Hans Lemij

Dr. Hans Lemij


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in Ophthalmology
Verified
Journal Article
Closed access
NPNorbert Pfeiffer
Norbert Pfeiffer
JGJulián García-Feijóo
Julián García-Feijóo
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
JLJose M. Larrosa
Jose M. Larrosa
AFAntonio Fea
Antonio Fea
TSThomas W. Samuelson
Thomas W. Samuelson

15 September 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
CVCoen de Vente
Coen de Vente
KVKoenraad A. Vermeer
Koenraad A. Vermeer
NJNicolas Jaccard
Nicolas Jaccard
HWHe Wang
He Wang
HSHongyi Sun
Hongyi Sun
CSClara I. Sánchez
Clara I. Sánchez
The early detection of glaucoma is essential in preventing visual impairment. Artificial intelligence (AI) can be used to analyze color fundus photographs (CFPs) in a cost-effective manner, making glaucoma screening more accessible. While AI models for glaucoma screening from CFPs have shown promising results in laboratory settings, their performance decreases significantly in real-world scenarios due to the presence of out-of-distribution and low-quality images. To address this issue, we propose the Artificial Intelligence for Robust Glaucoma Screening (AIROGS) challenge. This challenge includes a large dataset of around 113,000 images from about 60,000 patients and 500 different screening centers, and encourages the development of algorithms that are robust to ungradable and unexpected input data. We evaluated solutions from 14 teams in this paper and found that the best teams performed similarly to a set of 20 expert ophthalmologists and optometrists. The highest-scoring team achieved an area under the receiver operating characteristic curve of 0.99 (95% CI: 0.98-0.99) for detecting ungradable images on-the-fly. Additionally, many of the algorithms showed robust performance when tested on three other publicly available datasets. These results demonstrate the feasibility of robust AI-enabled glaucoma screening.

30 January 2019 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
JVJuan P. Vigueras-Guillén
Juan P. Vigueras-Guillén
BSBusra Sari
Busra Sari
SGStanley F. Goes
Stanley F. Goes
HLHans Lemij
Hans Lemij
JRJeroen van Rooij
Jeroen van Rooij
LVLucas J. van Vliet
Lucas J. van Vliet
Corneal endothelium (CE) images provide valuable clinical information regarding the health state of the cornea. Computation of the clinical morphometric parameters requires the segmentation of endothelial cell images. Current techniques to image the endothelium in vivo deliver low quality images, which makes automatic segmentation a complicated task. Here, we present two convolutional neural networks (CNN) to segment CE images: a global fully convolutional approach based on U-net, and a local sliding-window network (SW-net). We propose to use probabilistic labels instead of binary, we evaluate a preprocessing method to enhance the contrast of images, and we introduce a postprocessing method based on Fourier analysis and watershed to convert the CNN output images into the final cell segmentation. Both methods are applied to 50 images acquired with an SP-1P Topcon specular microscope. Estimates are compared against a manual delineation made by a trained observer. U-net (AUC=0.9938) yields slightly sharper, clearer images than SW-net (AUC=0.9921). After postprocessing, U-net obtains a DICE=0.981 and a MHD=0.22 (modified Hausdorff distance), whereas SW-net yields a DICE=0.978 and a MHD=0.30. U-net generates a wrong cell segmentation in only 0.48% of the cells, versus 0.92% for the SW-net. U-net achieves statistically significant better precision and accuracy than both, Topcon and SW-net, for the estimates of three clinical parameters: cell density (ECD), polymegethism (CV), and pleomorphism (HEX). The mean relative error in U-net for the parameters is 0.4% in ECD, 2.8% in CV, and 1.3% in HEX. The computation time to segment an image and estimate the parameters is barely a few seconds. Both methods presented here provide a statistically significant improvement over the state of the art. U-net has reached the smallest error rate. We suggest a segmentation refinement based on our previous work to further improve the performance.

