The dynamic performance of base isolation systems provides an effective means to reduce the seismic vulnerability of buildings. However, large displacements in the base isolation during seismic events pose a major challenge for this control system. Recently, novel control systems have been implemented to control and reduce the excessive displacements. This study presents an evaluation of the seismic performance of unconnected‐fiber‐reinforced elastomeric isolators (U‐FREI) and variable orifice damper (VOD) devices used together as a hybrid control system for a low‐degree‐of‐freedom reference structure by employing real‐time hybrid simulation (RTHS) testing technique. This physical cybernetic testing methodology allows a dynamic system of interest to be substructured into two components: numerical and experimental. In this study, the numerical substructure corresponds to a 2‐degree of freedom model, representing a reference structure, and an experimental substructure was formed using the hybrid control system described. To develop an interface between the two substructures, a horizontal transfer system (HTS) was implemented and coupled with a vertical transfer system (VTS). Using RTHS, the performance of the reference structure and the hybrid control system was evaluated under six seismic events: CAM, CAT, El Centro, Loma Prieta, Pizarro, and Chihuahua, at a maximum acceleration of 0.10 g (0.981 m·s−2). The experimental behavior of the hybrid control system allows the reference structure to reduce its maximum drift by more than 24% compared to the fixed structure. Finally, the performance and accuracy of the RTHS tests were calculated.
The dynamic performance of low-rise buildings under dynamic loads presents significant challenges in structural engineering. Accurate evaluation methods are crucial for ensuring the safety and resilience of these structures, especially in seismic-prone areas. This study focuses on implementing Real-Time Hybrid Simulations (RTHS) for the assessment of structural control systems in low-rise buildings. The research integrates a numerical substructure, which models the dynamic characteristics of the building, with an experimental substructure that consists of physical devices such as base isolators, semi-active fluid viscous dampers, or hybrid control system. The RTHS method provides a sophisticated platform to evaluate the effectiveness of hybrid control systems under seismic excitations. The results demonstrated a marked improvement in predicting structural responses, with the proposed method achieving a 15.0% reduction in error compared to fixed structure. Additionally, the application of hybrid control systems showed a 25.0% increase in energy dissipation capacity compared to individual passive control. These findings contribute to the advancement of resilient design strategies, offering a quantitative framework for optimizing structural control systems in low-rise buildings.