Background: Coronavirus disease 2019 (COVID-19) infection is associated with a coagulopathy with high incidence of venous thrombo-embolism. However, bleeding risk is also significant, causing difficulty in initiating and adjusting anticoagulation therapy in case of suspected thrombi. Cardiac masses can be challenging to be identified properly in the context of this disease. The use of bedside contrast echocardiography (CE) can be of a great value in this situation decreasing procedure-related risk and allowing proper diagnosis and management of a cardiac mass. Cases summary: We present two cases who were admitted with severe COVID-19 infection. Both cases had additional risk factors for hypercoagulability. Un-enhanced echocardiography was performed and revealed right ventricular (RV) dysfunction with a suspected RV mass. The use of bedside CE could confirm a RV thrombus in the first case and exclude it in the second case. Hence, anticoagulation therapy could be adjusted accordingly in both patients. Discussion: Coronavirus disease 2019 infection is associated with peripheral thrombo-embolism and cardiac thrombi. Given the critical condition of many patients affected by COVID-19, imaging for thrombo-embolic events is often restricted. With the use of bedside CE, cardiac masses may be correctly identified, aiding proper adjustment of anticoagulation therapy.
1 December 2025 in Radiology: Cardiothoracic Imaging
This review highlights the role of multimodality imaging techniques in the management of hypertrophic cardiomyopathy, emphasizing their contributions to precise and early diagnosis, prognostic stratification, and treatment planning.
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur at a rate of around 4–8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post-procedure X-ray that would have delineated other serious complications. We present a case where the right ventricular lead was placed in the coronary sinus, which resulted in the loss of pacing capture with further syncope after the pacemaker implant. This was apparent in the post-procedure electrocardiogram (ECG) with right bundle branch pacing and the lead was repositioned in the right ventricular apex the following day. Furthermore, the patient was discharged home without a chest X-ray (CXR), and she represented a week later with a haemo-pneumothorax and pericardial effusion. A chest drain was placed and was discharged after a slow recovery following several complications that could have been avoidable.
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur with a rate of around 3-8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post procedure X-ray that would have delineated other serious complications. An eighty-seven-year-old female patient presented with syncope and documented high grade atrioventricular block. She had a dual chamber pacemaker implant, after which she had another episode of syncope with loss of pacing capture. This was rectified by ventricular lead repositioning that resulted in consistent ventricular pacing. A week later, she was re-admitted with worsening dyspnoea and fatigue. Chest X-ray (CXR) and CT revealed haemopericardium and haemothorax and she was treated with a chest drain and conservatively managed for pericardial effusion. She had a slow recovery and was discharged home after treatment with no further symptoms during follow up in pacing clinic. This case emphasises the importance of meticulous assessment during and after pacemaker implantation.