Ramon Fernandez

Dr. Ramon Fernandez

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Archivos de Bronconeumología
Verified
Journal Article
Closed access
RFRamon Fernandez
Ramon Fernandez
CGCristina Martínez González
Cristina Martínez González
AMAida Quero Martínez
Aida Quero Martínez
JPJosé Jesús Blanco Pérez
José Jesús Blanco Pérez
LFLuis Carazo Fernández
Luis Carazo Fernández
AFAmador Prieto Fernández
Amador Prieto Fernández

1 September 2012 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
RFRamon Fernandez
Ramon Fernandez
CCCristina Cabrera
Cristina Cabrera
GRGemma Rubinos
Gemma Rubinos
APAna Pando
Ana Pando
RGRosa Galindo
Rosa Galindo
PCPere Casan
Pere Casan
INTRODUCTION: In home mechanical ventilation (HMV), the mask is a key factor for patient comfort and therapeutic adherence. There is no evidence on the best strategy for choosing the mask in HMV. OBJECTIVE: To explore patient preference when prescribing the mask for HMV treatment and assess its relationship with effectiveness. METHODS: A prospective study with repeated measures in stable patients receiving home nocturnal ventilation. Alternating oronasal mask (ONM) and nasal mask (NM) were tested in day and overnight sessions, with arterial blood gas measured and SpO2 monitored. At the end of each evening session, patients rated interface comfort using a visual analog scale. At 3 months we evaluated adherence and effectiveness of the treatment. RESULTS: Twenty-nine subjects (mean ± SD age 65 ± 13 y, 44% male) completed the study. Initial functional values were PCO2 57.4 ± 5.2 mm Hg and time with SpO2 < 90% (T90) 81.5 ± 9.5%. Both ONM and NM significantly decreased PCO2 and T90. Over a third (38%) of our subjects preferred ONM, while NM was deemed more comfortable in general. At 3 months, effectiveness and adherence showed no differences between those treated with NM or ONM. CONCLUSIONS: Patient choice is an effective criterion for selecting the interface in HMV treatment.

1 November 2014 in Archivos de Bronconeumología
Verified
Journal Article
Closed access
HRHerminia Buchelli Ramirez
Herminia Buchelli Ramirez
RFRamon Fernandez
Ramon Fernandez
GCGemma Rubinos Cuadrado
Gemma Rubinos Cuadrado
CGCristina Martinez Gonzalez
Cristina Martinez Gonzalez
FJFrancisco Rodriguez Jerez
Francisco Rodriguez Jerez
PCPere Casan Clara
Pere Casan Clara

27 September 2012 in Respiration
Verified
Journal Article
Closed access
PDF file
RFRamon Fernandez
Ramon Fernandez
GCGemma Rubinos Cuadrado
Gemma Rubinos Cuadrado
FJFrancisco Rodriguez Jerez
Francisco Rodriguez Jerez
AGAlmudena Garcia Garcia
Almudena Garcia Garcia
PMPatricia Rodriguez Menendez
Patricia Rodriguez Menendez
PCPere Casan Clara
Pere Casan Clara
Background: Leakage is common in patients receiving home mechanical ventilation (HMV) via a face mask. Although pressure ventilators have partial compensatory capacity, excessive leakage can compromise the effectiveness of treatment. Home ventilators are equipped with built-in software which provides information on leakage. However, the values of leakage and their effects in routine clinical practice are currently little known. Objective: To measure leakage in stable patients on nocturnal HMV and its impact on treatment effectiveness. Methods: Consecutive outpatients on HMV were recruited. Nocturnal pulse oximetry was performed at home and leakage was measured using the ventilator’s built-in software. We measured: mean SpO2, percentage of time with SpO2 <90% (T90), mean leakage (meanL), maximum leakage (maxL), and minimum leakage (minL) during the ventilation session. We estimated ventilator capacity to compensate for leakage according to inspiratory positive airway pressure and divided the patients into two groups: those with leak compensation and those without. Results: The study included 41 patients [mean age, 64 years (SD 11.9); 23 (56%) women]. Nocturnal pulse oximetry showed an SpO2 of 94% (±2.9) and a T90 of 10% (±21.7). Leakage (in l/min) was: meanL, 32.2 (±15.3); maxL, 64.8 (±28.5), and minL, 18.8 (±10.6). Seven cases (17%) had leakage greater than the ventilator compensatory capacity, but no significant difference in SpO2 or T90 was observed between patients with or without leak compensation. Conclusions: A wide variation between maxL and minL was observed in our series; 17% of cases had higher leakage values than the compensatory capacity of the ventilator, but this did not affect nocturnal oxygenation.

5 April 2016 in Lung
Verified
Journal Article
Closed access
PDF file
RFRamon Fernandez
Ramon Fernandez
GCGemma Rubinos Cuadrado
Gemma Rubinos Cuadrado
RARebeca Alonso-Arias
Rebeca Alonso-Arias
JHJuan Alejandro Cascón Hernández
Juan Alejandro Cascón Hernández
BABegoña Palomo Antequera
Begoña Palomo Antequera
PCPere Casan Clara
Pere Casan Clara

1 August 2009 in Archivos de Bronconeumología
Verified
Journal Article
Closed access
RFRamon Fernandez
Ramon Fernandez
GRGemma Rubinos-Cuadrado
Gemma Rubinos-Cuadrado
CCCristina Cabrera-Lacalzada
Cristina Cabrera-Lacalzada
RGRosa Galindo-Morales
Rosa Galindo-Morales
JGJosé Antonio Gullón-Blanco
José Antonio Gullón-Blanco
IGIsidro González-Martín
Isidro González-Martín