Jesper Hjortdal

Dr. Jesper Hjortdal


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AHAnders Hvid-Hansen
Anders Hvid-Hansen
NJNina Jacobsen
Nina Jacobsen
JHJesper Hjortdal
Jesper Hjortdal
FMFlemming Møller
Flemming Møller
BOBrice Ozenne
Brice Ozenne
LKLine Kessel
Line Kessel
This study aimed to investigate changes in non-cycloplegic ocular biometrics during the initial six months of treatment with a 0.1% atropine loading dose and 0.01% atropine compared with a placebo and analyze their contribution to the treatment effect on cycloplegic spherical equivalent (SE) progression. The study was based on a randomized, double-masked, placebo-controlled, multicenter trial evaluating a 0.1% atropine six-month loading dose and 0.01% atropine in reducing myopic progression in Danish children. The treatment phase was 24 months, and the washout phase was 12 months. Parameters measured included changes in axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and choroidal thickness (ChT), while cycloplegic SE and lens power were calculated. Longitudinal changes and contributions to treatment effects were analyzed using constrained linear mixed models and mediation analyses, respectively. After six months, AL was 0.13 mm shorter (95% confidence interval [CI], −0.18 to −0.07 [adjusted p < 0.001]) and 0.06 mm shorter (95% CI, −0.11 to −0.01 [adjusted p = 0.060]) with a 0.1% atropine loading dose and 0.01% atropine, respectively, compared to the placebo group. Similar concentration-dependent changes were found with ACD, LT, VCD, ChT, and cycloplegic SE. Although the treatment effects trended toward concentration-dependent responses, only the treatment effect mediated by AL at three months differed significantly between 0.01% atropine and a 0.1% atropine loading dose (adjusted p = 0.023). Several ocular biometrics, including AL, ACD, and LT, changed dose-dependently during low-dose atropine treatment. Moreover, the treatment effect of atropine on SE progression was mediated by a subset of ocular biometrics, mainly AL, with trends toward concentration dependency and distributional shifts over time.

15 June 2022 in American Journal of Transplantation
Verified
Journal Article
Open access
JHJesper Hjortdal
Jesper Hjortdal
Matthew GriffinMatthew Griffin
Matthew Griffin
MCMarion Cadoux
Marion Cadoux
WAW. John Armitage
W. John Armitage
MBMax Bylesjo
Max Bylesjo
Nicolas DegauqueNicolas Degauque
Nicolas Degauque
Acute rejection (AR) of corneal transplants (CT) has a profound effect on subsequent graft survival but detailed immunological studies in human CT recipients are lacking. In this multi‐site, cross‐sectional study, clinical details and blood samples were collected from adults with clinically diagnosed AR of full‐thickness (FT)‐CT (n = 35) and posterior lamellar (PL)‐CT (n = 21) along with Stable CT recipients (n = 177) and adults with non‐transplanted corneal disease (n = 40). For those with AR, additional samples were collected 3 months later. Immune cell analysis was performed by whole‐genome microarrays (whole blood) and high‐dimensional multi‐color flow cytometry (peripheral blood mononuclear cells). For both, no activation signature was identified within the B cell and T cell repertoire at the time of AR diagnosis. Nonetheless, in FT‐ but not PL‐CT recipients, AR was associated with differences in B cell maturity and regulatory CD4+ T cell frequency compared to stable allografts. These data suggest that circulating B cell and T cell subpopulations may provide insights into the regulation of anti‐donor immune response in human CT recipients with differing AR risk. Our results suggest that, in contrast to solid organ transplants, genetic or cellular assays of peripheral blood are unlikely to be clinically exploitable for prediction or diagnosis of AR.

