Repeatable patient positioning is key to minimising the burden on planning radiotherapy treatment. There are very few materials commercially available which are suitable for use in all common imaging and treatment modalities such as magnetic resonance imaging (MRI), X-Ray computed tomography (CT) and radiotherapy. In this article, we present several such materials based on woven natural fibres embedded in a range of different resin materials which are suitable for such applications. By investigating a range of resins and natural fibre materials in combination and evaluating their performance in terms of MRI and X-Ray imaging, we show that a woven cotton material impregnated with a two-part epoxy resin provides a 15% improvement in passage of X-Rays and has no impact on the MRI signal (unlike the 40% MRI signal attenuation from carbon fibre), whilst also retaining a flexural modulus up to 71% of that of carbon fibre. These results demonstrate that natural fibre composites produced using such materials provide desirable properties for use in patient support and positioning devices for multi-modal imaging, without the need to significantly compromise on the strength of the material.
Background: Magnetic resonance imaging (MRI) of the colonic response to a macrogol challenge drink can be used to assess the mechanisms underlying severe constipation. We measured the intrasubject reproducibility of MRI measures of colonic function to aid their implementation as a possible clinical test.Methods: Healthy participants attended for MRI on two occasions (identical protocols, minimum 1 week apart). They underwent a fasted scan and then consumed the macrogol drink. Subjects were scanned at 60 and 120 minutes, with maximum value reached used for comparison. The colonic volume, water content, mixing of colonic content and the movement of the colon walls were measured. Coefficients of variation and intraclass correlation coefficients (ICC) were calculated.Results: Twelve participants completed the study: nine female, mean age 26 years (SD 5) and body mass index 24.8 kg/m2 (SD 3.2). All measures consistently increased above baseline following provocation with macrogol. The volume, water content and content mixing had good intrasubject reproducibility (ICC volume = 0.84, water content = 0.93, mixing = 0.79, P < .001). With the wall movement, the response to the challenge was generally large, but more variable between visits resulting in a lower ICC overall (ascending colon = 0.65, descending colon = 0.76, P < .001).Conclusions: The colonic response to the macrogol stimulus as assessed by MRI is heterogeneous but large compared to baseline, with moderate to good reproducibility, making the test suitable to study potential pathologies underlying GI disorders such as constipation. More data are needed to better define the normal range for comparison with patient groups who may have both hypo‐ and hypermotile responses.
In this research, resorbable phosphate-based glass (PBG) compositions were developed using varying modifier oxides including iron (Fe2O3), copper (CuO), and manganese (MnO2), and then processed via a rapid single-stage flame spheroidisation process to manufacture dense (i.e., solid) and highly porous microspheres. Solid (63–200 µm) and porous (100–200 µm) microspheres were produced and characterised via SEM, XRD, and EDX to investigate their surface topography, structural properties, and elemental distribution. Complementary NMR investigations revealed the formation of Q2, Q1, and Q0 phosphate species within the porous and solid microspheres, and degradation studies performed to evaluate mass loss, particle size, and pH changes over 28 days showed no significant differences among the microspheres (63–71 µm) investigated. The microspheres produced were then investigated using clinical (1.5 T) and preclinical (7 T) MRI systems to determine the R1 and R2 relaxation rates. Among the compositions investigated, manganese-based porous and solid microspheres revealed enhanced levels of R2 (9.7–10.5 s−1 for 1.5 T; 17.1–18.9 s−1 for 7 T) and R1 (3.4–3.9 s−1 for 1.5 T; 2.2–2.3 s−1 for 7 T) when compared to the copper and iron-based microsphere samples. This was suggested to be due to paramagnetic ions present in the Mn-based microspheres. It is also suggested that the porosity in the resorbable PBG porous microspheres could be further explored for loading with drugs or other biologics. This would further advance these materials as MRI theranostic agents and generate new opportunities for MRI contrast-enhancement oral-delivery applications.
Metabolic dysfunction-associated steatotic liver disease (MASLD) is the leading cause of chronic liver disease, affecting over 30% of adults worldwide. Emerging evidence suggests that dietary fibre, particularly pectin, may improve metabolic health by modulating inflammation, gut microbiota composition, and intestinal permeability. However, controlled human studies in MASLD are limited. This study aims to evaluate the effect of pectin supplementation on systemic inflammation, gut microbiome, and metabolic health in patients with MASLD. This single-centre, double-blind, randomised, placebo-controlled dietary intervention will be conducted at Nottingham University Hospitals NHS Trust in partnership with the University of Nottingham. Thirty adults with MASLD will be randomised (1:1) to receive either 15g/day Low-methoxyl (LM) pectin or a matched placebo for six weeks. Each participant will attend baseline and post-intervention visits during which anthropometric data, fasting blood samples, and stool samples will be collected. FibroScan® assessments will be performed for all participants at both visits to quantify liver stiffness and steatosis. Twenty-two participants will take part in a magnetic resonance imaging (MRI) sub-study to evaluate hepatic and intestinal characteristics at baseline and post-intervention. Laboratory analyses will include liver function, lipid, glycemic, and inflammatory markers, alongside profiling of gut microbiota composition and short-chain fatty acids. This is the first randomised controlled study to evaluate the mechanistic effects of pectin supplementation on inflammation, gut microbiome composition, and metabolic outcomes in MASLD. The results may generate novel evidence on the role of soluble fibre in modulating the gut-liver axis and support the development of scalable, nutrition-based interventions to improve metabolic and hepatic health in this population. The trial was registered on ClinicalTrials.gov (Identifier: NCT07093346).
Objective. Magnetic resonance elastography (MRE) is widely adopted as a biomarker of liver fibrosis. However, in vivo MRE accuracy is difficult to assess. Approach. Finite element model (FEM) simulation was employed to evaluate liver MRE accuracy and inform methodological optimisation. MRE data was simulated in a 3D FEM of the human torso including the liver, and compared with spin-echo echo-planar imaging MRE acquisitions. The simulated MRE results were compared with the ground truth magnitude of the complex shear modulus (∣ G *∣) for varying: (1) ground truth liver ∣ G *∣; (2) simulated imaging resolution; (3) added noise; (4) data smoothing. Motion and strain-based signal-to-noise (SNR) metrics were evaluated on the simulated data as a means to select higher-quality voxels for preparation of acquired MRE summary statistics of ∣ G *∣. Main results. The simulated MRE accuracy for a given ground truth ∣ G *∣ was found to be a function of imaging resolution, motion-SNR and smoothing. At typical imaging resolutions, it was found that due to under-sampling of the MRE wave-field, combined with motion-related noise, the reconstructed simulated ∣ G *∣ could contain errors on the scale of the difference between liver fibrosis stages, e.g. 54% error for ground truth ∣ G *∣ = 1 kPa. Optimum imaging resolutions were identified for given ground truth ∣ G *∣ and motion-SNR levels. Significance. This study provides important knowledge on the accuracy and optimisation of liver MRE. For example, for motion-SNR ≤ 5, to distinguish between liver ∣ G *∣ of 2 and 3 kPa (i.e. early-stage liver fibrosis) it was predicted that the optimum isotropic voxel size is 4–6 mm.