Primer and probe sequence designs are among the most critical input factors in real-time polymerase chain reaction (PCR) assay optimization. In this study, we present the use of statistical design of experiments (DOE) approach as a general guideline for probe optimization and more specifically focus on design optimization of label-free hydrolysis probes that are designated as mediator probes (MPs), which are used in reverse transcription MP PCR (RT-MP PCR). The effect of three input factors on assay performance was investigated: distance between primer and mediator probe cleavage site; dimer stability of MP and target sequence (influenza B virus); and dimer stability of the mediator and universal reporter (UR). The results indicated that the latter dimer stability had the greatest influence on assay performance, with RT-MP PCR efficiency increased by up to 10% with changes to this input factor. With an optimal design configuration, a detection limit of 3-14 target copies/10 μl reaction could be achieved. This improved detection limit was confirmed for another UR design and for a second target sequence, human metapneumovirus, with 7-11 copies/10 μl reaction detected in an optimum case. The DOE approach for improving oligonucleotide designs for real-time PCR not only produces excellent results but may also reduce the number of experiments that need to be performed, thus reducing costs and experimental times.
We introduce a new concept for centrifugal microfluidics that enables fully automated serial dilution generation without any additional means besides temperature control. The key feature is time-independent, serial valving of mixing chambers by fill-level-coupled temperature change rate (FLC-TCR) actuated valving. The automated dilution is realized under continuous rotation which enables reliable control of wetting liquids without the need for any additional fabrication steps such as hydrophobic coating. All fluidic features are implemented in a monolithic fashion and disks are manufactured by foil thermoforming for scalable manufacturing. The new valving concept is demonstrated to reliably prevent valving if the diluted sample is not added to the mixing chamber (n = 30) and ensure valving if the dilution stage is completed (n = 15). The accuracy and precision of automated serial dilutions are verified by on-disk generation of qPCR standard curve dilutions and compared with manually generated reference dilutions. In a first step, the 5-log-stage standard curves are evaluated in a commercial qPCR thermocycler revealing a linearity of R2 ≥ 99.92% for the proposed LabDisk method vs. R2 ≥ 99.67% in manual reference dilutions. In a second step, the disk automated serial dilutions are combined with on-disk qPCR thermocycling and readout, both inside a LabDisk player. A 4-log-stage linearity of R2 ≥ 99.81% and a sensitivity of one leukemia associated ETV6-RUNX1 mutant DNA copy in a background of 100 000 wild-type DNA copies are achieved.