Bo Håkansson

Prof. Bo Håkansson

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2013 in Source Code for Biology and Medicine
Verified
Journal Article
Open access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
RBRickard Brånemark
Rickard Brånemark
BHBo Håkansson
Bo Håkansson
Processing and pattern recognition of myoelectric signals have been at the core of prosthetic control research in the last decade. Although most studies agree on reporting the accuracy of predicting predefined movements, there is a significant amount of study-dependent variables that make high-resolution inter-study comparison practically impossible. As an effort to provide a common research platform for the development and evaluation of algorithms in prosthetic control, we introduce BioPatRec as open source software. BioPatRec allows a seamless implementation of a variety of algorithms in the fields of (1) Signal processing; (2) Feature selection and extraction; (3) Pattern recognition; and, (4) Real-time control. Furthermore, since the platform is highly modular and customizable, researchers from different fields can seamlessly benchmark their algorithms by applying them in prosthetic control, without necessarily knowing how to obtain and process bioelectric signals, or how to produce and evaluate physically meaningful outputs.

1 January 2014 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
NSNichlas Sander
Nichlas Sander
MKMorten Bak Kristoffersen
Morten Bak Kristoffersen
BHBo Håkansson
Bo Håkansson
RBRickard Brånemark
Rickard Brånemark
A variety of treatments have been historically used to alleviate phantom limb pain (PLP) with varying efficacy. Recently, virtual reality (VR) has been employed as a more sophisticated mirror therapy. Despite the advantages of VR over a conventional mirror, this approach has retained the use of the contralateral limb and is therefore restricted to unilateral amputees. Moreover, this strategy disregards the actual effort made by the patient to produce phantom motions. In this work, we investigate a treatment in which the virtual limb responds directly to myoelectric activity at the stump, while the illusion of a restored limb is enhanced through augmented reality (AR). Further, phantom motions are facilitated and encouraged through gaming.The proposed set of technologies was administered to a chronic PLP patient who has shown resistance to a variety of treatments (including mirror therapy) for 48 years. Individual and simultaneous phantom movements were predicted using myoelectric pattern recognition and were then used as input for VR and AR environments, as well as for a racing game.The sustained level of pain reported by the patient was gradually reduced to complete pain-free periods. The phantom posture initially reported as a strongly closed fist was gradually relaxed, interestingly resembling the neutral posture displayed by the virtual limb. The patient acquired the ability to freely move his phantom limb and a telescopic effect was observed where the position of the phantom hand was restored to the anatomically correct distance. More importantly, the effect of the interventions was positively and noticeably perceived by the patient and his relatives.Despite the limitation of a single case study, the successful results of the proposed system in a patient for whom other medical and non-medical treatments have been ineffective justifies and motivates further investigation in a wider study.

1 January 2012 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MOMax Ortiz-Catalan
Max Ortiz-Catalan
RBRickard Brånemark
Rickard Brånemark
BHBo Håkansson
Bo Håkansson
JDJean Delbeke
Jean Delbeke
The control of robotic prostheses based on pattern recognition algorithms is a widely studied subject that has shown promising results in acute experiments. The long-term implementation of this technology, however, has not yet been achieved due to practical issues that can be mainly attributed to the use of surface electrodes and their highly environmental dependency. This paper describes several implantable electrodes and discusses them as a solution for the natural control of artificial limbs. In this context “natural” is defined as producing control over limb movement analogous to that of an intact physiological system. This includes coordinated and simultaneous movements of different degrees of freedom. It also implies that the input signals must come from nerves or muscles that were originally meant to produce the intended movement and that feedback is perceived as originating in the missing limb without requiring burdensome levels of concentration. After scrutinizing different electrode designs and their clinical implementation, we concluded that the epimysial and cuff electrodes are currently promising candidates to achieving a long-term stable and natural control of robotic prosthetics, provided that communication from the electrodes to the outside of the body is guaranteed.

11 April 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
EMEnzo Mastinu
Enzo Mastinu
FCFrancesco CLEMENTE
Francesco CLEMENTE
PSPaolo Sassu
Paolo Sassu
OAOskar C. Aszmann
Oskar C. Aszmann
RBRickard Brånemark
Rickard Brånemark
MOMax Ortiz-Catalan
Max Ortiz-Catalan
Replacement of a lost limb by an artificial substitute is not yet ideal. Resolution and coordination of motor control approximating that of a biological limb could dramatically improve the functionality of prosthetic devices, and thus reduce the gap towards a suitable limb replacement. In this study, we investigated the control resolution and coordination exhibited by subjects with transhumeral amputation who were implanted with epimysial electrodes and an osseointegrated interface that provides bidirectional communication in addition to skeletal attachment (e-OPRA Implant System). We assessed control resolution and coordination in the context of routine and delicate grasping using the Pick and Lift and the Virtual Eggs Tests. Performance when utilizing implanted electrodes was compared with the standard-of-care technology for myoelectric prostheses, namely surface electrodes. Results showed that implanted electrodes provide superior controllability over the prosthetic terminal device compared to conventional surface electrodes. Significant improvements were found in the control of the grip force and its reliability during object transfer. However, these improvements failed to increase motor coordination, and surprisingly decreased the temporal correlation between grip and load forces observed with surface electrodes. We found that despite being more functional and reliable, prosthetic control via implanted electrodes still depended highly on visual feedback. Our findings indicate that incidental sensory feedback (visual, auditory, and osseoperceptive in this case) is insufficient for restoring natural grasp behavior in amputees, and support the idea that supplemental tactile sensory feedback is needed to learn and maintain the motor tasks internal model, which could ultimately restore natural grasp behavior in subjects using prosthetic hands.

