The state-of-the-art modal identification for civil structures is limited to the estimation mode shapes with a low spatial resolution. Modal coordinates are identified only at the location of sensors, which are fixed at particular locations on the structure. Increasing the number of sensors in the structure is an alternative to increase the spatial resolution. Unfortunately, this increases the cost of the instrumentation and the data to be transmitted and processed. Another common alternative is to use numerical algorithms to expand the modal coordinates to nonmeasured degrees of freedom. However, mode shape expansion techniques could introduce errors in the identified modes. This paper presents the formulation, evaluation, and validation of a methodology for the ambient vibration–based modal identification using mobile sensors (MIMS). The methodology uses two sensors, one mobile and one stationary sensor, to identify spatially dense modes of vibration. The methodology is experimentally verified b...
The introduction of resistant and lightweight materials in the construction industry has led to civil structures being vulnerable to excessive vibrations, particularly in footbridges exposed to human-induced gait loads. This interaction, known as Human–Structure Interaction (HSI), involves a complex interplay between structural vibrations and gait loads. Despite extensive research on HSI, the simultaneous effects of lateral structural vibrations with fundamental frequencies close to human gait frequency (around 1.0 Hz) and wide amplitudes (over 30.0 mm) remain inadequately understood, posing a contemporary structural challenge highlighted by incidents in iconic bridges like the Millennium Bridge in London, Solferino Bridge in Paris, and Premier Bridge in Cali, Colombia. This paper focuses on the experimental exploration of Structure-to-Human Interaction (S2HI) effects using the Human–Structure Interaction Multi-Axial Test Framework (HSI-MTF). The framework enables the simultaneous measurement of vertical and lateral loads induced by human gait on surfaces with diverse frequency ranges and wide-amplitude lateral harmonic motions. The study involved seven test subjects, evaluating gait loads on rigid and harmonic lateral surfaces with displacements ranging from 5.0 to 50.0 mm and frequency content from 0.70 to 1.30 Hz. A low-cost vision-based motion capture system with smartphones analyzed the support (Tsu) and swing (Tsw) periods of human gait. Results indicated substantial differences in Tsu and Tsw on lateral harmonic protocols, reaching up to 96.53% and 58.15%, respectively, compared to rigid surfaces. Normalized lateral loads (LL) relative to the subject’s weight (W0) exhibited a linear growth proportional to lateral excitation frequency, with increased proportionality constants linked to higher vibration amplitudes. Linear regressions yielded an average R2 of 0.815. Regarding normalized vertical load (LV) with respect to W0, a consistent behavior was observed for amplitudes up to 30.0 mm, beyond which a linear increase, directly proportional to frequency, resulted in a 28.3% increment compared to rigid surfaces. Correlation analyses using Pearson linear coefficients determined relationships between structural surface vibration and pedestrian lateral motion, providing valuable insights into Structure-to-Human Interaction dynamics.
24 January 2024 in Structural Control and Health Monitoring
The dynamic performance of base isolation systems provides an effective means to reduce the seismic vulnerability of buildings. However, large displacements in the base isolation during seismic events pose a major challenge for this control system. Recently, novel control systems have been implemented to control and reduce the excessive displacements. This study presents an evaluation of the seismic performance of unconnected‐fiber‐reinforced elastomeric isolators (U‐FREI) and variable orifice damper (VOD) devices used together as a hybrid control system for a low‐degree‐of‐freedom reference structure by employing real‐time hybrid simulation (RTHS) testing technique. This physical cybernetic testing methodology allows a dynamic system of interest to be substructured into two components: numerical and experimental. In this study, the numerical substructure corresponds to a 2‐degree of freedom model, representing a reference structure, and an experimental substructure was formed using the hybrid control system described. To develop an interface between the two substructures, a horizontal transfer system (HTS) was implemented and coupled with a vertical transfer system (VTS). Using RTHS, the performance of the reference structure and the hybrid control system was evaluated under six seismic events: CAM, CAT, El Centro, Loma Prieta, Pizarro, and Chihuahua, at a maximum acceleration of 0.10 g (0.981 m·s−2). The experimental behavior of the hybrid control system allows the reference structure to reduce its maximum drift by more than 24% compared to the fixed structure. Finally, the performance and accuracy of the RTHS tests were calculated.
11 July 2019 in Structural Control and Health Monitoring