Permanent pacemaker implantation is a low-risk procedure. However, complications may occur at a rate of around 4–8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post-procedure X-ray that would have delineated other serious complications. We present a case where the right ventricular lead was placed in the coronary sinus, which resulted in the loss of pacing capture with further syncope after the pacemaker implant. This was apparent in the post-procedure electrocardiogram (ECG) with right bundle branch pacing and the lead was repositioned in the right ventricular apex the following day. Furthermore, the patient was discharged home without a chest X-ray (CXR), and she represented a week later with a haemo-pneumothorax and pericardial effusion. A chest drain was placed and was discharged after a slow recovery following several complications that could have been avoidable.
Permanent pacemaker implantation is a low-risk procedure. However, complications may occur with a rate of around 3-8%. We present a case where initial implantation resulted in complications that could have been avoided by meticulous assessment of lead position in different projections and early post procedure X-ray that would have delineated other serious complications. An eighty-seven-year-old female patient presented with syncope and documented high grade atrioventricular block. She had a dual chamber pacemaker implant, after which she had another episode of syncope with loss of pacing capture. This was rectified by ventricular lead repositioning that resulted in consistent ventricular pacing. A week later, she was re-admitted with worsening dyspnoea and fatigue. Chest X-ray (CXR) and CT revealed haemopericardium and haemothorax and she was treated with a chest drain and conservatively managed for pericardial effusion. She had a slow recovery and was discharged home after treatment with no further symptoms during follow up in pacing clinic. This case emphasises the importance of meticulous assessment during and after pacemaker implantation.
Anomalous origin of the left main coronary artery from the right sinus of Valsalva (ALCA-RSV) is exceedingly rare yet complicates emergency angioplasty for ST-segment elevation myocardial infarction. We describe 2 ST-segment elevation myocardial infarction patients in whom ALCA-RSV was identified during primary percutaneous coronary intervention. Despite procedural challenges, timely revascularization was achieved using customized access, catheter strategies, and adjunctive devices. Postprocedural computed tomography coronary angiography excluded malignant courses. Both patients achieved positive outcomes. ALCA-RSV, while exceptionally uncommon, is associated with sudden cardiac death and procedural difficulties during percutaneous coronary intervention. Early identification, precise anatomical imaging, and adaptable techniques are key to successful management. This series contributes to limited existing literature, underscoring that favorable results are possible with tailored intervention strategies. ALCA-RSV complicates emergency angioplasty and necessitates adjusted strategies to achieve revascularization. Multimodality imaging aids risk assessment and delineates malignant from benign courses.