Bruna Ghiraldini

Dr. Bruna Ghiraldini

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RMRafael Coutinho Coutinho Machado
Rafael Coutinho Coutinho Machado
SSSuelen Sartoretto
Suelen Sartoretto
JGJose M. Granjeiro
Jose M. Granjeiro
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
MUMarcelo Jose Uzeda
Marcelo Jose Uzeda
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
Primary implant stability is a prerequisite for successful implant osseointegration. The osseodensification technique (OD) is a non-subtractive drilling technique that preserves the bone tissue, increases osteotomy wall density, and improves the primary stability. This study aimed to investigate the hypothesis that OD, through a wider osteotomy, produces healing chambers (HCs) at the implant-bone interface without impacting low-density bone primary stability. Twenty implants (3.5 × 10 mm) with a nanohydroxyapatite (nHA) surface were inserted in the ilium of ten sheep. Implant beds were prepared as follows: (i) 2.7-mm-wide using subtractive conventional drilling (SCD) technique (n = 10); (ii) 3.8-mm-wide using an OD bur system (n = 10). The sheep were randomized to two groups, with samples collected at either 14-(n = 5) or 28-days (n = 5) post-surgery and processed for histological and histomorphometric evaluation of bone-implant contact (BIC) and bone area fraction occupancy (BAFO). No significant group differences were found with respect to final insertion torque and implant stability quotient (p > 0.050). BIC values were higher for SCD after 14 and 28 days (p < 0.050); however, BAFO values were similar (p > 0.050). It was possible to conclude that the OD technique allowed a wider implant bed preparation without prejudice on primary stability and bone remodeling.

1 November 2020 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
SSSuelen Sartoretto
Suelen Sartoretto
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
RRRodrigo Resende
Rodrigo Resende
ECEduardo Câmara
Eduardo Câmara
BGBruna Ghiraldini
Bruna Ghiraldini
Mônica Diuana Calasans-MaiaMônica Diuana Calasans-Maia
Mônica Diuana Calasans-Maia
Background and Objective: The success rates of dental implants in low-density bone have been reported as a challenge, especially for early or immediate loading in the maxilla posterior area. Nanoscale architecture affects the roughness, surface area, surface energy of the implant and can enhance osseointegration. This study aimed to evaluate the implant-surface topography and biomechanical, histomorphometric, and histological bone responses to a new nanostructured hydroxyapatite surface placed in the iliac crest of sheep. Methods: Ten female sheep (2– 4 years) received 30 implants (n=10/group): HAnano® coated (Epikut Plus®, S.I.N. Implant System, Sao Paulo, SP, Brazil), SLActive (BLX®, Straumann, Basel, Switzerland), and TiUnite (NobelActive®, Nobel Biocare, Göteborg, Sweden) surfaces. Scanning electron microscopy with energy-dispersive spectroscopy evaluated the implant surface topography, the insertion torque value, and resonance frequency analysis evaluated the primary stability, bone-implant contact, and bone-area fraction occupancy were evaluated after 14 and 28 days after implant placement. Results: The surface morphology was considerably comparable between the implant groups’; however, the TiUnite® group presented a remarkable different surface. The SLActive® and TiUnite® groups presented an insertion torque average of 74 (± 8.9) N/cm that was similar to that of HAnano® 72 (± 8.3) N/cm (p > 0.05). The resonance frequency evaluated with Osstell®/SmartPeg® or Penguin®/MulTipeg® showed similar results when assessing implants from the same group. BIC and BAFO significantly increased (p< 0.05) throughout the experimental periods to all groups, but BIC and BAFO values were similar among the implants at the same time point. After 4 weeks, bone-implant contact was higher than 80% of the total length analyzed. New bone occupies around 60% of analyzed area around the implants. Conclusion: HAnano® coated surface promoted comparable osseointegration as SLActive and TiUnite in the sheep model. The three tested surfaces showed comparable osseointegration at the early stages of low-density bone repair in the sheep model.

Verified
Journal Article
Open access
PDF file
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
HSHélio Doyle Pereira da Silva
Hélio Doyle Pereira da Silva
BGBruna Ghiraldini
Bruna Ghiraldini
RSRafael Shinoske Siroma
Rafael Shinoske Siroma
Lavinia Cosmina ArdeleanLavinia Cosmina Ardelean
Lavinia Cosmina Ardelean
Jamil Awad ShibliJamil Awad Shibli
Jamil Awad Shibli
Primary stability is an important factor for dental implant success. In the past years, a new method for bone site preparation was introduced, named osseodensification (OD). OD produces a condensation of the trabecular portion of the bone, increasing bone-to-implant contact and primary stability. This study aims to compare the effect of OD in cylindrical and conical implants to conventional instrumentation. A total of forty implants, divided into four groups, were placed in porcine tibia: cylindrical conventional (1a), cylindrical OD (1b), conical conventional (2a) and conical OD (2b). Each implant was measured for implant stability quotient (ISQ), insertion torque (IT) and removal torque (RT). Group 2b showed the higher values for each of the evaluated parameters; groups 1b and 2b showed better results than 1a and 2a, respectively. Regarding the IT and RT, group 1b achieved higher values than group 2a, but not for ISQ. The inter-group comparison showed significant difference between groups 1a vs 2a, 1a vs 2b and 1b vs 2b for ISQ and 1a vs 1b and 1a vs 2b for RT analysis. OD resulted in improved ISQ, IT and RT of both cylindrical and conical implants.

