Michael Lehnert

Dr. Michael Lehnert

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Biomolecular Detection and Quantification
Verified
Journal Article
Open access
SWS. Wadle
S. Wadle
MLMichael Lehnert
Michael Lehnert
SRS. Rubenwolf
S. Rubenwolf
RZR. Zengerle
R. Zengerle
FSF. von Stetten
F. von Stetten
Primer and probe sequence designs are among the most critical input factors in real-time polymerase chain reaction (PCR) assay optimization. In this study, we present the use of statistical design of experiments (DOE) approach as a general guideline for probe optimization and more specifically focus on design optimization of label-free hydrolysis probes that are designated as mediator probes (MPs), which are used in reverse transcription MP PCR (RT-MP PCR). The effect of three input factors on assay performance was investigated: distance between primer and mediator probe cleavage site; dimer stability of MP and target sequence (influenza B virus); and dimer stability of the mediator and universal reporter (UR). The results indicated that the latter dimer stability had the greatest influence on assay performance, with RT-MP PCR efficiency increased by up to 10% with changes to this input factor. With an optimal design configuration, a detection limit of 3-14 target copies/10 μl reaction could be achieved. This improved detection limit was confirmed for another UR design and for a second target sequence, human metapneumovirus, with 7-11 copies/10 μl reaction detected in an optimum case. The DOE approach for improving oligonucleotide designs for real-time PCR not only produces excellent results but may also reduce the number of experiments that need to be performed, thus reducing costs and experimental times.

20 May 2011 in Langmuir
Verified
Journal Article
Closed access
MLMichael Lehnert
Michael Lehnert
MGMiriam Gorbahn
Miriam Gorbahn
CRChristopher Rosin
Christopher Rosin
MKMarcus Klein
Marcus Klein
IKIngo Koeper
Ingo Koeper
MVMichael Veith
Michael Veith

20 May 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PJPeter Juelg
Peter Juelg
MSMara Specht
Mara Specht
EKElena Kipf
Elena Kipf
MLMichael Lehnert
Michael Lehnert
CECornelia Eckert
Cornelia Eckert
NPNils Paust
Nils Paust
We introduce a new concept for centrifugal microfluidics that enables fully automated serial dilution generation without any additional means besides temperature control. The key feature is time-independent, serial valving of mixing chambers by fill-level-coupled temperature change rate (FLC-TCR) actuated valving. The automated dilution is realized under continuous rotation which enables reliable control of wetting liquids without the need for any additional fabrication steps such as hydrophobic coating. All fluidic features are implemented in a monolithic fashion and disks are manufactured by foil thermoforming for scalable manufacturing. The new valving concept is demonstrated to reliably prevent valving if the diluted sample is not added to the mixing chamber (n = 30) and ensure valving if the dilution stage is completed (n = 15). The accuracy and precision of automated serial dilutions are verified by on-disk generation of qPCR standard curve dilutions and compared with manually generated reference dilutions. In a first step, the 5-log-stage standard curves are evaluated in a commercial qPCR thermocycler revealing a linearity of R2 ≥ 99.92% for the proposed LabDisk method vs. R2 ≥ 99.67% in manual reference dilutions. In a second step, the disk automated serial dilutions are combined with on-disk qPCR thermocycling and readout, both inside a LabDisk player. A 4-log-stage linearity of R2 ≥ 99.81% and a sensitivity of one leukemia associated ETV6-RUNX1 mutant DNA copy in a background of 100 000 wild-type DNA copies are achieved.

26 June 2018 in Analytical Methods
Verified
Journal Article
Open access
PDF file
MLMichael Lehnert
Michael Lehnert
EKElena Kipf
Elena Kipf
FSFranziska Schlenker
Franziska Schlenker
NBNadine Borst
Nadine Borst
RZRoland Zengerle
Roland Zengerle
FSFelix von Stetten
Felix von Stetten
In this study we optimised the fluorescence signal generation of contact quenched universal reporter oligonucleotides.

1 August 2012 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
MGMiriam Gorbahn
Miriam Gorbahn
MKMarcus O. Klein
Marcus O. Klein
MLMichael Lehnert
Michael Lehnert
TZThomas Ziebart
Thomas Ziebart
DBDan Brüllmann
Dan Brüllmann
MVMichael Veith
Michael Veith

14 April 2015 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
PKPeer Kämmerer
Peer Kämmerer
MLMichael Lehnert
Michael Lehnert
BABilal Al-Nawas
Bilal Al-Nawas
VKVinay V Kumar
Vinay V Kumar
SHSebastien Hagmann
Sebastien Hagmann
MVMichael Veith
Michael Veith