InSeong Kim

InSeong Kim

Auto-generated profile, based on publicly available information

InSeong Kim

Siemens Healthineers Ltd., Seoul, Korea

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
HSH.S. Seo
H.S. Seo
EJE.-K. Jeong
E.-K. Jeong
SCSung Won Choi
Sung Won Choi
YKY. Kwon
Y. Kwon
HPH.-J. Park
H.-J. Park
IKI. Kim
I. Kim
BACKGROUND AND PURPOSE: Neurotransmitter changes in youth addicted to the Internet and smartphone were compared with normal controls and in subjects after cognitive behavioral therapy. In addition, the correlations between neurotransmitters and affective factors were investigated. MATERIALS AND METHODS: Nineteen young people with Internet and smartphone addiction and 19 sex- and age-matched healthy controls (male/female ratio, 9:10; mean age, 15.47 ± 3.06 years) were included. Twelve teenagers with Internet and smartphone addiction (male/female ratio, 8:4; mean age, 14.99 ± 1.95 years) participated in 9 weeks of cognitive behavioral therapy. Meshcher-Garwood point-resolved spectroscopy was used to measure γ-aminobutyric acid and Glx levels in the anterior cingulate cortex. The γ-aminobutyric acid and Glx levels in the addicted group were compared with those in controls and after cognitive behavioral therapy. The γ-aminobutyric acid and Glx levels correlated with clinical scales of Internet and smartphone addiction, impulsiveness, depression, anxiety, insomnia, and sleep quality. RESULTS: Brain parenchymal and gray matter volume–adjusted γ-aminobutyric acid-to-creatine ratios were higher in subjects with Internet and smartphone addiction (P = .028 and .016). After therapy, brain parenchymal- and gray matter volume–adjusted γ-aminobutyric acid-to-creatine ratios were decreased (P = .034 and .026). The Glx level was not statistically significant in subjects with Internet and smartphone addiction compared with controls and posttherapy status. Brain parenchymal- and gray matter volume–adjusted γ-aminobutyric acid-to-creatine ratios correlated with clinical scales of Internet and smartphone addictions, depression, and anxiety. Glx/Cr was negatively correlated with insomnia and sleep quality scales. CONCLUSIONS: The high γ-aminobutyric acid levels and disrupted balance of γ-aminobutyric acid-to-Glx including glutamate in the anterior cingulate cortex may contribute to understanding the pathophysiology and treatment of Internet and smartphone addiction and associated comorbidities.

1 April 2020 in Radiology
Verified
Journal Article
Closed access
HKHyun Jeong Kim
Hyun Jeong Kim
SLSang Bong Lee
Sang Bong Lee
JCJIN WOO CHOI
JIN WOO CHOI
YJYoo Sung Jeon
Yoo Sung Jeon
HLHyung Jin Lee
Hyung Jin Lee
HRHong Gee Roh
Hong Gee Roh
An MR angiography collateral map provided patient-specific collateral perfusion information to help inform the prognosis and guide management of acute ischemic stroke through a minimal MRI protocol. Background Collateral circulation determines tissue fate and affects treatment result in acute ischemic stroke. A precise method for collateral estimation in an optimal imaging protocol is necessar...

1 May 2024 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
JJJuhyun Jeong
Juhyun Jeong
SYSuk Keu Yeom
Suk Keu Yeom
ICIn Young Choi
In Young Choi
SCSang Hoon Cha
Sang Hoon Cha
JHJi Sung Han
Ji Sung Han
EWElisabeth Weiland
Elisabeth Weiland
Background: Image-based assessment of prostate cancer (PCa) is increasingly emphasized in the diagnostic workflow for selecting biopsy targets and possibly predicting clinically significant prostate cancer (csPCa). Assessment is based on Prostate Imaging-Reporting and Data System (PI-RADS) which is largely dependent on T2-weighted image (T2WI) and diffusion weighted image (DWI). This study aims to determine whether deep learning reconstruction (DLR) can improve the image quality of DWI and affect the assessment of PI-RADS ≥4 in patients with PCa. Methods: In this retrospective study, 3.0T post-biopsy prostate magnetic resonance imaging (MRI) of 70 patients with PCa in Korea University Ansan Hospital from November 2021 to July 2022 was reconstructed with and without using DLR. Four DWI image sets were made: (I) conventional DWI (CDWI): DWI with acceleration factor 2 and conventional parallel imaging reconstruction, (II) DL1: DWI with acceleration factor 2 using DLR, (III) DL2: DWI with acceleration factor 3 using DLR, and (IV) DL3: DWI with acceleration factor 3 and half average b-value using DLR. Apparent diffusion coefficient (ADC) value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured by one reviewer, while two reviewers independently assessed overall image quality, noise, and lesion conspicuity using a four-point visual scoring system from each DWI image set. Two reviewers also performed PI-RADSv2.1 scoring on lesions suspected of malignancy. Results: A total of 70 patients (mean age, 70.8±9.7 years) were analyzed. The image acquisition time was 4:46 min for CDWI and DL1, 3:40 min for DL2, and 2:00 min for DL3. DL1 and DL2 images resulted in better lesion conspicuity compared to CDWI images assessed by both readers (P<0.05). DLR resulted in a significant increase in SNR, from 38.4±14.7 in CDWI to 56.9±21.0 in DL1. CNR increased from 25.1±11.5 in CDWI to 43.1±17.8 in DL1 (P<0.001). PI-RADS v2.1 scoring for PCa lesions was more agreeable with the DL1 reconstruction method than with CDWI (κ value CDWI, DL1; 0.40, 0.61, respectively). A statistically significant number of lesions were upgraded from PI-RADS <4 in CDWI image to PI-RADS ≥4 in DL1 images for both readers (P<0.05). Most of the PI-RADS upgraded lesions were from higher than unfavorable intermediate-risk groups according to the 2023 National Comprehensive Cancer Network guidelines with statistically significant difference of marginal probability in DL1 and DL2 for both readers (P<0.05). Conclusions: DLR in DWI for PCa can provide options for improving image quality with a significant impact on PI-RADS evaluation or about a 23% reduction in acquisition time without compromising image quality.

