In this article, we introduce a new Stata command to estimate the net survival function and the net cumulative hazard. The command includes graphic facilities. It was designed to have a similar syntax to sts, the Stata command dedicated to estimate survival and related functions. We present two examples to illustrate the use of this new command.
Occupational exoskeletons hold promise in preventing musculoskeletal disorders, but their effectiveness relies on their long-term use by workers. This study aims to characterize the adoption process of occupational exoskeletons by analyzing the experiences of 25 operators. Using a mixed-methods approach, both quantitative and qualitative data were collected before and during a four-week familiarization period. We primarily focused on users' expectations, subjective assessments over time, and initial experiences. Findings elucidate shifts in operators' perceptions of the devices over time. Through their narratives, we highlight how exoskeleton use impact operators' movements and the subsequent adaptations. Operators demonstrated diverse exploratory behaviors, indicating their efforts to get to grips with the effects of exoskeletons in their own ways. This study offers insights into the initial stages of occupational exoskeleton adoption, thus enriching our comprehension of rejection patterns and pathways toward their widespread acceptance.
Objectives: The main challenge in the care of patients with primary antiphospholipid syndrome (APS) or associated to systemic lupus erythematosus (SLE) is to determine whether patients will experience new events that may impair their clinical outcome. Triggering receptor expressed on myeloid cells-1 (TREM-1) is an amplifier of the Toll like receptor (TLR4) pathway, which is involved in APS. Plasma soluble TREM-1 (sTREM-1) levels indicate increased receptor activation and were significantly greater in thrombotic primary APS patients compared to controls. This prospective cohort study investigated the predictive value of plasma sTREM-1 levels at inclusion for the occurrence of thrombotic events or death in patients with APS, antiphospholipid antibodies (aPLs) and/or SLE. Methods: Serum sTREM-1 levels were measured at inclusion in 108 patients with APS, isolated aPL or SLE followed during 46 months. The primary outcomes included thrombosis, death and obstetrical morbidity. The occurrence of the first event of interest and predictors were modeled in a multivariable Cox model. Results: During follow-up, 15 of the 108 patients presented with thromboses (14%), 5 patients died (5%), and 3 women experienced obstetrical morbidities (3%). Elevated serum sTREM-1 levels were an independent predictor for the occurrence of the composite outcome (HR 7.54 [95% CI; 2.44-23.31] p < .001). In addition, sTREM-1 levels were greater in patients with APS than patients with isolated aPL ( p < .01). Conclusion: High levels of sTREM-1 at inclusion predicted the occurrence of a thrombotic and obstetric event or death in patients with aPL and/or SLE. Therefore, sTREM-1 represents a potential new prognostic biomarker in these patients.
Test methods that use pushing forces to evaluate the maximal load capacities of carts in design standards require a flat, smooth and horizontal steel plate and thus do not take into account the real conditions of work. Resistive forces of a single wheel of a cart in a uniform rectilinear motion were measured using a unique test bench with five loads. Forty-four wheels were tested (varying diameters, treads and bearings) with one steel plate and four resilient floor coverings. Based on a linear mixed model, all the following results were significant (p < 0.05). Resistive forces were increased linearly with the load and depended on the characteristics of both the wheel and floor. These forces decreased as the diameter increased. They were important for wheels with sleeve bearings but decreased for cone ball bearings and precision ball bearings. Resistive forces depended on the material of the tread and were higher for solid rubber treads. In contrast, the hardness of the tread had little effect. Resistive forces strongly depended on the hardness of the base foam of resilient floor coverings: the softer the base foam, the higher the resistive forces. Test methods in design standards should be reviewed, using corrective forces based on these present results, to prevent musculoskeletal disorders.
1 September 2015 in Archives des Maladies Professionnelles et de l'Environnement
Skill acquisition is traditionally assessed based on productivity measures, such as Movement Time (MT), which reflect task execution speed. However, movement smoothness may provide additional insights into skill progression by assessing improvements in movement execution. This study evaluated the evolution of both smoothness and productivity in hairdressing following a change of tool. Kinematic recordings of 14 professional hairdressers, novice users of Ringless Scissors [RS], were taken in the laboratory over four half-days of initiation and after 4.5 months of use in the hair salon. Three types of cuts were performed with Traditional Scissors [TS], then with RS. Smoothness [Number of Peaks (NoP); Log DimensionLess Jerk (LDLJ); SPectral ARC length (SPARC)] was assessed for an elementary movement sequence, spanning tool transport to the start of cutting. MT, representing the duration of these sequences, was assessed as a measure of productivity. After introduction of the RS, smoothness decreased and MT increased. With practice, both characteristics improved. After training, SPARC showed comparable smoothness between RS and TS for two of three cutting movements, while LDLJ and NoP remained higher with TS. After 4.5 months, smoothness improved further, with LDLJ and NoP approaching TS values. Although MT was significantly reduced, it remained higher with RS than TS after 4.5 months use in the salon. These results suggest that introduction of a new tool affects not only productivity - MT - but also movement quality - smoothness. The results presented highlight the relevance of smoothness measures in occupational contexts involving motor learning.