Hong Gee Roh

Prof. Dr. Hong Gee Roh


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2010 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
JHJin Ho Hwang
Jin Ho Hwang
HRHong Gee Roh
Hong Gee Roh
YCYoung Il Chun
Young Il Chun
HKHyun-Seung Kang
Hyun-Seung Kang
JCJIN WOO CHOI
JIN WOO CHOI
YKYoung Cho Koh
Young Cho Koh

1 January 2011 in Neurointervention
Verified
Journal Article
Open access
PDF file
JCJIN WOO CHOI
JIN WOO CHOI
HRHong Gee Roh
Hong Gee Roh
WMWon-Jin Moon
Won-Jin Moon
YCYoung Il Chun
Young Il Chun
CKChung Hwan Kang
Chung Hwan Kang
The in-stent signal reduction of the stented artery caused by susceptibility artifact or radiofrequency shielding artifact limited the use of time-of-flight MR angiography (TOF-MRA) as a follow-up tool after intracranial stenting. We showed the degree of an artifact according to different stent types, and optimized MR parameters for TOF-MRA in patients with intracranial stent on 3.0 T MRI. Four stents (Neuroform, Wingspan, Solitaire, and Enterprise) were placed in a vascular flow phantom and imaged by changing flip angle (FA; 20°,30°,40°,50° and 60°) and bandwidth (BW; 31, 42 and 62.5 KHz) using TOF-MRA. Source data of each image set with different FA and BW were reconstructed with the maximal intensity projection (MIP) technique, and MIP images were used to evaluate the in-stent signal reduction of each stent according to the change of MR parameters. The in-stent signal reduction was assessed by calculating the relative in-stent signal (RIS) inside the stent as compared with background and signal intensity of the tube outside the stent. The optimal FA and BW of each stent were determined by comparing the RIS in each stent by one-sample t test. Finally, one neuroradiologist chose one image set with the best image quality. The mean RIS for Neuroform, Wingspan, Solitaire and Enterprise stent was 66.3 ± 6.0, 44.2 ± 5.8, 22.8 ± 3.3 and 8.2 ± 2.9, respectively. The significantly high RIS of each stent was obtained with FA/BW value of 20°/31 KHz (Neuroform), 20°/31 KHz and 30°/42 KHz (Wingspan), 40°/42 KHz and 50°/31 KHz (Solitaire) and 40°/31 KHz and 50°/31 KHz (Enterprise). Among these MIP images with significantly high RIS, images with FA/BW value of 20°/31 KHz (Neuroform and Wingspan) and 50°/31 KHz (Solitaire and Enterprise) had the best image quality. The degree of artifact was variable according to the design of each intracranial stent. The luminal visualization of closed-cell design stents such as Solitaire and Enterprise can be improved by higher FA. Thus, MR parameter should be adjusted according to the type of intracranial stents.

1 January 2011 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JCJIN WOO CHOI
JIN WOO CHOI
HRHong Gee Roh
Hong Gee Roh
WMWon-Jin Moon
Won-Jin Moon
NKNa Ra Kim
Na Ra Kim
SMSung Gyu Moon
Sung Gyu Moon
HKHyun-Seung Kang
Hyun-Seung Kang
Choi JW, et al. Korean J Radiol. 2011 Nov-Dec;12(6):662-670. http://dx.doi.org/10.3348/kjr.2011.12.6.662

1 April 2020 in Radiology
Verified
Journal Article
Closed access
HKHyun Jeong Kim
Hyun Jeong Kim
SLSang Bong Lee
Sang Bong Lee
JCJIN WOO CHOI
JIN WOO CHOI
YJYoo Sung Jeon
Yoo Sung Jeon
HLHyung Jin Lee
Hyung Jin Lee
HRHong Gee Roh
Hong Gee Roh
An MR angiography collateral map provided patient-specific collateral perfusion information to help inform the prognosis and guide management of acute ischemic stroke through a minimal MRI protocol. Background Collateral circulation determines tissue fate and affects treatment result in acute ischemic stroke. A precise method for collateral estimation in an optimal imaging protocol is necessar...

