Ali Zaidi

Prof. Dr. Ali Zaidi

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2005 in Journal of Composites for Construction
Verified
Journal Article
Closed access
RMRadhouane Masmoudi
Radhouane Masmoudi
AZAli Zaidi
Ali Zaidi
PGPatrick Gérard
Patrick Gérard
Fiber reinforced polymers (FRPs) have a thermal expansion in the transverse direction much higher than in the longitudinal direction and also higher than the thermal expansion of hardened concrete. The difference between the transverse coefficient of thermal expansion of FRP bars and concrete may cause splitting cracks within the concrete under temperature increase and, ultimately, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental investigation to analyze the effect of the ratio of concrete cover thickness to FRP bar diameter (c∕ db ) on the strain distributions in concrete and FRP bars, using concrete cylindrical specimens reinforced with a glass FRP bar and subjected to thermal loading from −30 to +80°C . The experimental results show that the transverse coefficient of thermal expansion of the glass FRP bars tested in this study is found to be equal to 33 (× 10−6 mm∕mm∕°C) , on average and the ratio between the transvers...

18 March 2014 in Polymers
Verified
Journal Article
Open access
PDF file
HBHizia Bellakehal
Hizia Bellakehal
AZAli Zaidi
Ali Zaidi
RMRadhouane Masmoudi
Radhouane Masmoudi
MBMohamed Bouhicha
Mohamed Bouhicha
The large temperature variation has a harmful effect on concrete structures reinforced with fiber reinforced polymer (FRP) bars. This is due to the significant difference between transverse coefficient of thermal expansion of these bars and that of the hardened concrete. This difference generates a radial pressure at the FRP bar/concrete interface, and may cause splitting cracks within concrete. This paper presents results of an experimental and analytical study carried out on FRP-reinforced concrete slabs subjected, simultaneously, to thermal and mechanical loads. The analytical model based on the theory of linear elasticity consists to evaluate combined effects of thermal and mechanical loads on the transverse expansion of FRP bars. Parameters studied in this investigation are the concrete cover thickness, FRP bar diameter, and the temperature variation. The thermal cycles were varied from −30 to +60 °C. Comparisons between analytical and experimental results show that transverse strains predicted from the proposed model are in good correlation with experimental results.

1 January 2013 in Construction and Building Materials
Verified
Journal Article
Closed access
AZAli Zaidi
Ali Zaidi
RMRadhouane Masmoudi
Radhouane Masmoudi
MBMohamed Bouhicha
Mohamed Bouhicha

1 November 2013 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
HBHizia Bellakehal
Hizia Bellakehal
AZAli Zaidi
Ali Zaidi
RMRadhouane Masmoudi
Radhouane Masmoudi
MBMohamed Bouhicha
Mohamed Bouhicha
Flexural behaviour of reinforced-concrete slabs has been widely investigated to characterize properties and behaviour of fibre-reinforced polymer (FRP) materials as reinforcement for concrete structures. However, the short- and long-term thermal effects on FRP bars owing to the significant difference between the bars’ coefficients of thermal expansion in the transverse and longitudinal directions are still to be evaluated and may affect the bond properties and the concrete cover thickness after multiple exposures to freeze–thaw cycles. This paper presents the thermostructural behaviour of one-way concrete slabs reinforced with glass FRP (GFRP) that have previously been subjected to mechanical loads of 20% and 30% of the ultimate flexural capacity of reinforced-concrete slabs, simultaneously with short freeze–thaw cycles. Series tests were conducted on FRP-reinforced concrete slabs 500 mm wide, 195–215 mm thick, and 2500 mm long. The thermal cycles were varied from −30 to 60 °C. Four-point bending tests were conducted up to failure of the slabs. The results show that the thermomechanical load applied before bending tests increases the performance of reinforced-concrete slabs, particularly the concrete shear capacity. The deflection predicted from CSA code and ACI guidelines are very close to those obtained from experimental tests; however, the CSA code overestimates the deflection at the service load. The applied thermal cycles have no big influence on the behaviour before shear failure of concrete slabs reinforced with GFRP bars.

19 October 2011 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AZAli Zaidi
Ali Zaidi
RMRadhouane Masmoudi
Radhouane Masmoudi

26 January 2012 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AZAli Zaidi
Ali Zaidi
RMRadhouane Masmoudi
Radhouane Masmoudi