Rodrigo Resende

Dr. Rodrigo Resende


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2019 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
CSCarlos Soriano‐Souza
Carlos Soriano‐Souza
HVHelder Valiense
Helder Valiense
EMElena Mavropoulos
Elena Mavropoulos
VMVictor Martínez-Zelaya
Victor Martínez-Zelaya
ACAndrea Machado Costa
Andrea Machado Costa
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia

1 November 2020 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
SSSuelen Sartoretto
Suelen Sartoretto
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
RRRodrigo Resende
Rodrigo Resende
ECEduardo Câmara
Eduardo Câmara
BGBruna Ghiraldini
Bruna Ghiraldini
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
Background and Objective: The success rates of dental implants in low-density bone have been reported as a challenge, especially for early or immediate loading in the maxilla posterior area. Nanoscale architecture affects the roughness, surface area, surface energy of the implant and can enhance osseointegration. This study aimed to evaluate the implant-surface topography and biomechanical, histomorphometric, and histological bone responses to a new nanostructured hydroxyapatite surface placed in the iliac crest of sheep. Methods: Ten female sheep (2– 4 years) received 30 implants (n=10/group): HAnano® coated (Epikut Plus®, S.I.N. Implant System, Sao Paulo, SP, Brazil), SLActive (BLX®, Straumann, Basel, Switzerland), and TiUnite (NobelActive®, Nobel Biocare, Göteborg, Sweden) surfaces. Scanning electron microscopy with energy-dispersive spectroscopy evaluated the implant surface topography, the insertion torque value, and resonance frequency analysis evaluated the primary stability, bone-implant contact, and bone-area fraction occupancy were evaluated after 14 and 28 days after implant placement. Results: The surface morphology was considerably comparable between the implant groups’; however, the TiUnite® group presented a remarkable different surface. The SLActive® and TiUnite® groups presented an insertion torque average of 74 (± 8.9) N/cm that was similar to that of HAnano® 72 (± 8.3) N/cm (p > 0.05). The resonance frequency evaluated with Osstell®/SmartPeg® or Penguin®/MulTipeg® showed similar results when assessing implants from the same group. BIC and BAFO significantly increased (p< 0.05) throughout the experimental periods to all groups, but BIC and BAFO values were similar among the implants at the same time point. After 4 weeks, bone-implant contact was higher than 80% of the total length analyzed. New bone occupies around 60% of analyzed area around the implants. Conclusion: HAnano® coated surface promoted comparable osseointegration as SLActive and TiUnite in the sheep model. The three tested surfaces showed comparable osseointegration at the early stages of low-density bone repair in the sheep model.

21 April 2013 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
RRRodrigo Resende
Rodrigo Resende
Gustavo FernandesGustavo Fernandes
Gustavo Fernandes
SSSílvia R. A. Santos
Sílvia R. A. Santos
ARAlexandre Rossi
Alexandre Rossi
ILInayá Lima
Inayá Lima
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia

15 December 2020 in Membranes
Verified
Journal Article
Open access
PDF file
ANAbdu Mansur Dacache Neto
Abdu Mansur Dacache Neto
SSSuelen Sartoretto
Suelen Sartoretto
IDIsabelle Martins Duarte
Isabelle Martins Duarte
RRRodrigo Resende
Rodrigo Resende
AAAdriana Terezinha Neves Novellino Alves
Adriana Terezinha Neves Novellino Alves
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
Mechanical barriers prevent the invasion of the surrounding soft tissues within the bone defects. This concept is known as Guided Bone Regeneration (GBR). The knowledge about the local tissue reaction and the time of degradation of absorbable membranes favors the correct clinical indication. This study aimed to evaluate the biocompatibility and biodegradation of a bovine collagen membrane (Lyostypt®, São Gonçalo, Brazil) and compare it to a porcine collagen membrane (Bio-Gide®) implanted in the subcutaneous tissue of mice, following ISO 10993-6:2016. Thirty Balb-C mice were randomly divided into three experimental groups, LT (Lyostypt®), BG (Bio-Gide®), and Sham (without implantation), and subdivided according to the experimental periods (7, 21, and 63 days). The BG was considered non-irritant at seven days and slight and moderate irritant at 21 and 63 days, respectively. The LT presented a small irritant reaction at seven days, a mild reaction after 21, and a reduction in the inflammatory response at 63 days. The biodegradation of the LT occurred more rapidly compared to the BG after 63 days. This study concluded that both membranes were considered biocompatible since their tissue reactions were compatible with the physiological inflammatory process; however, the Bio-Gide® was less degraded during the experimental periods, favoring the guided bone regeneration process.

