Zichao Bian

Zichao Bian

Auto-generated profile, based on publicly available information

Zichao Bian

University of Connecticut

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
SDSiyuan Dong
Siyuan Dong
RHRoarke Horstmeyer
Roarke Horstmeyer
RSRadhika Shiradkar
Radhika Shiradkar
KGKaikai Guo
Kaikai Guo
XOXiaoze Ou
Xiaoze Ou
GZGuoan Zheng
Guoan Zheng
We report an imaging scheme, termed aperture-scanning Fourier ptychography, for 3D refocusing and super-resolution macroscopic imaging. The reported scheme scans an aperture at the Fourier plane of an optical system and acquires the corresponding intensity images of the object. The acquired images are then synthesized in the frequency domain to recover a high-resolution complex sample wavefront; no phase information is needed in the recovery process. We demonstrate two applications of the reported scheme. In the first example, we use an aperture-scanning Fourier ptychography platform to recover the complex hologram of extended objects. The recovered hologram is then digitally propagated into different planes along the optical axis to examine the 3D structure of the object. We also demonstrate a reconstruction resolution better than the detector pixel limit (i.e., pixel super-resolution). In the second example, we develop a camera-scanning Fourier ptychography platform for super-resolution macroscopic imaging. By simply scanning the camera over different positions, we bypass the diffraction limit of the photographic lens and recover a super-resolution image of an object placed at the far field. This platform’s maximum achievable resolution is ultimately determined by the camera’s traveling range, not the aperture size of the lens. The FP scheme reported in this work may find applications in 3D object tracking, synthetic aperture imaging, remote sensing, and optical/electron/X-ray microscopy.

8 March 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SJShaowei Jiang
Shaowei Jiang
JLJun Liao
Jun Liao
ZBZichao Bian
Zichao Bian
KGKaikai Guo
Kaikai Guo
YZYongbing Zhang
Yongbing Zhang
GZGuoan Zheng
Guoan Zheng
A whole slide imaging (WSI) system has recently been approved for primary diagnostic use in the US. The image quality and system throughput of WSI is largely determined by the autofocusing process. Traditional approaches acquire multiple images along the optical axis and maximize a figure of merit for autofocusing. Here we explore the use of deep convolution neural networks (CNNs) to predict the focal position of the acquired image without axial scanning. We investigate the autofocusing performance with three illumination settings: incoherent Kohler illumination, partially coherent illumination with two plane waves, and one-plane-wave illumination. We acquire ~130,000 images with different defocus distances as the training data set. Different defocus distances lead to different spatial features of the captured images. However, solely relying on the spatial information leads to a relatively bad performance of the autofocusing process. It is better to extract defocus features from transform domains of the acquired image. For incoherent illumination, the Fourier cutoff frequency is directly related to the defocus distance. Similarly, autocorrelation peaks are directly related to the defocus distance for two-plane-wave illumination. In our implementation, we use the spatial image, the Fourier spectrum, the autocorrelation of the spatial image, and combinations thereof as the inputs for the CNNs. We show that the information from the transform domains can improve the performance and robustness of the autofocusing process. The resulting focusing error is ~0.5 µm, which is within the 0.8-µm depth-of-field range. The reported approach requires little hardware modification for conventional WSI systems and the images can be captured on the fly without focus map surveying. It may find applications in WSI and time-lapse microscopy. The transform- and multi-domain approaches may also provide new insights for developing microscopy-related deep-learning networks. We have made our training and testing data set (~12 GB) open-source for the broad research community.

22 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DJDevina Jaiswal
Devina Jaiswal
NCNorah Cowley
Norah Cowley
ZBZichao Bian
Zichao Bian
GZGuoan Zheng
Guoan Zheng
KCKevin P. Claffey
Kevin P. Claffey
KHKazunori Hoshino
Kazunori Hoshino
We describe a novel mechanical characterization method that has directly measured the stiffness of cancer spheroids for the first time to our knowledge. Stiffness is known to be a key parameter that characterizes cancerous and normal cells. Atomic force microscopy or optical tweezers have been typically used for characterization of single cells with the measurable forces ranging from sub pN to a few hundred nN, which are not suitable for measurement of larger 3D cellular structures such as spheroids, whose mechanical characteristics have not been fully studied. Here, we developed microtweezers that measure forces from sub hundred nN to mN. The wide force range was achieved by the use of replaceable cantilevers fabricated from SU8, and brass. The chopstick-like motion of the two cantilevers facilitates easy handling of samples and microscopic observation for mechanical characterization. The cantilever bending was optically tracked to find the applied force and sample stiffness. The efficacy of the method was demonstrated through stiffness measurement of agarose pillars with known concentrations. Following the initial system evaluation with agarose, two cancerous (T47D and BT474) and one normal epithelial (MCF 10A) breast cell lines were used to conduct multi-cellular spheroid measurements to find Young’s moduli of 230, 420 and 1250 Pa for BT474, T47D, and MCF 10A, respectively. The results showed that BT474 and T47D spheroids are six and three times softer than epithelial MCF10A spheroids, respectively. Our method successfully characterized samples with wide range of Young’s modulus including agarose (25–100 kPa), spheroids of cancerous and non-malignant cells (190–200 μm, 230–1250 Pa) and collagenase-treated spheroids (215 μm, 130 Pa).