13 June 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FFFausto Frizzera
Fausto Frizzera
RSRubens Spin-Neto
Rubens Spin-Neto
VPVictor Padilha
Victor Padilha
NNNicolas Nicchio
Nicolas Nicchio
BGBruna Ghiraldini
Bruna Ghiraldini
EJElcio Marcantonio Junior
Elcio Marcantonio Junior
Background: Implant installation with conventional drilling can create buccal bone defects in areas of limited ridge thickness. Implant installation with osseodensification may aid in preventing buccal bone defects in these situations. This in vitro pilot study evaluated the impact of osseodensification on the increase in alveolar ridge thickness and the prevention of buccal peri-implant defects.Methods: Ten fresh pig mandibles with limited bone thickness were selected for use in an experimental randomized split mouth pilot study. Two site-preparation protocols were used: conventional drilling with cutting burs (CTL, n = 10) and osseodensification with Densah® burs (OD, n = 10). After implant bed preparation, 20 implants (4.5 × 10 mm) were placed in the prepared sites and the insertion torque was recorded. Clinical and photographic analysis evaluated ridge thickness and the extent (height, width, and area) of bone defects in the buccal and lingual bone walls following implant placement. Three-dimensional measurements were performed using STL files to analyze the increase in buccal ridge thickness following site preparation and implant placement. The height of the buccal bone defect was considered as the primary outcome of this study. Defect width, area, implant insertion torque, and linear buccal ridge increase after implant site preparation and installation were also assessed. Non-parametric evaluations were carried out with the Mann–Whitney test to verify intergroup differences.Results: There was no statistically significant difference between groups in the baseline ridge thickness. OD presented a significantly higher insertion torque, associated with reduced buccal and lingual bone defect width, in comparison to CTL.Conclusions: The increase in buccal ridge thickness after site preparation and implant placement was significantly higher in OD compared to CTL. Osseodensification increased the ridge thickness through expansion and reduced buccal bone defects after implant installation.

25 October 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
FNFelipe Nunes
Felipe Nunes
POPaula Oliveira
Paula Oliveira
EBEdmara Bergamo
Edmara Bergamo
PKPer Kjellin
Per Kjellin
ANARTHUR B. NOVAES
ARTHUR B. NOVAES
Sergio Scombatti de SouzaSergio Scombatti de Souza
Sergio Scombatti de Souza
This study evaluated the effect of smoke exposure on the expression of genes related to bone metabolism in implants coated with nanohydroxyapatite (NHA). A total of 36 rats were exposed to cigarette smoke for 60 days. The animals were allocated into three groups: machined implants (MAC), dual acid-etched implants (DAE), and NHA-coated implants (NHA). Implants were installed in the left tibia of the rats after 30 days of smoke exposure. The implants were retrieved 7 and 30 days after implantation, and the adjacent bone analyzed using a real-time polymerase chain reaction for gene expression of alkaline phosphatase (ALP), osteopontin (OPN), receptor activator of the nuclear factor kappa ligand (RANKL), osteoprotegerin (OPG), the RANKL/OPG ratio, osteocalcin (OCN) and runt-related transcription factor 2 (Runx2). After 7 days, Runx2, OPN and OPG expression demonstrated significantly higher levels for the NHA surface treatment relative to DAE and MAC surfaces. NHA presented the lowest RANKL and RANKL/OPG levels. After 30 days, NHA-coated implants showed significantly higher levels of Runx2, ALP, OPN, OPG, OC, RANKL and RANKL/OPG relative to DAE and MAC implants. The results indicated a greater osteogenic and high osteoclastic activity around NHA implants, in comparison to DAE and MAC implants.

Verified
Journal Article
Open access
PDF file
JJJosé Augusto Gabarra Júnior
José Augusto Gabarra Júnior
FNFernando Nóbrega
Fernando Nóbrega
POPaula Oliveira
Paula Oliveira
EBEdmara Tatiely Bergamo
Edmara Tatiely Bergamo
UCUislen Cadore
Uislen Cadore
Sergio Scombatti de SouzaSergio Scombatti de Souza
Sergio Scombatti de Souza
Leukocyte–platelet-rich fibrin (L-PRF) contains growth factors that stimulate bone regeneration. This study evaluated the bone repair in a tibia rat model around two implant surfaces in combination or not with L-PRF by assessing microtomographic and histomorphometric parameters. A total of 48 female rats were used in the study, in which 24 received implants with two types of surface treatments (dual acid etched—DAE or nanohydroxyapatite—nanoHA), and the other 24 received the same mini implants with L-PRF, which was collected by cardiac puncture, centrifugated, and inserted in the bone bed. The animals were euthanized 7 and 30 days after implant placement, and the retrieved samples were prepared for microtomographic and histomorphometric (bone-to-implant contact—BIC; and Bone Area Fraction Occupancy—BAFO) analyses. The adhesion of the nanoHA surface onto the implant surface was investigated by insertion and removal in simulated bone medium (Sawbones). The adhesion evaluation revealed that the loss of nanoHA after this procedure (as measured with SEM) from the implant surface was less than 1%. Overall, the nanoHA surface presented more bone in contact and in proximity to the implant, a higher bone surface/tissue volume fraction, a higher number of bone trabeculae, as well as trabecular separation relative to the DAE surface. Such results were more evident when the nanoHA surface was combined with L-PRF and after 30 days in vivo. The nanoHA surface presented higher BAFO when compared to DAE, with or without association with L-PRF. Therefore, implants with a nanoHA surface potentially benefit from the association to L-PRF.