The capacity of an energy storage device configuration not only affects the economic operation of a microgrid, but also affects the power supply’s reliability. An isolated microgrid is considered with typical loads, renewable energy resources, and a hybrid energy storage system (HESS) composed of batteries and ultracapacitors in this paper. A quantum-behaved particle swarm optimization (QPSO) algorithm that optimizes the HESS capacity is used. Based on the respective power compensation capabilities of ultracapacitors and batteries, a rational energy scheduling strategy is proposed using the principle of a low-pass filter and can help to avoid frequent batteries charging and discharging. Considering the rated power of each energy storage type, the respective compensation power is corrected. By determining whether the charging state reaches the limit, the value is corrected again. Additionally, a mathematical model that minimizes the daily cost of the HESS is derived. This paper takes an isolated micrgrid in north China as an example to verify the effectiveness of this method. The comparison between QPSO and a traditional particle swarm algorithm shows that QPSO can find the optimal solution faster and the HESS has lower daily cost. Simulation results for an isolated microgrid verified the effectiveness of the HESS optimal capacity configuration method.
Due to the randomness and volatility of solar power generation, energy storage system (ESS) with its peak shaving and valley filling ability is widely used in electrical power system (EPS). This paper proposes a coordinated operation model of power system and energy storage with solar generation. The proposed model minimizes system operation cost when considering high penetration of solar generation. Case studies illustrate effectiveness of the proposed model especially the ESS operation for reduce solar spillage in high penetration and assure the security of power system.
The existing low-frequency oscillation analysis method of a multi-grid-forming-VSC (voltage source converter) is greatly affected by modeling accuracy, and its oscillation mode can only be determined by acquiring the control parameters of the system. Therefore, a method of identifying low-frequency oscillation characteristics of multi-VSC based on VMD (variational mode decomposition) and a Prony algorithm was proposed in this paper. The Prony algorithm is sensitive to noise, and its identification accuracy is greatly affected by noise. Thus, the VMD algorithm was utilized to denoise the measured data. Then, the Prony algorithm was applied to analyze the low-frequency oscillation of the measured data of single VSC and multi-VSC grid-connected systems, and its applicability to different grid-forming VSCs was verified. The error comparison results showed that the proposed low-frequency oscillation identification method had high accuracy. Furthermore, the influence of the number of parallel VSCs, grid strength and active output on the low-frequency oscillation of the system was investigated. Finally, the effectiveness of the proposed low-frequency oscillation method was verified by building a physical experimental platform.