Iman Golpour

Dr. Iman Golpour

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
José Daniel MarcosJosé Daniel Marcos
José Daniel Marcos
IGIman Golpour
Iman Golpour
RBRuben Barbero
Ruben Barbero
ARAntonio Rovira
Antonio Rovira
This study examines the potential for the smart integration of waste and renewable energy sources to supply industrial heat at temperatures between 150 °C and 250 °C, aiming to decarbonize heat demand in European industry. This work is part of a European project (SUSHEAT) which focuses on developing a novel technology that integrates several innovative components: a Stirling cycle high-temperature heat pump (HTHP), a bio-inspired phase change material (PCM) thermal energy storage (TES) system, and a control and integration twin (CIT) system based on smart decision-making algorithms. The objective is to develop highly efficient industrial heat upgrading systems for industrial applications using renewable energy sources and waste heat recovery. To achieve this, the specific heat requirements of different European industries were analyzed. The findings indicate that industrial sectors such as food and beverages, plastics, desalination, textiles, ceramics, pulp and paper, wood products, canned food, agricultural products, mining, and chemicals, typically require process heat at temperatures below 250 °C under conditions well within the range of the SUSHEAT system. Moreover, two case studies, namely the Pelagia and Mandrekas companies, were conducted to validate the effectiveness of the system. An analysis of the annual European heat demand by sector and temperature demonstrated that the theoretical potential heat demand that could be met by the SUSHEAT system is 134.92 TWh annually. Furthermore, an environmental impact assessment estimated an annual significant reduction of 19.40 million tonnes of CO2 emissions. These findings underscore the significant potential of the SUSHEAT system to contribute to the decarbonization of European industry by efficiently meeting heat demand and substantially reducing carbon emissions.

21 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KSKazem Sasani
Kazem Sasani
Yousef Abbaspour-GilandehYousef Abbaspour-Gilandeh
Yousef Abbaspour-Gilandeh
Mohammad KavehMohammad Kaveh
Mohammad Kaveh
IGIman Golpour
Iman Golpour
José Daniel MarcosJosé Daniel Marcos
José Daniel Marcos
Dill is a valuable herb recognized for its rich nutritional composition and bioactive properties. Drying is an efficient preservation technique for maintaining its quality characteristics and ensuring longer storage stability. Incorporating ultrasonic pretreatment before the drying process can significantly reduce energy consumption (SEC) and greenhouse gas emissions. To the best of our knowledge, this is the first study to comprehensively evaluate ultrasound-assisted hybrid microwave–convective drying of dill (Anethum graveolens L.) leaves, focusing on the combined effects on drying kinetics, energetic and exergetic performance, providing an indirect emission estimate and multiple quality attributes. This study aimed to evaluate the drying kinetics, energy and exergy performance parameters, greenhouse gas emissions, quality properties (water activity, rehydration ratio and color) and antioxidant capacity of dill leaves dried by the microwave–hot-air (MW-HA) technique combined with ultrasonic (US) pretreatment. The experiments were conducted at MW power levels of 20%, 40%, and 60% (corresponding to a total output of 900 W), air temperatures of 40 and 60 °C, and US pretreatment durations of 0, 10, and 30 min. The results illustrated that rising MW power, air temperature and US duration significantly reduced the drying time, SEC and greenhouse gas emissions. At higher process conditions, specifically, 40% MW power, 60 °C drying temperature, and 30 min US pretreatment, the maximum energy efficiency (10.17%) and exergy efficiency (11.35%) were obtained. In terms of quality attributes, the best results were achieved at 40% MW power, 60 °C air temperature, and 10 min ultrasonic pretreatment, with reduced water activity (0.258), minimal color variation (ΔE = 11.44), improved rehydration ratio (3.88), and high retention of antioxidant activity. These findings demonstrate the potential of ultrasound pretreatment to enhance drying performance by reducing energy use and emissions while improving quality and antioxidant retention in dill, offering new guidelines for sustainable processing of this herb. Future studies should optimize microwave–hot-air-drying conditions to balance energy efficiency, exergy, and product quality.

