
EGE. Guijarro-Estelles
E. Guijarro-Estelles
ACA. Chornet-Lurbe
A. Chornet-Lurbe
SBS. Ballesta-Martinez
S. Ballesta-Martinez
MPM. Pardo-Hernandez
M. Pardo-Hernandez
YYYiyao Ye-Lin
Yiyao Ye-Lin
While resting state electroencephalography (EEG) provides relevant information on pathological changes in Parkinson's disease, most studies focus on the eyes-closed EEG biomarkers. Recent evidence has shown that both eyes-open EEG and reactivity to eyes-opening can also differentiate Parkinson's disease from healthy aging, but no consensus has been reached on a discriminatory capability benchmark. The aim of this study was to determine the resting-state EEG biomarkers suitable for real-time application that can differentiate Parkinson's patients from healthy subjects under both eyes closed and open. For this, we analysed and compared the quantitative EEG analyses of 13 early-stage cognitively normal Parkinson's patients with an age and sex-matched healthy group. We found that Parkinson's disease exhibited abnormal excessive theta activity in eyes-closed, which was reflected by a significantly higher relative theta power, a higher time percentage with a frequency peak in the theta band and a reduced alpha/theta ratio, while Parkinson's patients showed a significantly steeper non-oscillatory spectral slope activity than that of healthy subjects. We also found considerably less alpha and beta reactivity to eyes-opening in Parkinson's disease plus a significant moderate correlation between these EEG-biomarkers and the MDS-UPDRS score, used to assesses the clinical symptoms of Parkinson's Disease. Both EEG recordings with the eyes open and reactivity to eyes-opening provided additional information to the eyes-closed condition.

10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Félix Nieto-del-AmorFélix Nieto-del-Amor
Félix Nieto-del-Amor
RBRaja Beskhani
Raja Beskhani
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
ADAlba Díaz
Alba Díaz
GPGema Prats-Boluda
Gema Prats-Boluda
One of the remaining challenges for the scientific-technical community is predicting preterm births, for which electrohysterography (EHG) has emerged as a highly sensitive prediction technique. Sample and fuzzy entropy have been used to characterize EHG signals, although they require optimizing many internal parameters. Both bubble entropy, which only requires one internal parameter, and dispersion entropy, which can detect any changes in frequency and amplitude, have been proposed to characterize biomedical signals. In this work, we attempted to determine the clinical value of these entropy measures for predicting preterm birth by analyzing their discriminatory capacity as an individual feature and their complementarity to other EHG characteristics by developing six prediction models using obstetrical data, linear and non-linear EHG features, and linear discriminant analysis using a genetic algorithm to select the features. Both dispersion and bubble entropy better discriminated between the preterm and term groups than sample, spectral, and fuzzy entropy. Entropy metrics provided complementary information to linear features, and indeed, the improvement in model performance by including other non-linear features was negligible. The best model performance obtained an F1-score of 90.1 ± 2% for testing the dataset. This model can easily be adapted to real-time applications, thereby contributing to the transferability of the EHG technique to clinical practice.


21 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
GPGema Prats-Boluda
Gema Prats-Boluda
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Eduardo Garcia-BreijoEduardo Garcia-Breijo
Eduardo Garcia-Breijo
Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.