Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the technique of choice in the study of mediastinal and hilar lesions; however, it can be affected by the insufficiency of intact biopsy samples, which might decrease its diagnostic yield for certain conditions, thus requiring re-biopsies or additional diagnostic procedures such as mediastinoscopy when the probability of malignancy remains high. Our objectives were to 1) attempt to reproduce this technique in the same conditions that we performed EBUS-TBNA,i.e.in the bronchoscopy suite and under moderate sedation; 2) describe the method used for its execution; 3) determine its feasibility by accessing different lymph node stations applying our method; and 4) analyse the diagnostic yield and its complications.Methods: This was a prospective study of 50 patients who underwent EBUS-TBNA and EBUS-guided transbronchial mediastinal cryobiopsy (TMC) in a single procedure using a 22-G TBNA needle and a 1.1-mm cryoprobe subsequently between January and August 2022. Patients with mediastinal lesions >1 cm were recruited, and EBUS-TBNA and TMC were performed in the same lymph node station.Results: The diagnostic yield was 82% and 96% for TBNA and TMC, respectively. Diagnostic yields were similar for sarcoidosis, while cryobiopsy was more sensitive than TBNA in lymphomas and metastatic lymph nodes. As for complications, there was no pneumothorax and in no case was there significant bleeding. There were no complications during the procedure or in the follow-up of these patients.Conclusions: TMC following our method is a minimally invasive, rapid and safe technique that can be performed in a bronchoscopy suite under moderate sedation, with a higher diagnostic yield than EBUS-TBNA, especially in cases of lymphoproliferative disorders and metastatic lymph nodes or when more biopsy sample is needed for molecular determinations.
Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images.
Background: Diaphragmatic ultrasound emerges as a valuable non-invasive method for assessing diaphragm functionality in patients with amyotrophic lateral sclerosis (ALS). This study aimed to evaluate diaphragmatic ultrasound parameters in ALS, compare them with respiratory function tests, and determine whether they are associated with the need for non-invasive ventilation (NIV). Methods: This was a prospective, descriptive, and multicenter study across five centers, enrolling patients with recent diagnoses of ALS. At three-monthly visits, participants underwent both diaphragmatic ultrasound and pulmonary function testing. The following variables were analyzed: withdrawal from this study due to NIV or death, excursion, velocity, thickness, thickening fraction, and spirometric and respiratory muscle function values. Results: A total of 41 patients were included. A total of 24 (61.5%) patients left this study before the final year: 17 due to initiation of NIV, 4 due to clinical deterioration without NIV, and 3 due to death. Statistically significant moderate correlations were observed between diaphragmatic excursion and velocity and FVC and supine FVC (p < 0.001) and with MIP and the SNIP test (p < 0.05). No correlation was observed with thickening fraction. Additionally, lower baseline values in excursion were significantly associated with study withdrawal, along with reduced lung function (FVC, supine FVC, and MEP (p < 0.001). Conclusions: assessing diaphragmatic excursion by ultrasonography may serve as a useful tool for monitoring patients with ALS.