26 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
MSMiguel Fernando Moctezuma Sanchez
Miguel Fernando Moctezuma Sanchez
DGDavid Espinoza Gómez
David Espinoza Gómez
Luis Bernardo López-SosaLuis Bernardo López-Sosa
Luis Bernardo López-Sosa
IGIman Golpour
Iman Golpour
Mario Morales-MáximoMario Morales-Máximo
Mario Morales-Máximo
RGRicardo González-Carabes
Ricardo González-Carabes
Estimating energy flows that affect temperature increases inside houses is crucial for optimizing building design and enhancing the comfort of living spaces. In this study, a thermal model has been developed to estimate the internal temperature of rural houses in Mexico using aerial thermography. The methodology used in this study considered three stages: (a) generating a semi-experimental thermal model of heat transfer through roofs for houses with high infiltration, (b) validating the model using contact thermometers in rural community houses, and (c) integrating the developed model using aerial thermography and Python 3.11.4 into user-friendly software. The results demonstrate that the thermal model is effective, as it was tested on two rural house configurations and achieved an error margin of less than 10% when predicting both maximum and minimum temperatures compared to actual measurements. The model consistently estimates the internal house temperatures using aerial thermography by measuring the roof temperatures. Experimental comparisons of internal temperatures in houses with concrete and asbestos roofs and the model’s projections showed deviations of less than 3 °C. The developed software for this purpose relies solely on the fundamental thermal properties of the roofing materials, along with the maximum roof temperature and ambient temperature, making it both efficient and user-friendly for rural community management systems. Additionally, the model identified areas with comfortable temperatures within different sections of a rural community, demonstrating its effectiveness when integrated with aerial thermography. These findings suggest the potential to estimate comfortable temperature ranges in both rural and urban dwellings, while also encouraging the development of public policies aimed at improving rural housing.

21 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
CSCarlos Sánchez-Ixta
Carlos Sánchez-Ixta
JVJuan Rodrigo Vázquez-Abarca
Juan Rodrigo Vázquez-Abarca
Luis Bernardo López-SosaLuis Bernardo López-Sosa
Luis Bernardo López-Sosa
IGIman Golpour
Iman Golpour
The studies on strategies for improving restoration times in electrical distribution systems are extensive. They have theoretically explored the application of mathematical models, the implementation of remotely controlled systems, and the use of digital simulators. This research aims to connect conceptual studies and the implementation of improvements and impact assessment in electrical distribution systems in developing countries, where distribution technologies vary widely, by employing a comprehensive methodology. The proposed research examines the restoration times for faults in substations within general distribution networks in the central–western region of Mexico. The study comprises these stages: (a) diagnosing the electrical supply, demand, and infrastructure; (b) analyzing the electrical restoration time and the restoration index of the substations; and (c) providing recommendations and implementing pilot tests for improvements in the identified critical substations. The results revealed 12 analysis zones, including 120 distribution substations, 150 power transformers, and 751 medium voltage circuits. Among the substations, 73% have ring connections, 15% have TAP connections, and 12% have radial connections. Additionally, 27% of the substations rely on only a single distribution line. The study identified areas with significant challenges in restoring electricity supply, particularly focusing on power transformers: 32 transformers with permanent power line failures requiring load transfer via medium voltage; 67 transformers requiring optimized restoration maneuvers due to specific characteristics; and 4 areas with opportunities to enhance the reliability of the power supply through remote-controlled link systems. The analysis resulted in the installation of 145 remote link systems, which improved restoration rates by over 40%. This approach is expected to be replicated throughout Mexico to identify improvements needed in the national distribution system.