16 May 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HRHong Gee Roh
Hong Gee Roh
EKE.Y. Kim
E.Y. Kim
IKI.S. Kim
I.S. Kim
HLH.J. Lee
H.J. Lee
JPJeong Jin Park
Jeong Jin Park
HKH.J. Kim
H.J. Kim
BACKGROUND AND PURPOSE: Assessment of the collateral status has been emphasized for appropriate treatment decisions in patients with acute ischemic stroke. The purpose of this study was to introduce a multiphase MRA collateral imaging method (collateral map) derived from time-resolved dynamic contrast-enhanced MRA and to verify the value of the multiphase MRA collateral map in acute ischemic stroke by comparing it with the multiphase collateral imaging method (MRP collateral map) derived from dynamic susceptibility contrast-enhanced MR perfusion. MATERIALS AND METHODS: From a prospectively maintained registry of acute ischemic stroke, MR imaging data of patients with acute ischemic stroke caused by steno-occlusive lesions of the unilateral ICA and/or the M1 segment of the MCA were analyzed. We generated collateral maps using dynamic signals from dynamic contrast-enhanced MRA and DSC-MRP using a Matlab-based in-house program and graded the collateral scores of the multiphase MRA collateral map and the MRP collateral map independently. Interobserver reliabilities and intermethod agreement between both collateral maps for collateral grading were tested. RESULTS: Seventy-one paired multiphase MRA and MRP collateral maps from 67 patients were analyzed. The interobserver reliabilities for collateral grading using multiphase MRA or MRP collateral maps were excellent (weighted κ = 0.964 and 0.956, respectively). The agreement between both collateral maps was also excellent (weighted κ = 0.884; 95% confidence interval, 0.819–0.949). CONCLUSIONS: We demonstrated that the dynamic signals of dynamic contrast-enhanced MRA could be used to generate multiphase collateral images and showed the possibility of the multiphase MRA collateral map as a useful collateral imaging method in acute ischemic stroke.

5 March 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
SHSeok Hahn
Seok Hahn
JSJi Soo Song
Ji Soo Song
ECEun Jung Choi
Eun Jung Choi
JCJang Gyu Cha
Jang Gyu Cha
YCYunjung Choi
Yunjung Choi
EPEun Hae Park
Eun Hae Park

25 March 2010 in IET Circuits, Devices & Systems
Verified
Journal Article
Closed access
HNHojung Nam
Hojung Nam
IKI. Kim
I. Kim
YAYoungho Ahn
Youngho Ahn
Jeongjin RohJeongjin Roh
Jeongjin Roh
A DC–DC switching converter chip is proposed to generate both positive and negative voltages for active-matrix LCD (AMLCD) bias. An inductive boost converter and two inverting charge pumps are integrated in a proposed chip by using a 0.5 µm 5 V, 3.5 µm 30 V CMOS process. A conventional scheme used to bias AMLCD employs a switching-boost converter with several off-chip components to generate the required positive and negative voltages. The circuit proposed in this study achieves high performance with a minimum number of off-chip components. Additionally, the proposed method is capable of generating a wide range of negative voltages by varying the reference voltage to supply optimised power for the AMLCD system. Because the supply voltage of the developed inverting charge pump is supplied by the output voltage of the boost converter through a linear regulator, the operations of switching-boost converter and inverting charge pump are independent and are without cross-regulation problems. The boost converter's input power supply range is 2.8–5.5 V, the output voltage range is 10–20 V and the clock frequency is 780 kHz. The maximum efficiency is 84% with the input power supply at 5.5 V, an output voltage of 10 V and a load current of 100 mA. The integrated inverting charge pumps have two outputs that generate −2× and −4× the reference voltage. The overall core size is 2150 µm×2150 µm.