Shaowei Jiang

Dr. Shaowei Jiang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2019 in Optics Express
Verified
Journal Article
Closed access
TZTeng Zhang
Teng Zhang
SJShaowei Jiang
Shaowei Jiang
ZZZixin Zhao
Zixin Zhao
KDKrishna Dixit
Krishna Dixit
XZXiaofei Zhou
Xiaofei Zhou
CYChenggang Yan
Chenggang Yan
Two-dimensional phase unwrapping algorithms are widely used in optical metrology and measurements. The high noise from interference measurements, however, often leads to the failure of conventional phase unwrapping algorithms. In this paper, we propose a deep convolutional neural network (DCNN) based method to perform rapid and robust two-dimensional phase unwrapping. In our approach, we employ a DCNN architecture, DeepLabV3+, with noise suppression and strong feature representation capabilities. The employed DCNN is first used to perform semantic segmentation to obtain the segmentation result of the wrapped phase map. We then combine the wrapped phase map with the segmentation result to generate the unwrapped phase. We benchmarked our results by comparing them with well-established methods. The reported approach out-performed the conventional path-dependent and path-independent algorithms. We also tested the robustness of the reported approach using interference measurements from optical metrology setups. Our results, again, clearly out-performed the conventional phase unwrap algorithms. The reported approach may find applications in optical metrology and microscopy imaging.

25 June 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
SJShaowei Jiang
Shaowei Jiang
KGKaikai Guo
Kaikai Guo
JLJun Liao
Jun Liao
GZGuoan Zheng
Guoan Zheng
Fourier ptychography is a recently developed imaging approach for large field-of-view and high-resolution microscopy. Here we model the Fourier ptychographic forward imaging process using a convolutional neural network (CNN) and recover the complex object information in a network training process. In this approach, the input of the network is the point spread function in the spatial domain or the coherent transfer function in the Fourier domain. The object is treated as 2D learnable weights of a convolutional or a multiplication layer. The output of the network is modeled as the loss function we aim to minimize. The batch size of the network corresponds to the number of captured low-resolution images in one forward/backward pass. We use a popular open-source machine learning library, TensorFlow, for setting up the network and conducting the optimization process. We analyze the performance of different learning rates, different solvers, and different batch sizes. It is shown that a large batch size with the Adam optimizer achieves the best performance in general. To accelerate the phase retrieval process, we also discuss a strategy to implement Fourier-magnitude projection using a multiplication neural network model. Since convolution and multiplication are the two most-common operations in imaging modeling, the reported approach may provide a new perspective to examine many coherent and incoherent systems. As a demonstration, we discuss the extensions of the reported networks for modeling single-pixel imaging and structured illumination microscopy (SIM). 4-frame resolution doubling is demonstrated using a neural network for SIM. The link between imaging systems and neural network modeling may enable the use of machine-learning hardware such as neural engine and tensor processing unit for accelerating the image reconstruction process. We have made our implementation code open-source for researchers.

11 February 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SJShaowei Jiang
Shaowei Jiang
JZJiakai Zhu
Jiakai Zhu
PSPengming Song
Pengming Song
CGChengfei Guo
Chengfei Guo
ZBZichao Bian
Zichao Bian
GZGuoan Zheng
Guoan Zheng
We report a novel lensless on-chip microscopy platform based on near-field blind ptychographic modulation. In this platform, we place a thin diffuser in between the object and the image sensor for light wave modulation. By blindly scanning the unknown diffuser to different x–y positions, we acquire a sequence of modulated intensity images for quantitative object recovery. Different from previous ptychographic implementations, we employ a unit magnification configuration with a Fresnel number of ∼50 000, which is orders of magnitude higher than those of previous ptychographic setups. The unit magnification configuration allows us to have the entire sensor area, 6.4 mm by 4.6 mm, as the imaging field of view. The ultra-high Fresnel number enables us to directly recover the positional shift of the diffuser in the phase retrieval process, addressing the positioning accuracy issue plaguing regular ptychographic experiments. In our implementation, we use a low-cost, DIY scanning stage to perform blind diffuser modulation. Precise mechanical scanning that is critical in conventional ptychography experiments is no longer needed in our setup. We further employ an up-sampling phase retrieval scheme to bypass the resolution limit set by the imager pixel size and demonstrate a half-pitch resolution of 0.78 μm. We validate the imaging performance via in vitro cell cultures, transparent and stained tissue sections, and a thick biological sample. We show that the recovered quantitative phase map can be used to perform effective cell segmentation of a dense yeast culture. We also demonstrate 3D digital refocusing of the thick biological sample based on the recovered wavefront. The reported platform provides a cost-effective and turnkey solution for large field-of-view, high-resolution, and quantitative on-chip microscopy. It is adaptable for a wide range of point-of-care-, global-health-, and telemedicine-related applications.

