Faisal Ahmed

Mr. Faisal Ahmed

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2021 in Eye
Verified
Journal Article
Open access
PDF file
TYTimothy E. Yap
Timothy E. Yap
PZPiero Zollet
Piero Zollet
SHSalman Husein
Salman Husein
MMMohammad M. M. Murad
Mohammad M. M. Murad
SASally Ameen
Sally Ameen
FAFaisal Ahmed
Faisal Ahmed
Objective: To assess the safety and efficacy of endocyclophotocoagulation with phacoemulsification (phaco-ECP) in surgically naive, primary open-angle glaucoma (POAG). Methods: A retrospective case series of patients undergoing phaco-ECP between 2007 and 2017 at a single centre in London, UK. The primary outcome was intraocular pressure (IOP). Secondary outcomes were visual acuity, visual field global indices, topical medications and surgical complications. Failure criteria were: (1) IOP > 21 mmHg or <20% reduction at two consecutive visits, (2) IOP <5 mmHg and (3) further IOP-lowering surgery. Results: Eighty-three eyes from 83 patients were eligible. Pre-operatively, mean IOP (±SD) was 18.4 ± 5.2 mmHg. The mean number of topical agents (±SD) was 2.7 ± 0.9. Mean IOP (±SD) significantly reduced to 14.3 ± 4.7 at 1 year, 14.1 ± 4.0 at 2 years and 13.6 ± 3.7 at 3 years (p < 0.0001). Topical medications were significantly reduced to 1.3 ± 1.2 at 1 year, 1.7 ± 1.2 at 2 years and 1.8 ± 1.3 at 3 years (p < 0.0001). Annual IOP ‘survival’ was 70%, 54% and 45% at year 1, 2 and 3, respectively. Complications included uveitis (6%), macular oedema (2%), IOP spikes (1%) and corneal decompensation (1%) with no episodes of hypotony or retinal detachment. One patient underwent filtration surgery within 3 years (1%). Conclusion: Phaco-ECP facilitates significant IOP lowering and reduction of medication burden in surgically naive POAG requiring cataract extraction. The procedure is relatively safe and without the use of implants and their associated risks.

30 January 2024 in Eye
Verified
Journal Article
Open access
PDF file
MKMonica Kelada
Monica Kelada
ENEduardo M. Normando
Eduardo M. Normando
MCM Francesca Cordeiro
M Francesca Cordeiro
LCLaura Crawley
Laura Crawley
FAFaisal Ahmed
Faisal Ahmed
PBPhilip Bloom
Philip Bloom
Background: Continuous-wave transscleral cyclophotocoagulation (CW-TSCP) is usually reserved for advanced/refractory glaucoma. Micropulse transscleral laser therapy (MPTLT) utilises short energy pulses separated by ‘off’-periods. MPTLT is postulated to have fewer complications, but its relative efficacy is not known. The National Institute for Health and Care Excellence (NICE) has deemed the evidence supporting MPTLT use of inadequate quality, limiting its use to research. This study aims to evaluate MPTLT efficacy and safety compared to CW-TSCP. Methods: This 24-month follow-up retrospective audit included 85 CW-TSCP and 173 MPTLT eyes at a London tertiary referral centre. Primary outcome was success rate at the last follow-up; defined as at least 20% intraocular pressure (IOP) reduction with the same/fewer medications, and IOP between 6 and 18 mmHg. Secondary outcomes were acetazolamide use and success rates per glaucoma type. Safety outcomes were reported as complication rates. Results: By 24-months, mean IOP reduced from 34.6[±1.4]mmHg to 19.0[ ± 3.0]mmHg post-CW-TSCP (p < 0.0001); and from 26.1[±0.8]mmHg to 19.1[±2.2]mmHg post-MPTLT (p < 0.0001). Average IOP decreased by 45.1% post-CW-TSCP, and 26.8% post-MPTLT. Both interventions reduced medication requirements (p ≤ 0.05). More CW-TSCP patients discontinued acetazolamide (p = 0.047). Overall success rate was 26.6% for CW-TSCP and 30.6% for MPTLT (p = 0.83). Only primary closed-angle glaucoma saw a significantly higher success rate following CW-TSCP (p = 0.014). CW-TSCP complication rate was significantly higher than MPTLT (p = 0.0048). Conclusion: Both treatments significantly reduced IOP and medication load. CW-TSCP had a greater absolute/proportionate IOP-lowering effect, but it carried a significantly greater risk of sight-threatening complications. Further prospective studies are required to evaluate MPTLT compared to CW-TSCP.

26 April 2018 in Eye
Verified
Journal Article
Open access
PDF file
APA. M. Porteous
A. M. Porteous
FAFaisal Ahmed
Faisal Ahmed

18 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MFMichael Xiangchen Fu
Michael Xiangchen Fu
ENEduardo M. Normando
Eduardo M. Normando
SLSheila M. H. Luk
Sheila M. H. Luk
MDMira Deshmukh
Mira Deshmukh
FAFaisal Ahmed
Faisal Ahmed
PBPhilip Anthony Bloom
Philip Anthony Bloom
This case-control study aims to compare the efficacy, safety, and postoperative burden of MicroShunt versus trabeculectomy. The first consecutive cohort of MicroShunt procedures (n = 101) was matched to recent historical trabeculectomy procedures (n = 101) at two London hospital trusts. Primary endpoints included changes in intraocular pressure (IOP) and glaucoma medications. Secondary outcome measures included changes in retinal nerve fibre layer (RNFL) thickness, rates of complications, further theatre interventions, and the number of postoperative visits. From the baseline to Month-18, the median [interquartile range] IOP decreased from 22 [17–29] mmHg (on 4 [3–4] medications) to 15 [10–17] mmHg (on 0 [0–2] medications) and from 20 [16–28] mmHg (on 4 [3–4] medications) to 11 [10–13] mmHg (on 0 [0–0] medications) in the MicroShunt and trabeculectomy groups, respectively. IOP from Month-3 was significantly higher in the MicroShunt group (p = 0.006), with an increased number of medications from Month-12 (p = 0.024). There were greater RNFL thicknesses from Month-6 in the MicroShunt group (p = 0.005). The rates of complications were similar (p = 0.060) but with fewer interventions (p = 0.031) and postoperative visits (p = 0.001) in the MicroShunt group. Therefore, MicroShunt has inferior efficacy to trabeculectomy in lowering IOP and medications but provides a better safety profile and postoperative burden and may delay RNFL loss.