1 January 2005 in Korean Journal of Radiology
Verified
Journal Article
Open access
YPYulri Park
Yulri Park
HRHong Gee Roh
Hong Gee Roh
SCSung Wook Choo
Sung Wook Choo
SLSung Hoon Lee
Sung Hoon Lee
SSSung Wook Shin
Sung Wook Shin
PJPyoung Jeon
Pyoung Jeon
Rapid and effective hemostasis at femoral puncture sites minimizes both the hospital stay and patient discomfort. Therefore, a variety of arterial closure devices have been developed to facilitate the closure of femoral arteriotomy. The objective of this prospective study was to compare the efficacy of two different closure devices; a collagen plug device (Angio-Seal) and a suture-mediated closure device (the Closer S). From March 28, 2003 to August 31, 2004, we conducted a prospective study in which 1,676 cases of 1,180 patients were treated with two different types of closure device. Angio-Seal was used in 961 cases and the Closer S in 715 cases. The efficacy of the closure devices was assessed, as well as complications occurring at the puncture sites. Successful immediate hemostasis was achieved in 95.2% of the cases treated with Angio-Seal, and in 89.5% of the cases treated with the Closer S (p < 0.05). The rates of minor and major complications occurring between the two groups were not significantly different. In the Closer S group, we observed four major complications (0.6%), that consisted of one massive retroperitoneal hemorrhage (surgically explored) and three pseudoaneurysms. In the Angio-Seal group, we observed three major complications (0.3%) that consisted of one femoral artery occlusion, one case of infection treated with intravenous antibiotics and one pseudoaneurysm. The use of Angio-Seal was found to be more effective than that of the Closer S with regard to the immediate hemostasis of the femoral puncture sites. However, we detected no significant differences in the rate at which complications occurred.

16 May 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HRHong Gee Roh
Hong Gee Roh
EKE.Y. Kim
E.Y. Kim
IKI.S. Kim
I.S. Kim
HLH.J. Lee
H.J. Lee
JPJeong Jin Park
Jeong Jin Park
HKH.J. Kim
H.J. Kim
BACKGROUND AND PURPOSE: Assessment of the collateral status has been emphasized for appropriate treatment decisions in patients with acute ischemic stroke. The purpose of this study was to introduce a multiphase MRA collateral imaging method (collateral map) derived from time-resolved dynamic contrast-enhanced MRA and to verify the value of the multiphase MRA collateral map in acute ischemic stroke by comparing it with the multiphase collateral imaging method (MRP collateral map) derived from dynamic susceptibility contrast-enhanced MR perfusion. MATERIALS AND METHODS: From a prospectively maintained registry of acute ischemic stroke, MR imaging data of patients with acute ischemic stroke caused by steno-occlusive lesions of the unilateral ICA and/or the M1 segment of the MCA were analyzed. We generated collateral maps using dynamic signals from dynamic contrast-enhanced MRA and DSC-MRP using a Matlab-based in-house program and graded the collateral scores of the multiphase MRA collateral map and the MRP collateral map independently. Interobserver reliabilities and intermethod agreement between both collateral maps for collateral grading were tested. RESULTS: Seventy-one paired multiphase MRA and MRP collateral maps from 67 patients were analyzed. The interobserver reliabilities for collateral grading using multiphase MRA or MRP collateral maps were excellent (weighted κ = 0.964 and 0.956, respectively). The agreement between both collateral maps was also excellent (weighted κ = 0.884; 95% confidence interval, 0.819–0.949). CONCLUSIONS: We demonstrated that the dynamic signals of dynamic contrast-enhanced MRA could be used to generate multiphase collateral images and showed the possibility of the multiphase MRA collateral map as a useful collateral imaging method in acute ischemic stroke.