30 January 2026 in Energy and Buildings
Verified
Journal Article
Open access
IGIman Golpour
Iman Golpour
JMJosé Daniel Marcos
José Daniel Marcos
RBRubén Barbero
Rubén Barbero
ARAntonio Rovira
Antonio Rovira
ABAlex Butean
Alex Butean
AHArne Høeg
Arne Høeg

1 July 2026 in Revista Mexicana de Física
Verified
Journal Article
Open access
PDF file
DGDavid Espinosa Gómez
David Espinosa Gómez
MSMiguel Moctezuma Sánchez
Miguel Moctezuma Sánchez
Luis Bernardo López-SosaLuis Bernardo López-Sosa
Luis Bernardo López-Sosa
FRFernando Ramirez-Zavaleta
Fernando Ramirez-Zavaleta
Saúl Leonardo Hernández TrujilloSaúl Leonardo Hernández Trujillo
Saúl Leonardo Hernández Trujillo
IGIman Golpour
Iman Golpour
Currently, there is growing interest in improving the thermal efficiency of homes and buildings. It is important to develop models that analyze the thermal behavior of these buildings and suggest improvements to optimize comfort in housing infrastructure. In this work, a thermal model was developed that allows for the estimation of indoor temperatures in rural homes in the state of Michoacán using the electrical analogy method. The proposed methodology is based on three stages: (a) the formulation of a model from an electrical circuit system that is based on physical principles through the heat transfer and energy balance of a simple cubic housing system, where the thermal properties of the roof have been used, such as conductivity, area, thickness and density (b) the analysis of the thermal behavior of three types of houses with cement floors, baked clay brick walls and variable roofs of cement, asbestos sheets and black cardboard sheets, in which case internal temperatures have been recorded using ambient thermometers, and external temperatures using thermocouples and aerial thermography, and (c) the validation of the model through the comparison of the maximum and minimum temperatures per day in the analyzed houses, contrasting the predictions of the model with the experimental data. The results show that the thermal model is functional. It was tested in different homes during March and April 2024, obtaining an average absolute relative error of 4% with respect to the actual temperature of the home. In cases with greater climatic fluctuations and temperature variations on the roofs of the homes studied, errors were less than 10%. The exterior temperatures of the roofs of the homes, as a boundary condition of the model, can be estimated using aerial tomography, which allows the interior temperatures of the types of homes analyzed to be predicted with acceptable errors through non-invasive measurement techniques. It is expected that this tool can be used in the diagnosis of materials and the formulation of strategies that promote room improvements to encourage thermal comfort in rural communities. En la actualidad existe un interés creciente en mejorar la eficiencia térmica de las viviendas y edificios, siendo importante el desarrollo de modelos que analicen el comportamiento térmico de estos inmuebles y sugieran mejoras para optimizar el confort en la infraestructura habitacional. En este trabajo se desarrolló un modelo térmico que permite la estimación de la temperatura interior en viviendas rurales del estado de Michoacán mediante el método de analogías eléctricas. La metodología propuesta se basa en tres etapas: (a) la formulación de un modelo a partir de un sistema de circuito eléctrico que se fundamenta en principios físicos a través de la transferencia de calor y el balance de energía de un sistema de vivienda cúbica simple, donde se han utilizado las propiedades térmicas del techo, como la conductividad, el área, el espesor y la densidad; (b) el análisis del comportamiento térmico de tres tipos de viviendas con piso de cemento, muros de ladrillo de arcilla cocida y techos variables de cemento, lámina de asbesto y láminas de cartón negro, en cuyo caso se han registrado las temperaturas internas mediante termómetros ambientales, y externa mediante termopares y termografía aérea; y (c) la validación del modelo a través de la comparación de las temperaturas máximas y mínimas por día en las viviendas analizadas, contrastando las predicciones del modelo con los datos experimentales. Los resultados muestran que el modelo térmico es funcional. Se probó en distintas viviendas durante los meses de marzo y abril de 2024, obteniendo un error relativo absoluto medio porcentual del 4% respecto a la temperatura real de la vivienda. En los casos con mayores fluctuaciones climatológicas y de variación de temperaturas en los techos de las viviendas estudiadas, se observaron errores menores al 10%. Las temperaturas exteriores de los techos de las viviendas, como condición de frontera del modelo, pueden estimarse mediante tomografía aérea, lo que permite predecir, mediante técnicas de medición no invasivas, las temperaturas interiores de los tipos de viviendas analizadas con errores aceptables. Se espera que esta herramienta pueda utilizarse en el diagnóstico de materiales y la formulación de estrategias que promuevan la mejora de habitaciones para incentivar el confort térmico en comunidades rurales.