Chunjiang Wei

Dr. Chunjiang Wei


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Robert MauRobert Mau
Robert Mau
TEThomas Eickner
Thomas Eickner
GJGabor Juettner
Gabor Juettner
Ziwen GaoZiwen Gao
Ziwen Gao
CWChunjiang Wei
Chunjiang Wei
Hermann SeitzHermann Seitz
Hermann Seitz
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm × 0.95 mm × 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). Each implant has a handle (~3.00 mm × 1.00 mm × 0.30 mm) that can be used to hold the implant. A medical-grade silicone elastomer was used as implant material. Molds for µIM were 3D printed from a commercially available resin (TG = 84 °C) via a high-resolution DLP process (xy resolution of 32 µm, z resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bioefficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. The wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.

23 September 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
CWChunjiang Wei
Chunjiang Wei
Ziwen GaoZiwen Gao
Ziwen Gao
Robert MauRobert Mau
Robert Mau
TEThomas Eickner
Thomas Eickner
GJGabor Juettner
Gabor Juettner
Verena ScheperVerena Scheper
Verena Scheper
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (µCT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.

20 February 2023 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
FMFarnaz Matin
Farnaz Matin
Ziwen GaoZiwen Gao
Ziwen Gao
CWChunjiang Wei
Chunjiang Wei
FRFelix Repp
Felix Repp
EAEralp-Niyazi Artukarslan
Eralp-Niyazi Artukarslan
Verena ScheperVerena Scheper
Verena Scheper
The aim of this study was to develop and validate a semi-automated segmentation approach that identifies the round window niche (RWN) and round window membrane (RWM) for use in the development of patient individualized round window niche implants (RNI) to treat inner ear disorders. Twenty cone beam computed tomography (CBCT) datasets of unilateral temporal bones of patients were included in the study. Defined anatomical landmarks such as the RWM were used to develop a customized 3D Slicer™ plugin for semi-automated segmentation of the RWN. Two otolaryngologists (User 1 and User 2) segmented the datasets manually and semi-automatically using the developed software. Both methods were compared in-silico regarding the resulting RWM area and RWN volume. Finally, the developed software was validated ex-vivo in N = 3 body donor implantation tests with additively manufactured RNI. The independently segmented temporal bones of the different Users showed a strong consistency in the volume of the RWN and the area of the RWM. The volume of the semi-automated RWN segmentations were 48 ± 11% smaller on average than the manual segmentations and the area of the RWM of the semi-automated segmentations was 21 ± 17% smaller on average than the manual segmentation. All additively manufactured implants, based on the semi-automated segmentation method could be implanted successfully in a pressure-tight fit into the RWN. The implants based on the manual segmentations failed to fit into the RWN and this suggests that the larger manual segmentations were over-segmentations. This study presents a semi-automated approach for segmenting the RWN and RWM in temporal bone CBCT scans that is efficient, fast, accurate, and not dependent on trained users. In addition, the manual segmentation, often positioned as the gold-standard, actually failed to pass the implantation validation.

19 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Robert MauRobert Mau
Robert Mau
TEThomas Eickner
Thomas Eickner
GJGabor Juettner
Gabor Juettner
Ziwen GaoZiwen Gao
Ziwen Gao
CWChunjiang Wei
Chunjiang Wei
Hermann SeitzHermann Seitz
Hermann Seitz
A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm x 0.95 mm x 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). The medical grade silicone elastomer MED-4244 (NuSil Technology LLC, Radnor, PA, USA) was used. Molds for µIM were 3D printed from a commercially available resin PlasGRAY V2 (Asiga, Alexandria, Australia, TG = 84 °C) via a high-resolution DLP process (xy-resolution of 32 µm, z-resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bio-efficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. Wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over a time of 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over a time of 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.