Umar S Boston

Dr. Umar S Boston

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
JMJacob R. Miller
Jacob R. Miller
KSKathleen E. Simpson
Kathleen E. Simpson
DEDeirdre J. Epstein
Deirdre J. Epstein
TLTimothy S. Lancaster
Timothy S. Lancaster
MHMatthew C. Henn
Matthew C. Henn
UBUmar S Boston
Umar S Boston

1 May 2011 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
UBUmar S Boston
Umar S Boston
SGSteven P. Goldberg
Steven P. Goldberg
KWKent E. Ward
Kent E. Ward
EOEdward D. Overholt
Edward D. Overholt
TSThomas Spentzas
Thomas Spentzas
CKChristopher J. Knott-Craig
Christopher J. Knott-Craig

29 June 2016 in World Journal for Pediatric and Congenital Heart Surgery
Verified
Journal Article
Open access
PDF file
JMJacob R Miller
Jacob R Miller
MHMatthew C Henn
Matthew C Henn
TLTimothy S. Lancaster
Timothy S. Lancaster
CLChristopher P. Lawrance
Christopher P. Lawrance
RSRichard B. Schuessler
Richard B. Schuessler
UBUmar S Boston
Umar S Boston
Prosthetic materials available for pediatric pulmonary valve replacement (PVR) lack growth potential, inevitably leading to a size mismatch. Small intestine submucosa–derived extracellular matrix (SIS-ECM) has been suggested to possess regenerative properties. We aimed to investigate its function and potential to increase in size as a PVR in a piglet. An SIS-ECM trileaflet valved conduit was designed. Hanford minipigs, n = 6 (10-34 kg), underwent PVR with an intended survival of six months, with monthly echocardiograms evaluating valve size and function. The conduit was excised for histologic analysis. Of the six, one was sacrificed at three months for midterm analysis, and one at month 3 due to endocarditis. The remaining four constituted the study cohort. The piglet weight increased by 186% (19.56 ± 10.22 kg to 56.00 ± 7.87 kg). Conduit size increased by 30% (1.42 ± 0.14 cm to 1.84 ± 0.14 cm; P < .01). The native right ventricular outflow tract increased by 43% and the native pulmonary artery by 84%, resulting in a peak gradient increase from 10.08 ± 2.47 mm Hg to 36.25 ± 18.80 mm Hg (P = .03). Additionally, all valves developed at least moderate regurgitation. Conduit histology showed advanced remodeling with myofibroblast infiltration, neovascularization, and endothelialization. The leaflets remodeled beginning at the base with the leaflet edge being less cellular. In addition to the known endocarditis, bacterial colonies were discovered within a leaflet in another. The SIS-ECM valved conduit implanted into a piglet demonstrated cellular infiltration with vascular remodeling and an increase in diameter. Conduit stenosis was a result of slower rates of size increase than native tissue. Suboptimal leaflet performance requires design modifications.

31 May 2010 in The Journal of Pediatrics
Verified
Journal Article
Closed access
SGSteven P. Goldberg
Steven P. Goldberg
UBUmar S Boston
Umar S Boston
DTDima A. Turpin
Dima A. Turpin
GMGiancarlo C. Mari
Giancarlo C. Mari
CMCraig A. Mathis
Craig A. Mathis
CKChristopher J. Knott-Craig
Christopher J. Knott-Craig

1 July 2017 in ASAIO Journal
Verified
Journal Article
Closed access
JMJacob R. Miller
Jacob R. Miller
TLTimothy S. Lancaster
Timothy S. Lancaster
DEDeirdre J. Epstein
Deirdre J. Epstein
NDNicholas C. DuPont
Nicholas C. DuPont
KSKathleen E. Simpson
Kathleen E. Simpson
UBUmar S Boston
Umar S Boston
We aimed to examine trends in ventricular assist device (VAD) selection, continuous flow devices (CFD) versus pulsatile flow devices (PFD), and their associated outcomes in children eligible for both device types. To accomplish this, the United Network for Organ Sharing database was reviewed for pediatric patients listed for heart transplant (HT) from January 2007 to June 2014. Patients were included if a durable VAD was present at wait listing or when removed from the waiting list and who met size eligibility for a CFD (BSA > 1.0 m2). In total, 253 patients met inclusion criteria, 144 (57%) CFD and 109 (43%) PFD. Device type varied significantly based on year with CFD increasing from 11% in 2007 to 88% in 2014 (p < 0.01). PFD patients were younger, had a lower BSA, and an increased rate of extracorporeal membrane oxygenation and biventricular assist device support at listing. Survival to transplant or recovery was similar for CFDs and PFDs (96 vs. 94%; p = 0.57), as was the post-HT survival, 95% for both device types. Despite PFD patients having more risk factors for a poor outcome, survival was similar between device types. Even so, there is a dramatic trend toward CFD utilization in patients who are large enough to support one.

20 January 2023 in JTCVS Techniques
Verified
Journal Article
Open access
EHEvan Harvey
Evan Harvey
MAMohammed Absi
Mohammed Absi
NTNeil Tailor
Neil Tailor
CKChristopher J. Knott-Craig
Christopher J. Knott-Craig
UBUmar S Boston
Umar S Boston