This work describes the application of the Agave salmiana cuticle as a new protonic exchange biological membrane (0.080 ± 0.001 mm thickness). Different chemical, electrochemical and mechanical treatments were evaluated to stimulate the ionic exchange properties of the cuticle. Thermal treatment was adequate for its application in a two-chamber electrolyzer. Under optimal conditions an ionic conductivity value of 10 ± 3 mS cm−1 was obtained; this value is similar to the value achieved using a Nafion membrane. The thermally-activated bio-membrane was also evaluated in a fuel cell, where the highest potential was obtained using methanol and hydrogen (0.46 ± 0.01 V). This result makes the Agave salmiana cuticle a competitive choice to replace the commercial membrane. Its surface morphology and their functional groups were evaluated through scanning electron microscopy (SEM), infrared spectroscopy and impedance spectroscopy. This thermally-treated Agave salmiana cuticle is an ecofriendly alternative to replace Nafion membranes in electrolyzer and fuel cells.
A simple, fast, and low-cost pre-concentration methodology based on the application of multi-template molecularly imprinted polymers (mt-MIP) in a solid-phase extraction system coupled with capillary electrophoresis was developed for the determination of naproxen, diclofenac, and ibuprofen in environmental water samples. A systematic study of the mt-MIP composition was conducted using a second-order simplex lattice experiment design (fraction of the functional monomer methacrylic acid (MAA), the total moles of functional monomers, and the total moles of the cross-linker agent). The optimal mt-MIP, consisting of 0.025 mmol of each analyte, with 2.40 mmol of methacrylic acid (MAA) and 3.60 mmol of 4-vinylpyridine (4VP) and 23.00 mmol of the cross-linker agent (EGDMA), was coupled to an SPE system under the optimal conditions: pH = 3.5; 20 mg of mt-MIP; and an eluent (MeOH/NaOH [0.001]). This methodology provides limits of detection from 3.00 to 12.00 µg L−1 for the studied NSAIDs. The methodology’s precision was evaluated in terms of inter- and intra-day repeatability, with %RSD < 10% in all cases. Finally, the proposed method can be successfully applied in the analysis of environmental water samples (bottle, tap, cistern, well, and river water samples), which demonstrates the developed method’s robustness.
A simple, fast, and low-cost pre-concentration methodology based on the application of solid-phase extraction coupled to layered double hydroxides (LDHs) and capillary electrophoresis was developed for the determination of naproxen (NPX), diclofenac (DFC), and ibuprofen (IBP) in environmental sample waters. A systematic study of the LDH composition was designed, including the effects of interlayer anions (NO3−, Cl−, CO32−, BenO−, and SDS−) and the effect of molar ratio (Mg:Al). The optimal composition of MgAl/Cl−-LDH (Mg:Al; 1.5:1.0) was coupled to an SPE system: pH (neutral pH), LDH amount (15 mg), and extraction capacity ranged from 79.71 to 83.11% for the three anti-inflammatory non-steroidal agents analyzed. A recovery rate of up to 80.87% was obtained when 0.01 M chloride acid in methanol was used as the eluent and 50 mL of sample was used. Under optimal conditions, the linear range of the calibration curve ranges from 18.02 to 200 μg L−1, with limits of detection ranging from 6.03 to 18.02 μg L−1 for the three NSAIDs. The precision of the methodology was evaluated in terms of inter- and intra-day repeatability, with %RSD < 10% in all cases. The proposed method was applied to analyze environmental water samples (bottle, tap, cistern, well, and river water samples). The developed method is a robust technique capable of combining with other analytical methods to quantitatively determine anti-inflammatory non-steroidal agents.
Aflatoxin B1 (AFB1) is one of the most dangerous mycotoxins found in food, necessitating the development of precise and reliable methodologies for its detection. In this study, a novel electrochemical sensor based on a molecularly imprinted polymer (MIP) integrated with a carbon-paste electrode was developed for the voltammetric determination of AFB1. The innovative aspect of this work lies in the use of methacrylic acid (MAA) as the functional monomer, which enhances the sensor’s selectivity and binding affinity. The developed electrochemical sensor exhibited a linear response range from 20.8 to 80 ng/L, with a limit of detection (LOD) of 2.31 ng/L and a sensitivity of 19.83 µA (ng/L)−1 cm−2. The sensor demonstrated outstanding analytical performance, with reproducibility and repeatability yielding relative standard deviations (RSDs) of 3.24% and 1.41%, respectively. To validate the sensor’s practical applicability, its performance was tested in real samples of corn and wheat using the standard addition method. Samples were prepared following official Mexican standard methods. Detected AFB1 concentrations were 0.0147 μg/L and 0.0138 μg/L for corn and wheat, respectively. A statistical comparison using the Student’s t-test confirmed no significant matrix effects, underscoring the high selectivity and accuracy of the MIP-modified sensor. This work introduces a highly selective, sensitive, and reproducible methodology for AFB1 detection, which could significantly advance food safety monitoring.
The benzodiazepines are essential drugs used in medicine for anxiolytic, sedative, and hypnotic effects. According to the World Health Organization, the benzodiazepines are the most prescribed hypnotic drugs in the last decade (2010 at time), and their inappropriate use can damage the environment and human health. The availability of efficient analytical methods is crucial for the determination of these drugs in a complex matrix such as biological samples in clinical settings. In the last decade, several methods have been developed and have been applied to the detection and determination of benzodiazepines or their derivates. The present manuscript reviews selective and sensitive methodologies based on chromatographic, electrophoretic, and electrochemical systems for the determination of benzodiazepines in biological samples, covering the time of the last years and providing detailed information on sample pretreatment and instrumental conditions.