6 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
RRRodrigo Resende
Rodrigo Resende
SSSuelen Sartoretto
Suelen Sartoretto
MUMarcelo Jose Uzeda
Marcelo Jose Uzeda
AAAdriana T. N. N. Alves
Adriana T. N. N. Alves
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
The properties of the biodegradation of bone substitutes in the dental socket after extraction is one of the goals of regenerative medicine. This double-blind, randomized, controlled clinical trial aimed to compare the effects of a new bioabsorbable nanostructured carbonated hydroxyapatite (CHA) with a commercially available bovine xenograft (Bio-Oss®) and clot (control group) in alveolar preservation. Thirty participants who required tooth extraction and implant placement were enrolled in this study. After 90 days, a sample of the grafted area was obtained for histological and histomorphometric evaluation and an implant was installed at the site. All surgical procedures were successfully carried out without complications and none of the patients were excluded. The samples revealed a statistically significant increase of new bone formation (NFB) in the CHA group compared with Bio-Oss® after 90 days from surgery (p < 0.05). However, the clot group presented no differences of NFB compared to CHA and Bio-Oss®. The CHA group presented less amount of reminiscent biomaterial compared to Bio-Oss®. Both biomaterials were considered osteoconductors, easy to handle, biocompatible, and suitable for alveolar filling. Nanostructured carbonated hydroxyapatite spheres promoted a higher biodegradation rate and is a promising biomaterial for alveolar socket preservation before implant treatment.

Verified
Journal Article
Open access
PDF file
TVThiago Schneider Werner Vianna
Thiago Schneider Werner Vianna
SSSuelen Sartoretto
Suelen Sartoretto
AAAdriana Terezinha Neves Novellino Alves
Adriana Terezinha Neves Novellino Alves
RRRodrigo Resende
Rodrigo Resende
Carlos Fernando MourãoCarlos Fernando Mourão
Carlos Fernando Mourão
RLRAFAEL LOURO
RAFAEL LOURO
Many biomaterials are used for Bone Morphogenetic Proteins (BMPs) delivery in bone tissue engineering. The BMP carrier system’s primary function is to hold these growth factors at the wound’s site for a prolonged time and provide initial support for cells to attach and elaborate the extracellular matrix for bone regeneration. This study aimed to evaluate the nanostructured carbonated hydroxyapatite microspheres (nCHA) as an rhBMP-2 carrier on rats calvaria. A total of fifteen male Wistar rats were randomly divided into three groups (n = 5): clot (control group), rhBMP-2 associated with collagen membrane (COL/rhBMP-2) or associated with the microspheres (nCHA/rhBMP-2). After 45 days, the calvaria defect samples were evaluated through histological, histomorphometric, and SR-µCT analyses to investigate new-formed bone and connective tissue volume densities. The descriptive histological analysis showed that nCHA/rhBMP-2 improved bone formation compared to other groups. These results were confirmed by histomorphometric and SR-µCT analysis that showed substantially defect area filling with a higher percentage of newly formed (36.24 ± 6.68) bone than those with the COL/rhBMP-2 (0.42 ± 0.40) and Clot (3.84 ± 4.57) (p < 0.05). The results showed that nCHA is an effective carrier for rhBMP-2 encouraging bone healing and an efficient alternative to collagen membrane for rhBMP-2 delivery.