25 April 2023 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
BVBeatriz Vidal-Villegas
Beatriz Vidal-Villegas
TYTimothy Yap
Timothy Yap
ENEduardo M Normando
Eduardo M Normando
SASally Ameen
Sally Ameen
MCM Francesca Cordeiro
M Francesca Cordeiro
Purpose: To investigate the impact of the delay in patient appointments caused by the COVID-19 pandemic and the triage system on the glaucomatous disease of patients in a London tertiary hospital. Methods: Observational retrospective study that randomly selected 200 glaucoma patients with more than 3 months of unintended delay for their post-COVID visit and other inclusion and exclusion criteria. Demographic information, clinical data, number of drugs, best-corrected visual acuity (BCVA), intraocular pressure (IOP), visual field (VF) mean deviation (MD), and global peripapillary retinal nerve fibre layer (pRNFL) thickness were obtained from the pre- and post-COVID visit. At the post-COVID visit, the clinical outcomes subjective clinical concern and change of treatment or need for surgery were also annotated. The variables were stratified by glaucoma severity (according to the MD into early, moderate and advanced) and by delay time (more and less than 12 months) and analysed using SPSS. Results: We included 121 eyes (from 71 patients). The median patient age was 74 years (interquartile range -IQR- 15), 54% were males and 52% Caucasians. Different glaucoma types and all glaucoma severities were included. When data was stratified for glaucoma severity, at the pre-COVID visit, significant differences in BCVA, CCT and IOP were observed and there were significantly higher values in the early glaucoma group. The median follow-up delay was 11 months (IQR 8), did not differ between the glaucoma severity groups and did not correlate to the glaucoma severity. At the post-COVID visit, significant differences in BCVA, IOP, and Global pRNFL thickness were observed between the glaucoma severity groups, as lower BCVA and higher IOP and pRNFL thickness were observed in the early glaucoma group. At the post-COVID visit there was cause for concern in 40 eyes: 5 were followed more closely, 22 had a change of treatment and 13 were booked for surgery (3 for cataract and 10 for glaucoma surgery). However, the number of eyes with causes for concern were similar between the glaucoma severity groups and there was no correlation between these clinical outcomes and the delay of the post-COVID visit. The number of topical hypotensive medications increased significantly after the post-COVID visit, higher number of medications were observed in the advanced glaucoma group. When differences of IOP, MD and pRNFL thickness between the pre and post-COVID visit, only the MD difference was significantly different between the glaucoma severity groups because it was higher in the severe group. When data was stratified for delay longer or shorter than 12 months, no differences were observed between the groups except at the pre-COVID visit, when the numbers of patients with MD deviation >−6 dB had longer delay time. When differences in IOP, MD and RNFL thickness were calculated, only the pRNFL thickness showed significant differences between the delay groups, because it was higher in the longer delay group. Finally, when paired analysis of the variables at the pre- and post-COVID visits, stratified by glaucoma severity and delay were conducted, although there were no significant differences in IOP in any group, the BCVA decreased significantly in the overall group and in the longer delay groups, the number of hypotensive drugs increased significantly overall and in the moderate and advanced glaucoma, the MD of the VF worsened significantly in the overall group and in the early glaucoma and longer delay groups and the pRNFL thickness decreased significantly in all groups. Conclusions: We document that delayed care impacts negatively on the glaucomatous disease of our patients because at the post-COVID visit there were reasons for clinical concern in a third of eyes that resulted in change of treatment or surgery. However, these clinical consequences were not related to IOP, glaucoma severity or delay time and reflect that the triage methods implemented worked adequately. The most sensitive parameter to indicate progression in our sample was the pRNFL thickness.

23 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FAFaisal Ahmed
Faisal Ahmed
ENEduardo Normando
Eduardo Normando
SASyed Ahmed
Syed Ahmed
SVSimrun Virdee
Simrun Virdee
AAAhmed Alnahrawy
Ahmed Alnahrawy
Background: We report on the 12-month safety and efficacy outcomes of a new non-valved glaucoma drainage device, the eyePlate-300 (Rheon Medical, Lausanne, Switzerland), in managing refractory glaucoma. Methods: A retrospective review was conducted on consecutive patients over 18 who underwent glaucoma drainage device (GDD) surgery with the eyePlate-300 after a single glaucoma consultation between February 2020 and April 2021, with at least 12 months of documented post-op follow-up. Results: A total of 16 eyes from 15 patients were included. Complete success was observed in 47% of patients and overall success in 83%. The mean IOP decreased from 31.5 mm Hg to 10.7 mm Hg (67% reduction from baseline), and the number of IOP-lowering drops was reduced from 3.1 to 0.7 at one year. The mean BCVA remained stable. No additional IOP-lowering surgeries were required, and no severe sight-threatening complications were noted. Conclusions: The initial one-year results suggest that the eyePlate could be a safe and effective device for reducing IOP in an ethnically diverse refractory glaucoma population. Further follow-up is necessary to determine the long-term safety and efficacy.