25 August 2020 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
ZBZichao Bian
Zichao Bian
CGChengfei Guo
Chengfei Guo
SJShaowei Jiang
Shaowei Jiang
JZJiakai Zhu
Jiakai Zhu
RWRuihai Wang
Ruihai Wang
GZGuoan Zheng
Guoan Zheng

8 March 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SJShaowei Jiang
Shaowei Jiang
JLJun Liao
Jun Liao
ZBZichao Bian
Zichao Bian
KGKaikai Guo
Kaikai Guo
YZYongbing Zhang
Yongbing Zhang
GZGuoan Zheng
Guoan Zheng
A whole slide imaging (WSI) system has recently been approved for primary diagnostic use in the US. The image quality and system throughput of WSI is largely determined by the autofocusing process. Traditional approaches acquire multiple images along the optical axis and maximize a figure of merit for autofocusing. Here we explore the use of deep convolution neural networks (CNNs) to predict the focal position of the acquired image without axial scanning. We investigate the autofocusing performance with three illumination settings: incoherent Kohler illumination, partially coherent illumination with two plane waves, and one-plane-wave illumination. We acquire ~130,000 images with different defocus distances as the training data set. Different defocus distances lead to different spatial features of the captured images. However, solely relying on the spatial information leads to a relatively bad performance of the autofocusing process. It is better to extract defocus features from transform domains of the acquired image. For incoherent illumination, the Fourier cutoff frequency is directly related to the defocus distance. Similarly, autocorrelation peaks are directly related to the defocus distance for two-plane-wave illumination. In our implementation, we use the spatial image, the Fourier spectrum, the autocorrelation of the spatial image, and combinations thereof as the inputs for the CNNs. We show that the information from the transform domains can improve the performance and robustness of the autofocusing process. The resulting focusing error is ~0.5 µm, which is within the 0.8-µm depth-of-field range. The reported approach requires little hardware modification for conventional WSI systems and the images can be captured on the fly without focus map surveying. It may find applications in WSI and time-lapse microscopy. The transform- and multi-domain approaches may also provide new insights for developing microscopy-related deep-learning networks. We have made our training and testing data set (~12 GB) open-source for the broad research community.

27 February 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
HZHe Zhang
He Zhang
SJShaowei Jiang
Shaowei Jiang
JLJun Liao
Jun Liao
JDJunjing Deng
Junjing Deng
JLJian Liu
Jian Liu
GZGuoan Zheng
Guoan Zheng
High spatial resolution is the goal of many imaging systems. While designing a high-resolution lens with diffraction-limited performance over a large field of view remains a difficult task, creating a complex speckle pattern with wavelength-limited spatial features is easily accomplished with a simple random diffuser. With this observation and the concept of near-field ptychography, we report a new imaging modality, termed near-field Fourier ptychography, to address high-resolution imaging challenges in both microscopic and macroscopic imaging settings. ‘Near-field’ refers to placing the object at a short defocus distance with a large Fresnel number. We project a speckle pattern with fine spatial features on the object instead of directly resolving the spatial features via a high-resolution lens. We then translate the object (or speckle) to different positions and acquire the corresponding images by using a low-resolution lens. A ptychographic phase retrieval process is used to recover the complex object, the unknown speckle pattern, and the coherent transfer function at the same time. In a microscopic imaging setup, we use a 0.12 numerical aperture (NA) lens to achieve an NA of 0.85 in the reconstruction process. In a macroscale photographic imaging setup, we achieve ~7-fold resolution gain by using a photographic lens. The collection optics do not determine the final achievable resolution; rather, the speckle pattern’s feature size does. This is similar to our recent demonstration in fluorescence imaging settings (Guo et al., Biomed. Opt. Express, 9(1), 2018). The reported imaging modality can be employed in light, coherent X-ray, and transmission electron imaging systems to increase resolution and provide quantitative absorption and object phase contrast.