Verified
Journal Article
Open access
PDF file
SASara Aghazadeh
Sara Aghazadeh
QPQiuyue Peng
Qiuyue Peng
FDFereshteh Dardmeh
Fereshteh Dardmeh
JHJesper Hjortdal
Jesper Hjortdal
VZVladimir Zachar
Vladimir Zachar
Hiva AlipourHiva Alipour
Hiva Alipour
Limbal mesenchymal stromal cells (LMSCs) reside in the limbal niche, supporting corneal integrity and facilitating regeneration. While mesenchymal stem/stromal cells (MSCs) are used in regenerative therapies, there is limited knowledge about LMSC subpopulations and their characteristics. This study characterized human LMSC subpopulations through the flow cytometric assessment of fifteen cell surface markers, including MSC, wound healing, immune regulation, ASC, endothelial, and differentiation markers. Primary LMSCs were established from remnant human corneal transplant specimens and passaged eight times to observe changes during subculture. The results showed the consistent expression of typical MSC markers and distinct subpopulations with the passage-dependent expression of wound healing, immune regulation, and differentiation markers. High CD166 and CD248 expressions indicated a crucial role in ocular surface repair. CD29 expression suggested an immunoregulatory role. Comparable pigment-epithelial-derived factor (PEDF) expression supported anti-inflammatory and anti-angiogenic roles. Sustained CD201 expression indicated maintained differentiation capability, while VEGFR2 expression suggested potential endothelial differentiation. LMSCs showed higher VEGF expression than fibroblasts and endothelial cells, suggesting a potential contribution to ocular surface regeneration through the modulation of angiogenesis and inflammation. These findings highlight the heterogeneity and multipotent potential of LMSC subpopulations during in vitro expansion, informing the development of standardized protocols for regenerative therapies and improving treatments for ocular surface disorders.

6 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
MJMarina José-Martínez
Marina José-Martínez
AAAntonio Martinez Abad
Antonio Martinez Abad
ARAlejandra Rodriguez
Alejandra Rodriguez
FVFrancesco Versaci
Francesco Versaci
David P PiñeroDavid P Piñero
David P Piñero
The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: −0.04 to 0.03 mm) and CCT (LoA: −4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

Verified
Journal Article
Open access
PDF file
AHAnders Hvid-Hansen
Anders Hvid-Hansen
Per BækgaardPer Bækgaard
Per Bækgaard
NJNina Jacobsen
Nina Jacobsen
JHJesper Hjortdal
Jesper Hjortdal
FMFlemming Møller
Flemming Møller
LKLine Kessel
Line Kessel
This study aimed to investigate the reproducibility of pupil size measurements over time and between reading methods when comparing human-assisted reading to automated reading. Pupillary data were analyzed on a subset of myopic children enrolled in a multicenter randomized clinical trial on myopia control with low-dose atropine. Pupil size measurements were obtained prior to randomization at two time points (screening and baseline visits) using a dedicated pupillometer under mesopic and photopic conditions. A customized algorithm was built to perform automated readings, allowing comparisons between human-assisted and automated readings. Reproducibility analyses followed the principles of Bland and Altman and included the calculation of the mean difference between measurements and limits of agreement (LOA). We included 43 children. Mean (standard deviation) age was 9.8 (1.7) years and 25 (58%) children were girls. Using human-assisted readings, reproducibility over time showed mesopic mean difference of 0.02 mm with LOA from −0.87 mm to 0.91 mm, whereas photopic mean difference was −0.01 mm with LOA from −0.25 mm to 0.23 mm. Reproducibility between human-assisted and automated readings was also higher under photopic conditions, with mean difference of 0.03 mm and LOA from −0.03 mm to 0.10 mm at screening and mean difference of 0.03 mm and LOA from −0.06 mm to 0.12 mm at baseline. Using a dedicated pupillometer, we found that examinations performed under photopic conditions demonstrated higher reproducibility over time and between reading methods. We speculate whether mesopic measurements are sufficiently reproducible to be monitored over time. Furthermore, photopic measurements may be of greater relevance when evaluating the side effects of atropine treatment, such as photophobia.

21 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
MJMarina José-Martínez
Marina José-Martínez
AAAntonio Martinez Abad
Antonio Martinez Abad
ARAlejandra Rodriguez
Alejandra Rodriguez
FVFrancesco Versaci
Francesco Versaci
David P PiñeroDavid P Piñero
David P Piñero
The VEMoS AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is considered the gold standard, for an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system and afterwards a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, re-spectively. The agreement between devices was good for AL (Limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.