17 March 2023 in Ophthalmology Science
Verified
Journal Article
Open access
HLHans Lemij
Hans Lemij
CVCoen de Vente
Coen de Vente
CSClara I. Sánchez
Clara I. Sánchez
KVKoen A. Vermeer
Koen A. Vermeer
Significant visual impairment due to glaucoma is largely caused by the disease being detected too late. To build a labeled data set for training artificial intelligence (AI) algorithms for glaucoma screening by fundus photography, to assess the accuracy of the graders, and to characterize the features of all eyes with referable glaucoma (RG). Cross-sectional study. Color fundus photographs (CFPs) of 113 893 eyes of 60 357 individuals were obtained from EyePACS, California, United States, from a population screening program for diabetic retinopathy. Carefully selected graders (ophthalmologists and optometrists) graded the images. To qualify, they had to pass the European Optic Disc Assessment Trial optic disc assessment with ≥ 85% accuracy and 92% specificity. Of 90 candidates, 30 passed. Each image of the EyePACS set was then scored by varying random pairs of graders as “RG,” “no referable glaucoma (NRG),” or "ungradable (UG).” In case of disagreement, a glaucoma specialist made the final grading. Referable glaucoma was scored if visual field damage was expected. In case of RG, graders were instructed to mark up to 10 relevant glaucomatous features. Qualitative features in eyes with RG. The performance of each grader was monitored; if the sensitivity and specificity dropped below 80% and 95%, respectively (the final grade served as reference), they exited the study and their gradings were redone by other graders. In all, 20 graders qualified; their mean sensitivity and specificity (standard deviation [SD]) were 85.6% (5.7) and 96.1% (2.8), respectively. The 2 graders agreed in 92.45% of the images (Gwet’s AC2, expressing the inter-rater reliability, was 0.917). Of all gradings, the sensitivity and specificity (95% confidence interval) were 86.0 (85.2–86.7)% and 96.4 (96.3–96.5)%, respectively. Of all gradable eyes (n = 111 183; 97.62%) the prevalence of RG was 4.38%. The most common features of RG were the appearance of the neuroretinal rim (NRR) inferiorly and superiorly. A large data set of CFPs was put together of sufficient quality to develop AI screening solutions for glaucoma. The most common features of RG were the appearance of the NRR inferiorly and superiorly. Disc hemorrhages were a rare feature of RG. Proprietary or commercial disclosure may be found after the references.

29 May 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
JVJuan P. Vigueras-Guillen
Juan P. Vigueras-Guillen
EAEleni-Rosalina Andrinopoulou
Eleni-Rosalina Andrinopoulou
AEAngela Engel
Angela Engel
HLHans Lemij
Hans Lemij
JRJeroen van Rooij
Jeroen van Rooij
LVLucas J. van Vliet
Lucas J. van Vliet
Corneal endothelium images obtained by in vivo specular microscopy provide important information to assess the health status of the cornea. Estimation of clinical parameters, such as cell density, polymegethism, and pleomorphism, requires accurate cell segmentation. State-of-the-art techniques to automatically segment the endothelium are error-prone when applied to images with low contrast and/or large variation in cell size. Here, we propose an automatic method to segment the endothelium. Starting with an oversegmented image comprised of superpixels obtained from a stochastic watershed segmentation, the proposed method uses intensity and shape information of the superpixels to identify and merge those that constitute a cell, using Support Vector Machines. We evaluated the automatic segmentation on a dataset of in vivo specular microscopy images (Topcon SP-1P), obtaining 95.8merged cells and 2.0the parameter estimation against the results of the vendor’s builtin software, obtaining a statistically significant better precision in all parameters and a similar or better accuracy. The parameter estimation was also evaluated on three other datasets from different imaging modalities (confocal microscopy, phasecontrast microscopy, and fluorescence confocal microscopy) and tissue types (ex vivo corneal endothelium and retinal pigment epithelium). In comparison with the estimates of the datasets’ authors, we achieved statistically significant better accuracy and precision in all parameters except pleomorphism, where a similar accuracy and precision were obtained.

7 November 2010 in Journal of Medical Genetics
Verified
Journal Article
Open access
PDF file
WRWishal Ramdas
Wishal Ramdas
NANajaf Amin
Najaf Amin
LKLeonieke M E van Koolwijk
Leonieke M E van Koolwijk
AJA. Cecile J.w. Janssens
A. Cecile J.w. Janssens
Ayse DemirkanAyse Demirkan
Ayse Demirkan
Cornelia Van DuijnCornelia Van Duijn
Cornelia Van Duijn
Background Although the vertical cup-disc ratio (VCDR) and intraocular pressure (IOP) are important determinants of open angle glaucoma (OAG), it is unclear to what extent the genetic origin of these traits overlap with those of OAG. We evaluated whether the same genes that determine VCDR and IOP also predict OAG. Methods Genetic risk scores were constructed from single nucleotide polymorphisms (SNPs) using genome wide association data of 9326 participants from the Rotterdam Study cohorts (mean±SD age: 64.6±9.1 years). These risk scores were used to calculate the explained variance of VCDR and IOP in an independent cohort (Erasmus Rucphen Family study) consisting of 1646 participants (mean±SD age: 46.8±14.1 years) and the OAG risk in a subset of the Rotterdam Study cohorts. To evaluate false positive findings, we generated two new variables containing randomly sampled values to serve as a negative control. Results The explained variance of VCDR increased when increasing the number of SNPs included in the risk score, suggesting a polygenic model. We found no clear evidence for a similar model for IOP, suggesting that a small number of SNPs determine the susceptibility to IOP. The SNPs related to IOP in terms of p values contributed little to VCDR. The risk scores associated with VCDR were also associated significantly with OAG. This suggests a common polygenic background for VCDR and OAG Conclusions We found evidence for a polygenic model underlying one of the major traits of OAG, VCDR, and OAG itself. The IOP did not show any evidence for such a model.