This study presents the conception and development of a microwave (MW) applicator based on a TM010 cavity and a pulsed MW source, both custom-designed for evaluation of MW disruption of microalgae. The objective is the selective heating of microalgae immersed in their environment. The applicator enables exposing microalgae suspension to MW in continuous flow mode and monitoring the energy absorbed by the sample. The design was based on dielectric characteristics of microalgae in water, but other solvents might be considered. A tuning element ensures efficient MW coupling into the samples whose relative permittivity ranges from 10 to 80. The applicator includes a customized power supply operating a commercial magnetron source in pulse mode. The MW pulses are in the range of multiple kilowatts with adjustable duration in the microseconds range. The applicator enables to reach a power density in the microalgae sample beyond 10 10 W/m 3 . Preliminary proof-of-principle experiments of MW disruption on fresh microalgae biomass Auxenochlorella protothecoides followed by lipid extraction enabled almost complete lipid recovery, while yields were negligible on untreated samples. Total energy consumption was below 4.2 MJ per kg of dry microalgae. Finally, the applicator characteristics are promising for future upscaling and deployment in the industry.
2 March 2026 in Journal of the American Chemical Society
By control of the nanosecond pulsation, energy input, and flow, it is possible to achieve commercial-level hydrogen peroxide (H2O2) concentrations using only water and plasma in a continuous process while minimizing thermal degradation. Time-resolved ultrafast Optical Emission Spectroscopy was employed to observe the formation of reactive species, shedding light on the underlying mechanisms. This study also found that thermal degradation has a critical role, which was effectively managed through quenching of the plasma zone. A parametric scan of pulse duration and pulse repetition frequency of the microwave power showed a significant influence on H2O2 formation, whereby the mean power also plays an important role. Additionally, the H2O2 concentration was found to be inversely proportional to the water flow rate. A maximum concentration of 0.17 wt % was achieved with 1.2 g/kWh based on the absorbed power at a flow rate of 0.2 mL/min. This plasma reactor technology shows promise for further development as a decentralized solution for the green chemical synthesis of H2O2.
By control of the nanosecond pulsation, energy input and flow it is possible to achieve commercial-level hydrogen peroxide (H₂O₂) concentrations using only water and plasma in a continuous process while minimizing thermal degradation. Time-resolved ultrafast Optical Emission Spectroscopy was employed to observe the formation of reactive species, shedding light on the underlying mechanisms. This study also highlights the critical role of thermal degradation, which was effectively managed through quenching of the plasma zone. A parametric scan of pulse duration and pulse repetition frequency of the microwave power showed a significant influence on the H₂O₂ formation, whereby the mean power also plays an important role. Additionally, H₂O₂ concentration was found to be inversely proportional to the water flow rate. A maximum concentration of 0.17 wt% was achieved with 1.2 g/kWh based on the absorbed power at a flow rate of 0.2 mL/min. This plasma reactor technology shows promise for further development as a decentralized solution for green chemical synthesis of H2O2.
Ultrafast microwave power pulsation is demonstrated as an effective strategy to enhance CO₂ conversion in atmospheric-pressure plasma reactors. While initial experiments at several hundred watts in a compact coaxial plasma torch showed improved performance, the present study investigates the scalability of this approach to kilowatt-range microwave power. Conversion and energy efficiency were examined in two reactor configurations: a Surfaguide-based system (KIT) and a cavity-based plasma torch (IPP), and benchmarked against the compact coaxial torch. Both kilowatt-scale setups share similar microwave coupling schemes, power levels, reactor tubes, and gas injection geometries, but differ in afterglow treatment. The torch at IPP employs rapid nozzle-based quenching, whereas the Surfaguide-based reactor relies on slower cooling along an extended quartz tube. Stable plasma operation was achieved at pulsation peak powers of ~4 kW and pulse durations from sub-microseconds to microseconds, with stability limited to inter-pulse times of ~10 µs (cavity-based torch) and ~12 µs (Surfaguide-based reactor). In contrast to the coaxial torch, no plasma reignition regime was observed in either kilowatt-scale reactor, resulting in weaker plasma temperature modulation. Notably, the period-averaged gas temperature in the Surfaguide-based reactor exceeded that under continuous-wave operation. Under these conditions, relative enhancements of <40% in CO₂ conversion and <20% in energy efficiency were measured compared with continuous-wave operation. These improvements were largely suppressed in the torch at IPP, presumably due to rapid afterglow quenching. Finally, analysis of the instantaneous reflected microwave power provided qualitative insights into electron density dynamics during the power-OFF and power-ON phases.