Laura Barberán Bernardos

Ms. Laura Barberán Bernardos

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Journal of Ophthalmology
Verified
Journal Article
Open access
LBLaura Barberán Bernardos
Laura Barberán Bernardos
NJNatalia Jiménez
Natalia Jiménez
David P PiñeroDavid P Piñero
David P Piñero
Objective. To investigate if the use of vision therapy (VT) in convergence insufficiency (CI) has a significant neural impact and how it correlates with the clinical changes occurring with this option of treatment. Methods. A systematic review of the scientific literature was carried out in the PubMed and Scopus databases, where all the scientific literature on the neural impact of VT in CI was analyzed. A total of 17 articles were initially found and a detailed analysis was carried out. After full‐text reading, only four studies met the defined inclusion criteria. The following data from them were extracted: CI cases and controls, clinical and neural parameters evaluated, the neural response to VT observed, type of study, and VT performed. The quality of the studies was assessed using the GRADE tool. Results. Some neural changes have been reported after VT in CI with the use of functional magnetic resonance imaging (fMRI). Specifically, a modification of the functional activity of some brain areas (especially front fields, oculomotor vermis, and cerebellum) was found. However, contradictory findings in terms of the change in functional activity (increase or decrease) were found that might be associated to differences in fMRI protocols. In the GRADE analysis, serious concerns were found in the categories of risk of bias, inconsistency, indirectness, and imprecision, so the certainty of evidence for each outcome was very low. Conclusion. The research performed to this date does not allow confirming if there are neural changes occurring after vision therapy in patients with CI because the quality of the research performed on this issue is very low, with several methodological concerns.

12 October 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
EMElena Martínez-Plaza
Elena Martínez-Plaza
LBLaura Barberán Bernardos
Laura Barberán Bernardos
AMAinhoa Molina-Martín
Ainhoa Molina-Martín
David P PiñeroDavid P Piñero
David P Piñero
Objective: To evaluate the accuracy of diagnosing dry eye disease (DED) by using the Visionix VX120+, to establish reference values for tear meniscus height (TMH) and non-invasive break-up time (NIBUT), and to compare the NIBUT measurements with the fluorescein tear break-up time (FBUT), Methods: fifty-eight subjects (34 dry eye and 24 control) were enrolled. The TMH, first NIBUT, and NIBUT50% were evaluated with the Visionix VX120+, and the FBUT was measured with a slit-lamp. The Receiver Operating Characteristic (ROC) curve was used to evaluate the diagnostic performance, and the Bland–Altman method was performed to analyze the agreement. Results: The areas under the curve were 0.62, 0.60, and 0.70 for the TMH, first NIBUT, and NIBUT50%, respectively. The optimal cut-off values (sensitivity, specificity) were 0.29 (0.62, 0.67), 5.05 (0.85, 0.46), and 7.35 (0.65, 0.79) for the TMH, first NIBUT, and NIBUT50%, respectively. The mean differences (lower, upper limits of agreement) were −1.10 (−8.78, 6.58) and 1.55 (−5.68, 8.78) for the first NIBUT vs. FBUT and the NIBUT50% vs. FBUT, respectively. Conclusions: In conclusion, the NIBUT50% can be a useful tool for dry eye screening, with acceptable values of sensitivity and specificity. First, the NIBUT and NIBUT50% should not be used interchangeably with the FBUT.

24 November 2025 in Journal of Optometry
Verified
Journal Article
Open access
LBLaura Barberán Bernardos
Laura Barberán Bernardos
MAMiguel Ángel Ariza-Gracia
Miguel Ángel Ariza-Gracia
David P PiñeroDavid P Piñero
David P Piñero
To characterize diurnal variations in scleral morphological parameters and assess correlations between lifestyle habits and variations in these parameters. This prospective observational study enrolled healthy adult participants. Corneo-scleral morphology was evaluated at five standardized timepoints (9:00, 11:30, 14:00, 16:30, and 19:00) using the Pentacam HR corneo-scleral profile module. Participants completed a lifestyle questionnaire assessing sleep patterns and daily routines. Primary outcome measures included sagittal height (SH) and bulbar slope (BS), with coefficients of variation (CV) across the day calculated for each parameter. A total of 109 eyes from 55 participants (mean age: 32.6 ± 12.6 years; 37 female, 18 male) were analyzed. Repeated-measures analysis revealed no statistically significant diurnal variations in scleral parameters (all p-values ≥ 0.069). Secondary analysis identified some significant correlations between CVs of scleral parameters and specific lifestyle habits: washing face in the morning (minimum BS, p=0.007), having breakfast (minimum SH, p≤0.016), drinking coffee in the morning (SH p≤0.040), drinking coffee during the day (mean SH p=0.016), and screen exposure before bedtime (mean SH p=0.036). Statistically significant sex-related differences were observed in minimum BS of the right eye (p=0.020) and astigmatic SH (p=0.042). The corneo-scleral profile of healthy eyes remains stable throughout the day, with no significant diurnal changes in SH or BS. Although certain lifestyle habits showed trends toward association with scleral variation, definitive conclusions cannot be drawn.

