Max Ortiz-Catalan

Prof. Dr. Max Ortiz-Catalan

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2014 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
BHBo Håkansson
Bo Håkansson
RBRickard Brånemark
Rickard Brånemark
An osseointegrated interface allowed long-term stable and bidirectional communication between robotic prostheses and implanted neuromuscular electrodes for intuitive control with sensory feedback in one patient.

1 December 2016 in The Lancet
Verified
Journal Article
Closed access
MOMax Ortiz-Catalan
Max Ortiz-Catalan
RGRannveig A Guðmundsdóttir
Rannveig A Guðmundsdóttir
MKMorten Bak Kristoffersen
Morten Bak Kristoffersen
AZAlejandra Zepeda-Echavarria
Alejandra Zepeda-Echavarria
KCKerstin Caine-Winterberger
Kerstin Caine-Winterberger
LHLiselotte Hermansson
Liselotte Hermansson

30 April 2020 in New England Journal of Medicine
Verified
Journal Article
Closed access
MOMax Ortiz-Catalan
Max Ortiz-Catalan
EMEnzo Mastinu
Enzo Mastinu
PSPaolo Sassu
Paolo Sassu
OAOskar Aszmann
Oskar Aszmann
RBRickard Brånemark
Rickard Brånemark
We report the use of a bone-anchored, self-contained robotic arm with both sensory and motor components over 3 to 7 years in four patients after transhumeral amputation. The implant allowed for bidirectional communication between a prosthetic hand and electrodes implanted in the nerves and muscles of the upper arm and was anchored to the humerus through osseointegration, the process in which bone cells attach to an artificial surface without formation of fibrous tissue. Use of the device did not require formal training and depended on the intuitive intent of the user to activate movement and sensory feedback from the prosthesis. Daily use resulted in increasing sensory acuity and effectiveness in work and other activities of daily life. (Funded by the Promobilia Foundation and others.)

18 April 2013 in Source Code for Biology and Medicine
Verified
Journal Article
Open access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
RBRickard Brånemark
Rickard Brånemark
BHBo Håkansson
Bo Håkansson
Processing and pattern recognition of myoelectric signals have been at the core of prosthetic control research in the last decade. Although most studies agree on reporting the accuracy of predicting predefined movements, there is a significant amount of study-dependent variables that make high-resolution inter-study comparison practically impossible. As an effort to provide a common research platform for the development and evaluation of algorithms in prosthetic control, we introduce BioPatRec as open source software. BioPatRec allows a seamless implementation of a variety of algorithms in the fields of (1) Signal processing; (2) Feature selection and extraction; (3) Pattern recognition; and, (4) Real-time control. Furthermore, since the platform is highly modular and customizable, researchers from different fields can seamlessly benchmark their algorithms by applying them in prosthetic control, without necessarily knowing how to obtain and process bioelectric signals, or how to produce and evaluate physically meaningful outputs.

18 January 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
CGClara Günter
Clara Günter
JDJean Delbeke
Jean Delbeke
MOMax Ortiz-Catalan
Max Ortiz-Catalan
Electrical stimulation of peripheral nerves is used in a variety of applications such as restoring motor function in paralyzed limbs, and more recently, as means to provide intuitive sensory feedback in limb prostheses. However, literature on the safety requirements for stimulation is scarce, particularly for chronic applications. Some aspects of nerve interfacing such as the effect of stimulation parameters on electrochemical processes and charge limitations have been reviewed, but often only for applications in the central nervous system. This review focuses on the safety of electrical stimulation of peripheral nerve in humans. We analyzed early animal studies evaluating damage thresholds, as well as more recent investigations in humans. Safety requirements were divided into two main categories: passive and active safety. We made the distinction between short-term (< 30 days) and chronic (> 30 days) applications, as well as between electrode preservation (biostability) and body tissue healthy survival (harmlessness). In addition, transferability of experimental results between different tissues and species was considered. At present, extraneural electrodes have shown superior long-term stability in comparison to intraneural electrodes. Safety limitations on pulse amplitude (and consequently, charge injection) are dependent on geometrical factors such as electrode placement, size, and proximity to the stimulated fiber. In contrast, other parameters such as stimulation frequency and percentage of effective stimulation time are more generally applicable. Currently, chronic stimulation at frequencies below 30 Hz and percentages of effective stimulation time below 50% is considered safe, but more precise data drawn from large databases are necessary. Unfortunately, stimulation protocols are not systematically documented in the literature, which limits the feasibility of meta-analysis and impedes the generalization of conclusions. We therefore propose a standardized list of parameters necessary to define electrical stimulation and allow future studies to contribute to meta-analyses. The safety of chronic continuous peripheral nerve stimulation at frequencies higher than 30 Hz has yet to be documented. Precise parameter values leading to stimulation-induced depression of neuronal excitability (SIDNE) and neuronal damage, as well as the transition between the two, are still lacking. At present, neural damage mechanisms through electrical stimulation remain obscure.

1 January 2014 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
NSNichlas Sander
Nichlas Sander
MKMorten Bak Kristoffersen
Morten Bak Kristoffersen
BHBo Håkansson
Bo Håkansson
RBRickard Brånemark
Rickard Brånemark
A variety of treatments have been historically used to alleviate phantom limb pain (PLP) with varying efficacy. Recently, virtual reality (VR) has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR). Further, phantom motions are facilitated and encouraged through gaming.The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy) for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game.The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives.Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study.