1 December 2008 in Otology & Neurotology
Verified
Journal Article
Closed access
BHBo Håkansson
Bo Håkansson
MEMåns Eeg-Olofsson
Måns Eeg-Olofsson
SRSabine Reinfeldt
Sabine Reinfeldt
SSStefan Stenfelt
Stefan Stenfelt
GGGösta Granström
Gösta Granström
Percutaneous bone-anchored hearing aid (BAHA) is an important rehabilitation alternative for patients who have conductive or mixed hearing loss. However, these devices use a percutaneous and bone-anchored implant that has some drawbacks reported. A transcutaneous bone conduction implant system (BCI) is proposed as an alternative to the percutaneous system because it leaves the skin intact. The BCI transmits the signal to a permanently implanted transducer with an induction loop system through the intact skin. The aim of this study was to compare the electroacoustic performance of the BAHA Classic-300 with a full-scale BCI on a cadaver head in a sound field. The BCI comprised the audio processor of the vibrant sound bridge connected to a balanced vibration transducer (balanced electromagnetic separation transducer). Implants with snap abutments were placed in the parietal bone (Classic-300) and 15-mm deep in the temporal bone (BCI). The vibration responses at the ipsilateral and contralateral cochlear promontories were measured with a laser Doppler vibrometer, with the beam aimed through the ear canal. Results show that the BCI produces approximately 5 dB higher maximum output level and has a slightly lower distortion than the Classic-300 at the ipsilateral promontorium at speech frequencies. At the contralateral promontorium, the maximum output level was considerably lower for the BCI than for the Classic-300 except in the 1-2 kHz range, where it was similar. Present results support the proposal that a BCI system can be a realistic alternative to a BAHA.

28 January 2010 in International Journal of Audiology
Verified
Journal Article
Closed access
PDF file
BHBo Håkansson
Bo Håkansson
SRSabine Reinfeldt
Sabine Reinfeldt
MEMåns Eeg-Olofsson
Måns Eeg-Olofsson
PÖPer Östli
Per Östli
HTHamidreza Taghavi
Hamidreza Taghavi
GGGösta Granström
Gösta Granström
Percutaneous bone anchored hearing aids (BAHA) are today an important rehabilitation alternative for patients suffering from conductive or mixed hearing loss. Despite their success they are associated with drawbacks such as skin infections, accidental or spontaneous loss of the bone implant, and patient refusal for treatment due to stigma. A novel bone conduction implant (BCI) system has been proposed as an alternative to the BAHA system because it leaves the skin intact. Such a BCI system has now been developed and the encapsulated transducer uses a non-screw attachment to a hollow recess of the lateral portion of the temporal bone. The aim of this study is to describe the basic engineering principals and some preclinical results obtained with the new BCI system. Laser Doppler vibrometer measurements on three cadaver heads show that the new BCI system produces 0–10 dB higher maximum output acceleration level at the ipsilateral promontory relative to conventional ear-level BAHA at speech frequencies. At the contralateral promontory the maximum output acceleration level was considerably lower for the BCI than for the BAHA. Sumario Los auxiliares auditivos anclados al hueso (BAHA) en forma percutánea son hoy en día una alternativa importante de rehabilitación para pacientes que sufren de pérdidas auditiva conductivas o mixtas. A pesar de su éxito, ellos se asocian con algunos problemas, tales como infecciones de la piel, pérdida accidental o espontánea del implante óseo, o el rechazo del paciente al tratamiento por razones de estigma. Se ha prop-uesto un novedoso sistema de implante de conducción ósea (BCI) que deja la piel intacta, como una alternativa al sistema BAHA. El sistema de BCI ha sido ya desarrollado y el transductor encapsulado utiliza una unión sin tornillo a un receso hueco en la porción lateral del hueso temporal. El objetivo de este estudio es describir los principios básicos de ingeniería y algunos resultados pre-clínicos obtenidos con el nuevo sistema BCI. Mediciones con un vibrómetro Laser Doppler sobre tres cabezas de cadáver muestran que el nuevo sistema BCI produce un nivel más alto de aceleración máxima de salida de 0–10 dB en el promontorio ipsilateral, en relación con el BAHA convencional a la altura del oído, en las frecuencias del lenguaje. En el promontorio contralateral, el nivel máximo de aceleración de salida fue considerablemente más bajo para el BCI que para el BAHA.