Miguel  Fernando Moctezuma Sanchez

Dr. Miguel Fernando Moctezuma Sanchez


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2008 in Microgravity Science and Technology
Verified
Journal Article
Closed access
PDF file
MSMiguel Fernando Moctezuma Sanchez
Miguel Fernando Moctezuma Sanchez
LDLuis A. Dávalos-Orozco
Luis A. Dávalos-Orozco

26 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
MSMiguel Fernando Moctezuma Sanchez
Miguel Fernando Moctezuma Sanchez
DGDavid Espinoza Gómez
David Espinoza Gómez
Luis Bernardo López-SosaLuis Bernardo López-Sosa
Luis Bernardo López-Sosa
IGIman Golpour
Iman Golpour
Mario Morales-MáximoMario Morales-Máximo
Mario Morales-Máximo
RGRicardo González-Carabes
Ricardo González-Carabes
Estimating energy flows that affect temperature increases inside houses is crucial for optimizing building design and enhancing the comfort of living spaces. In this study, a thermal model has been developed to estimate the internal temperature of rural houses in Mexico using aerial thermography. The methodology used in this study considered three stages: (a) generating a semi-experimental thermal model of heat transfer through roofs for houses with high infiltration, (b) validating the model using contact thermometers in rural community houses, and (c) integrating the developed model using aerial thermography and Python 3.11.4 into user-friendly software. The results demonstrate that the thermal model is effective, as it was tested on two rural house configurations and achieved an error margin of less than 10% when predicting both maximum and minimum temperatures compared to actual measurements. The model consistently estimates the internal house temperatures using aerial thermography by measuring the roof temperatures. Experimental comparisons of internal temperatures in houses with concrete and asbestos roofs and the model’s projections showed deviations of less than 3 °C. The developed software for this purpose relies solely on the fundamental thermal properties of the roofing materials, along with the maximum roof temperature and ambient temperature, making it both efficient and user-friendly for rural community management systems. Additionally, the model identified areas with comfortable temperatures within different sections of a rural community, demonstrating its effectiveness when integrated with aerial thermography. These findings suggest the potential to estimate comfortable temperature ranges in both rural and urban dwellings, while also encouraging the development of public policies aimed at improving rural housing.