24 December 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
CGChengfei Guo
Chengfei Guo
ZBZichao Bian
Zichao Bian
SJShaowei Jiang
Shaowei Jiang
MMMichael Murphy
Michael Murphy
JZJiakai Zhu
Jiakai Zhu
GZGuoan Zheng
Guoan Zheng
Recent advancements in whole slide imaging (WSI) have moved pathology closer to digital practice. Existing systems require precise mechanical control, and the cost is prohibitive for most individual pathologists. Here we report a low-cost and high-throughput WSI system termed OpenWSI. The reported system is built using off-the-shelf components, including a programmable LED array, a photographic lens, and a low-cost computer numerical control (CNC) router. Different from conventional WSI platforms, our system performs real-time single-frame autofocusing using color-multiplexed illumination. For axial positioning control, we perform coarse adjustment using the CNC router and precise adjustment using the ultrasonic motor ring in the photographic lens. By using a 20X objective lens, we show that the OpenWSI system has a resolution of ∼ 0.7 µ m . It can acquire whole slide images of a 225 m m 2 region in ∼ 2 m i n s with throughput comparable to existing high-end platforms. The reported system offers a turnkey solution to transform the high-end WSI platforms into one that can be made broadly available and utilizable without loss of capacity.

4 August 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
KGKaikai Guo
Kaikai Guo
JLJun Liao
Jun Liao
ZBZichao Bian
Zichao Bian
XHXin Heng
Xin Heng
GZGuoan Zheng
Guoan Zheng
We report the development of a high-throughput whole slide imaging (WSI) system by adapting a cost-effective optomechanical add-on kit to existing microscopes. Inspired by the phase detection concept in professional photography, we attached two pinhole-modulated cameras at the eyepiece ports for instant focal plane detection. By adjusting the positions of the pinholes, we can effectively change the view angle for the sample, and as such, we can use the translation shift of the two pinhole-modulated images to identify the optimal focal position. By using a small pinhole size, the focal-plane-detection range is on the order of millimeter, orders of magnitude longer than the objective’s depth of field. We also show that, by analyzing the phase correlation of the pinhole-modulated images, we can determine whether the sample contains one thin section, folded sections, or multiple layers separated by certain distances – an important piece of information prior to a detailed z scan. In order to achieve system automation, we deployed a low-cost programmable robotic arm to perform sample loading and $14 stepper motors to drive the microscope stage to perform x-y scanning. Using a 20X objective lens, we can acquire a 2 gigapixel image with 14 mm by 8 mm field of view in 90 seconds. The reported platform may find applications in biomedical research, telemedicine, and digital pathology. It may also provide new insights for the development of high-content screening instruments.

18 July 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
PSPengming Song
Pengming Song
SJShaowei Jiang
Shaowei Jiang
HZHe Zhang
He Zhang
ZBZichao Bian
Zichao Bian
CGChengfei Guo
Chengfei Guo
GZGuoan Zheng
Guoan Zheng
We report a new coherent imaging technique, termed ptychographic structured modulation (PSM), for quantitative super-resolution microscopy. In this technique, we place a thin diffuser (i.e., a scattering lens) in between the sample and the objective lens to modulate the complex light waves from the object. The otherwise inaccessible high-resolution object information can thus be encoded into the captured images. We then employ a ptychographic phase retrieval process to jointly recover the exit wavefront of the complex object and the unknown diffuser profile. Unlike the illumination-based super-resolution approach, the recovered image of our approach depends upon how the complex wavefront exits the sample—not enters it. Therefore, the sample thickness becomes irrelevant during reconstruction. After recovery, we can propagate the super-resolution complex wavefront to any position along the optical axis. We validate our approach using a resolution target, a quantitative phase target, a two-layer sample, and a thick polydimethylsiloxane sample. We demonstrate a 4.5-fold resolution gain over the diffraction limit. We also show that a four-fold resolution gain can be achieved with as few as ∼30 images. The reported approach may provide a quantitative super-resolution strategy for coherent light, x-ray, and electron imaging.