4 July 2024 in Clinical and Experimental Optometry
Verified
Journal Article
Closed access
DPDavid P Piñero
David P Piñero
LBLaura Barberán Bernardos
Laura Barberán Bernardos
EMElena Martínez-Plaza
Elena Martínez-Plaza
AMAinhoa Molina-Martín
Ainhoa Molina-Martín
LBLaurent Bataille
Laurent Bataille
Perception of optometrists and ophthalmologists of vision therapy (VT) as well as their methods for performing the sessions is of great importance for understanding the problems that professionals face and what should be improved in their clinical practice. The objective of this study was to determine the perception of VT and protocols used by eye care professionals globally. A cross-sectional study was performed among eye care professionals internationally. The participants completed via online (Google Forms) a questionnaire of 40 questions on their perception and clinical practice of VT. The survey only permitted one answer per email address and was only collected if professionals gave their consent to participate. A total of 205 professionals from 43 countries answered the questionnaire (171 optometrists and 34 ophthalmologists). Accommodation and convergence problems were the main indication reported for VT (47.8%), followed by amblyopia (26.3%). The principal negative factor associated to VT was the limited number of professionals dedicated to this field (55.6%). The most common program of VT was the combination of VT sessions at home and at office (85.5%), with a great variability in terms of duration. Few professionals made use of the new technologies when programming VT, such as eye trackers (2.7%) or virtual reality (6.4%). European professionals surveyed had a more negative perception of VT (p < 0.031). Eye care professionals globally perceive VT as a scientifically based procedure. Overall, they believe that it has low recognition and prestige, especially ophthalmologists. A great variability in the programming of VT sessions was found, which highlights the need for standardised protocols that professionals could follow in their clinical practice.

22 April 2026 in Life
Verified
Journal Article
Open access
PDF file
LBLaura Barberán Bernardos
Laura Barberán Bernardos
Miguel Angel Ariza-GraciaMiguel Angel Ariza-Gracia
Miguel Angel Ariza-Gracia
PBPhilippe Büchler
Philippe Büchler
David P PiñeroDavid P Piñero
David P Piñero
This study aims to characterize diurnal changes in corneal geometry of the anterior and posterior cornea in healthy eyes using global and sector-based metrics, and to explore their associations with lifestyle-related factors. A prospective observational study of 109 eyes was conducted, measuring intraocular pressure (IOP), corneal thickness, volume, and global/sector-based keratometry at five time points over a 10 h period, alongside a lifestyle questionnaire. Results revealed significant diurnal decreases in IOP, central and minimum corneal thickness, and corneal volume (p ≤ 0.031). While posterior keratometry remained stable, anterior keratometry showed statistically significant but clinically negligible changes (amplitude of change ≤ 0.29 D), primarily within the central 4 mm and inferotemporal regions. Weak to moderate positive correlations were found between water and coffee intake, smoking, and changes in corneal thickness and volume, with no relevant effects on keratometric parameters. Overall, corneal thickness and volume exhibit significant diurnal reductions, whereas anterior keratometric changes are minimal and clinically irrelevant globally. These findings underscore the importance of considering the time of day when interpreting corneal measurements, as lifestyle factors appear to modulate corneal thickness but not curvature in healthy eyes.

27 July 2026 in Vision
Verified
Journal Article
Open access
PDF file
LBLaura Barberán Bernardos
Laura Barberán Bernardos
Miguel Angel Ariza-GraciaMiguel Angel Ariza-Gracia
Miguel Angel Ariza-Gracia
David P PiñeroDavid P Piñero
David P Piñero
Despite the widespread use of orthokeratology (ortho-k), the diurnal behavior of corneal geometry after lens removal remains unclear. This prospective observational study evaluated diurnal variations in corneal geometry, refractive error, and visual performance in ortho-k wearers using global and sector-based corneal analyses. Nineteen eyes from ten ortho-k wearers were examined at five time points over a 10-h period following overnight lens wear. Corneal thickness, anterior and posterior corneal curvature, corneal asphericity, autorefractometry, and visual acuity were assessed. Corneal elevation data were reconstructed using Zernike polynomial expansions, and regional analyses were performed using concentric annular sectors. Diurnal amplitudes were compared with a healthy control cohort evaluated using the same protocol. Corneal thickness progressively decreased throughout the day (p < 0.001). Anterior corneal curvature showed progressive steepening (p ≤ 0.011), whereas posterior corneal curvature exhibited significant flattening (p ≤ 0.018). A progressive myopic refractive shift was also observed, with a spherical equivalent amplitude of −1.03 D (p = 0.002). Despite these changes, visual acuity remained stable (p = 0.248). Compared with healthy controls, ortho-k wearers showed greater amplitudes of central corneal thickness and anterior corneal curvature changes. These findings indicate that ortho-k may enhance normal diurnal corneal changes while maintaining visual acuity.