Ahmed Alnahrawy

Dr. Ahmed Alnahrawy

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FAFaisal Ahmed
Faisal Ahmed
ENEduardo Normando
Eduardo Normando
SASyed Ahmed
Syed Ahmed
SVSimrun Virdee
Simrun Virdee
AAAhmed Alnahrawy
Ahmed Alnahrawy
Background: We report on the 12-month safety and efficacy outcomes of a new non-valved glaucoma drainage device, the eyePlate-300 (Rheon Medical, Lausanne, Switzerland), in managing refractory glaucoma. Methods: A retrospective review was conducted on consecutive patients over 18 who underwent glaucoma drainage device (GDD) surgery with the eyePlate-300 after a single glaucoma consultation between February 2020 and April 2021, with at least 12 months of documented post-op follow-up. Results: A total of 16 eyes from 15 patients were included. Complete success was observed in 47% of patients and overall success in 83%. The mean IOP decreased from 31.5 mm Hg to 10.7 mm Hg (67% reduction from baseline), and the number of IOP-lowering drops was reduced from 3.1 to 0.7 at one year. The mean BCVA remained stable. No additional IOP-lowering surgeries were required, and no severe sight-threatening complications were noted. Conclusions: The initial one-year results suggest that the eyePlate could be a safe and effective device for reducing IOP in an ethnically diverse refractory glaucoma population. Further follow-up is necessary to determine the long-term safety and efficacy.

19 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MAMohammad Zeyad Mohammad Ayoub
Mohammad Zeyad Mohammad Ayoub
AAAhmed Alnahrawy
Ahmed Alnahrawy
Background/Objectives: This paper will compare the outcomes—safety and efficacy—of three minimally invasive glaucoma surgeries (MIGSs),the Hydrus Microstent, iStent, and Gonioscopy-Assisted Transluminal Trabeculotomy (GATT), for intraocular pressure (IOP) reduction in patients with primary open-angle glaucoma (POAG). Methods: A literature search of Ovid Medline and Embase identified studies evaluating the Hydrus, iStent, and GATT. Data on IOP reduction, medication use, and complications were analyzed. Results: Studies show the Hydrus, iStent, and GATT reduce IOP and medication burden in POAG patients, with some complications. For the Hydrus, studies showed 37.09% (27.5 ± 4.4 to 17.3 ± 3.7 mmHg) and 25% (16.8 to 12.6 mmHg) IOP reduction. Meanwhile, medication burden decreased from 2.5 ± 0.7 to 1.0 and from 2.1 to 1.15. For the iStent, studies showed a 36.39% (21.1 to 13.4 mmHg) and 8.19% (17.1 to 15.7 mmHg) IOP drop. Medication burden decreased from 2.87 to 1.24 and from 1.7 to 0.26. For GATT, studies showed a 49.33% (27.70 ± 10.30 to 14.04 ± 3.75) and 39.09% (26.40 ± 6.37 to 16.08 ± 2.38) IOP drop. Medication burden reduced from 3.73 ± 0.98 to 1.82 ± 1.47 and from 3.12 ± 0.80 to 0.45 ± 0.96. Conclusions: The Hydrus, iStent, and GATT are effective alternatives to trabeculectomy for mild to moderate POAG. They reduce and control IOP and dependence on medications with manageable safety profiles. In all three options, there were some clinically significant complications based on the p-value. For the Hydrus, it was PAS. For the iStent, they were PAS, FB sensation, IOP spikes, and microhyphema. For GATT, it was IOP spikes. However, further long-term studies, especially randomized controlled trials, are needed to support these results.

1 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
BSBharpoor Singh
Bharpoor Singh
ASAndrew James Swampillai
Andrew James Swampillai
MUMrudula Utukuri
Mrudula Utukuri
ENEduardo M. Normando
Eduardo M. Normando
AMAhmed Mazrouaa
Ahmed Mazrouaa
FAFaisal Ahmed
Faisal Ahmed
Background/Objectives: We introduce a new surgical technique for inserting the eyePlate-300—a glaucoma drainage device (GDD). The flexibility of the eyePlate-300 allows for folding and insertion through a smaller conjunctival incision. The procedure is termed minimally invasive tube surgery (MITS). Methods: We performed a retrospective analysis of thirteen eyes to assess the efficacy of the MITS technique in a large London tertiary teaching eye hospital with 12 months follow-up. The primary outcome was complete success: defined as ‘IOP > 5 mmHg, <21 mmHg and off drops’. Secondary outcomes: best corrected visual acuity at 12 months, complications, a reduction in the number of drops and need for further pressure-lowering surgery. Results: Twelve eyes (92%) achieved a lower IOP. The mean pre-operative IOP was 35.69 mmHg (20–53 mmHg); post-operatively, it was reduced to 11.08 mmHg (5–20 mmHg) (p < 0.001). The mean pre-operative drops were 3.462 (3–4), reducing to 0.85 (0–3) at 12 months (p < 0.001). There was no change in the mean BCVA. No intraoperative complications were recorded, and no further IOP lowering surgeries were required. Conclusions: The MITS technique facilitates the implantation of a glaucoma drainage device through a smaller, less traumatic incision. Preliminary one-year data suggest that the procedure may be safe and effective.