A simple, fast, and low-cost pre-concentration methodology based on the application of multi-template molecularly imprinted polymers (mt-MIP) in a solid-phase extraction system coupled with capillary electrophoresis was developed for the determination of naproxen, diclofenac, and ibuprofen in environmental water samples. A systematic study of the mt-MIP composition was conducted using a second-order simplex lattice experiment design (fraction of the functional monomer methacrylic acid (MAA), the total moles of functional monomers, and the total moles of the cross-linker agent). The optimal mt-MIP, consisting of 0.025 mmol of each analyte, with 2.40 mmol of methacrylic acid (MAA) and 3.60 mmol of 4-vinylpyridine (4VP) and 23.00 mmol of the cross-linker agent (EGDMA), was coupled to an SPE system under the optimal conditions: pH = 3.5; 20 mg of mt-MIP; and an eluent (MeOH/NaOH [0.001]). This methodology provides limits of detection from 3.00 to 12.00 µg L−1 for the studied NSAIDs. The methodology’s precision was evaluated in terms of inter- and intra-day repeatability, with %RSD < 10% in all cases. Finally, the proposed method can be successfully applied in the analysis of environmental water samples (bottle, tap, cistern, well, and river water samples), which demonstrates the developed method’s robustness.
A simple, fast, and low-cost pre-concentration methodology based on the application of solid-phase extraction coupled to layered double hydroxides (LDHs) and capillary electrophoresis was developed for the determination of naproxen (NPX), diclofenac (DFC), and ibuprofen (IBP) in environmental sample waters. A systematic study of the LDH composition was designed, including the effects of interlayer anions (NO3−, Cl−, CO32−, BenO−, and SDS−) and the effect of molar ratio (Mg:Al). The optimal composition of MgAl/Cl−-LDH (Mg:Al; 1.5:1.0) was coupled to an SPE system: pH (neutral pH), LDH amount (15 mg), and extraction capacity ranged from 79.71 to 83.11% for the three anti-inflammatory non-steroidal agents analyzed. A recovery rate of up to 80.87% was obtained when 0.01 M chloride acid in methanol was used as the eluent and 50 mL of sample was used. Under optimal conditions, the linear range of the calibration curve ranges from 18.02 to 200 μg L−1, with limits of detection ranging from 6.03 to 18.02 μg L−1 for the three NSAIDs. The precision of the methodology was evaluated in terms of inter- and intra-day repeatability, with %RSD < 10% in all cases. The proposed method was applied to analyze environmental water samples (bottle, tap, cistern, well, and river water samples). The developed method is a robust technique capable of combining with other analytical methods to quantitatively determine anti-inflammatory non-steroidal agents.