An ultrafast response metal–semiconductor–metal type ZnO ultraviolet photodetector was fabricated by ultraviolet nanoimprint lithography (UV-NIL) with hydrothermal synthesis. The extremely fast response time was due to the Schottky barrier formation attributed to the control of the hydrothermal growth time and grating structure of ZnO, produced by a position-controlled pattering method of UV-NIL. With an on/off frequency of ultraviolet light of 2 kHz using an optical chopper, the device exhibits a rising time of 43 μs and a falling time of 54 μs at a low bias voltage (0.5 V) with a responsivity of 22.1 A W−1 in the active area of 5 × 5 μm2. In comparison to other fast response ZnO photodetectors, our device definitely uses easy and low-cost fabrication methods as well as exhibits high performance.
A graphene-PbS quantum dot (QD) composite for application in high-performance near-infrared (NIR) photodetectors (PDs) is proposed in this study. A single-layer graphene flake and oleic acid-capped PbS QD composite is fabricated through the conventional sonication process, in hexane solution. Field emission scanning electron microscopy images of the graphene-PbS QD composite dispersed on a glass substrate confirm that the composite contains both aggregated graphene flakes and single-layer graphene with wrinkles; Transmission electron microscopy images reveal close packing with uniform size. The increased absorbance and quenched photoluminescence intensity of the graphene-PbS QD composite supports enhanced photoinduced charge transfer between graphene and the PbS QDs. Moreover, the specific Raman mode of the PbS QDs, embedded in the spectrum, is enhanced by combination with graphene, which can be interpreted by SERS as relevant to the photoinduced charge transfer between the Pbs QDs and graphene. For device application, a PD structure comprised by graphene-PbS QDs is fabricated. The photocurrent of the PD is measured using a conventional probe station with a 980-nm NIR laser diode. In the fabricated PD comprising graphene-PbS QDs, five-times higher photocurrent, 22% faster rise time, and 47% faster decay time are observed, compared to that comprising PbS QDs alone. This establishes the potential of the graphene-PbS QD composite for application in ultrathin, flexible, high-performance NIR PDs.
9 July 2015 in The Journal of Physical Chemistry C
Background: The size of nanoparticles is considered to influence their toxicity, as smaller-sized nanoparticles should more easily penetrate the cell and exert toxic effects. However, conflicting results and unstandardized methodology have resulted in controversy of these size-dependent effects. Here, we introduce a unique approach to study such size-dependent effects of nanoparticles and present evidence that reliably supports this general assumption along with elucidation of the underlying cytotoxic mechanism. Methods: We prepared and physically characterized size-controlled (20–50 nm) monodispersed silica nanoparticles (SNPs) in aqueous suspensions. Then, a variety of biochemical assessments are used for evaluating the cytotoxic mechanisms. Results: SNP treatment in three cell lines decreased cell viability and migration ability, while ROS production increased in dose- and size-dependent manners, with SNPs <30 nm showing the greatest effects. 30- and 40-nm SNPs were observed similar to these biological activities of 20- and 50-nm, respectively. Under the conventionally used serum-free conditions, both 20-nm and 50-nm SNPs at the IC50 values (75.2 and 175.2 μg/mL) induced apoptosis and necrosis in HepG2 cells, whereas necrosis was more rapid with the smaller SNPs. Inhibiting endocytosis impeded the internalization of the 50-nm but not the 20-nm SNPs. However, agglomeration following serum exposure increased the size of the 20-nm SNPs to approximately 50 nm, preventing their internalization and cell membrane damage without necrosis. Thus, 20-nm and 50-nm SNPs show different modes of cellular uptake, with smaller SNPs capable of trafficking into the cells in an endocytosis-independent manner. This approach of using non-overlapping size classes of SNPs under the same dose, along with serum-induced agglomeration analysis clarifies this long-standing question about the safety of small SNPs. Conclusion: Our results highlight the need to revise safety guidelines to account for this demonstrated size-dependent cytotoxicity under serum-free conditions, which may be similar to the microenvironment after tissue penetration.
This study investigates the effect of focal plane variation using vibration in a femtosecond laser hole drilling process on Invar alloy fabrication quality for the production of fine metal masks (FMMs). FMMs are used in the red, green, blue (RGB) evaporation process in Active Matrix Organic Light-Emitting Diode (AMOLED) manufacturing. The taper angle of the hole is adjusted by attaching the objective lens to a micro-vibrator and continuously changing the focal plane position. Eight laser pulses were used to examine how the hole characteristics vary with the first focal plane’s position, where the first pulse is focused at an initial position and the focal planes of subsequent pulses move downward. The results showed that the hole taper angle can be controlled by varying the amplitude of the continuously operating vibrator during femtosecond laser hole machining. The taper angles were changed between 31.8° and 43.9° by adjusting the vibrator amplitude at a frequency of 100 Hz. Femtosecond laser hole drilling with controllable taper angles is expected to be used in the precision micro-machining of various smart devices.