The harmonic and resonant characteristics of a multi-inverter grid-connected system can negatively affect power quality when weak grid conditions are present. In this paper, firstly, harmonic currents are modeled for the inverter, the correctness of low-frequency harmonics and high-frequency harmonics are verified in closed loop, and the characteristics of harmonic currents are analyzed when the parameters are varied. Secondly, the resonant characteristics of the inverter with feed-forward link are analyzed, and a multi-inverter grid-connected equivalent model based on the triple-decomposition conductance is developed and analyzed in conjunction with the resonant modal analysis method. Then, a harmonic resonance impedance reshaping method is proposed to suppress the background harmonics using improved weighted average current control (WACC), suppress the system resonance based on the point of common coupling (PCC) paralleling virtual conductance method, and improve the stability margin of the system combined with impedance reshaping resonance suppression method. Finally, simulations and comparison of results with different suppression methods verify the superiority and effectiveness of the proposed method.
The existing low-frequency oscillation analysis method of a multi-grid-forming-VSC (voltage source converter) is greatly affected by modeling accuracy, and its oscillation mode can only be determined by acquiring the control parameters of the system. Therefore, a method of identifying low-frequency oscillation characteristics of multi-VSC based on VMD (variational mode decomposition) and a Prony algorithm was proposed in this paper. The Prony algorithm is sensitive to noise, and its identification accuracy is greatly affected by noise. Thus, the VMD algorithm was utilized to denoise the measured data. Then, the Prony algorithm was applied to analyze the low-frequency oscillation of the measured data of single VSC and multi-VSC grid-connected systems, and its applicability to different grid-forming VSCs was verified. The error comparison results showed that the proposed low-frequency oscillation identification method had high accuracy. Furthermore, the influence of the number of parallel VSCs, grid strength and active output on the low-frequency oscillation of the system was investigated. Finally, the effectiveness of the proposed low-frequency oscillation method was verified by building a physical experimental platform.
Addressing the problem that energy supply and load demand cannot be matched due to the difference in inertia effects among multiple energy sources, and taking into account the thermoelectric load, this paper designs a two-stage operation optimization model of IES considering multi-dimensional thermal inertia and constructs an intelligent adaptive solution method based on a time scale-model base. Validation is conducted through an arithmetic example. Scenario 2 has 15.3% fewer CO2 emissions than Scenario 1, 19.7% less purchased electricity, and 20.0% less purchased electricity cost. The optimal algorithm for the day-ahead phase is GA, and the optimal algorithm for the intraday phase is PSO, which is able to produce optimization results in a few minutes.
In order to improve the trading efficiency of virtual power plants (VPPs) participating in the market of multi-type auxiliary services under the gaming environment, an initial trading price setting method based on the information of VPPs’ response characteristics and real-time supply and demand changes is proposed to accelerate the convergence speed of the game. Firstly, a master–slave game trading model is established based on the reference auxiliary service pricing, which consists of a tariff coefficient and a basic tariff. Secondly, the tariff coefficient model is constructed based on response information, including response rate, quality, and reliability. Again, the basic tariff model is constructed based on the real-time supply and demand situation and the real-time grid tariff. Finally, the effectiveness of the proposed method in accelerating the convergence speed of the game is verified by analyzing 12 VPPs under the three auxiliary service scenarios of peaking, frequency regulation, and reserve.
With the integration of high-penetration distributed renewable energy sources and grid-forming inverters, AC microgrids face significant challenges in maintaining autonomous voltage and frequency stability. While traditional droop control can achieve autonomous power allocation, it introduces inherent steady-state deviations when load change. To address this, this paper proposes a distributed secondary control strategy for AC microgrids based on a consensus algorithm, aiming to achieve high-precision coordinated correction of voltage and frequency and improve power quality. In the proposed strategy, each grid-forming inverter autonomously generates dynamic secondary compensation signals based solely on local measurements and limited information exchange with neighboring nodes, eliminating the need for a central controller and enhancing robustness, scalability, and fault tolerance. Stability is proven via Lyapunov function construction. Simulation results show that the strategy effectively eliminates steady-state errors, with frequency deviations within ±0.01 Hz and voltage deviations below 0.5% of the rated value. Rapid and precise regulation is achieved under various load disturbances and network conditions, validating its effectiveness and application potential.
To address the deep spatiotemporal coupling of source-load dual uncertainties attributed to the high penetration of distributed photovoltaics (PVs) and electric vehicles (EVs) into distribution grids, and the difficulty of analyzing composite disturbances using traditional methods, this paper proposes a voltage quality analysis method that considers spatiotemporal coupling of source-load uncertainty, focusing on steady-state voltage deviation and three-phase imbalance problems. First, a probabilistic model of PV generation is constructed using the beta distribution combined with Monte Carlo-based scenario reduction, and high-precision forecasting of EV charging loads is achieved by an attention-based convolutional neural network and long short-term memory network. Second, multi-scenario spatiotemporal power flow calculations are conducted on the distribution network to analyze the complementary effects of voltage deviation and three-phase imbalance under the hybrid integration of PV and EV. Finally, gray wolf optimization-based variational mode decomposition is introduced to adaptively decompose the source-load power. This reveals the intrinsic mechanisms where low-frequency components dominate the fundamental amplitude variations of bus voltages, while high-frequency components exert a significant impact on voltage quality. Simulation results demonstrate that the proposed method can effectively analyze the spatiotemporal coupling of source-load uncertainties, providing technical support for the comprehensive management of voltage quality in distribution networks.