Aude Silve

Dr. Aude Silve


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Scientific Reports
Verified
Journal Article
Open access
ASAude Silve
Aude Silve
ILIsabelle Leray
Isabelle Leray
CPClair Poignard
Clair Poignard
LMLluis M. Mir
Lluis M. Mir
The impact of external medium conductivity on the efficiency of the reversible permeabilisation caused by pulsed electric fields was investigated. Pulses of 12 ns, 102 ns or 100 μs were investigated. Whenever permeabilisation could be detected after the delivery of one single pulse, media of lower conductivity induced more efficient reversible permeabilisation and thus independently of the medium composition. Effect of medium conductivity can however be hidden by some saturation effects, for example when pulses are cumulated (use of trains of 8 pulses) or when the detection method is not sensitive enough. This explains the contradicting results that can be found in the literature. The new data are complementary to those of one of our previous study in which an opposite effect of the conductivity was highlighted. It stresses that the conductivity of the medium influences the reversible permeabilization by several ways. Moreover, these results clearly indicate that electropermeabilisation does not linearly depend on the energy delivered to the cells.

1 December 2018 in Bioresource Technology
Verified
Journal Article
Open access
ASAude Silve
Aude Silve
CKChua Boon Kian
Chua Boon Kian
IPIoannis Papachristou
Ioannis Papachristou
CKChristin Kubisch
Christin Kubisch
NNNatalja Nazarova
Natalja Nazarova
WFWolfgang Frey
Wolfgang Frey
Pulsed Electric Field (PEF) pre-treatment, applied on fresh microalgae Auxenochlorella protothecoides, induces spontaneous release of a substantial water fraction and enables subsequent lipid extraction using ethanol-hexane blends. In this study, fresh microalgae suspensions were treated with PEF and incubated under inert conditions. Incubation promotes the release of ions and carbohydrates and increases the yields of subsequent lipid extraction thus enabling a considerable reduction of PEF-treatment energy. With a 20 h incubation period at 25 °C, almost total lipid extraction is achieved with a specific PEF-treatment energy of only 0.25 MJ/kgDW. Incubation on ice remains beneficial but less efficient than at 25 °C. Additionally, incubating microalgae cells in suspension at 100gDW/L or in a dense paste, was almost equally efficient. Correlation between the different results suggests that spontaneous release of ions and carbohydrates facilitates more successful lipid extraction. A direct causality between the two phenomena remains to be demonstrated.

11 September 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
OGOlga Gorte
Olga Gorte
NNNatalja Nazarova
Natalja Nazarova
IPIoannis Papachristou
Ioannis Papachristou
RWRüdiger Wüstner
Rüdiger Wüstner
KLKlaus Leber
Klaus Leber
ASAude Silve
Aude Silve
This study reports on the use of pulsed electric field (PEF) as a pre-treatment step to enhance lipid extraction yield using extraction with ethanol-hexane blend on fresh oleaginous yeast Saitozyma podzolica. The yeasts were cultivated on nitrogen-depleted condition and had a lipid content of 26.4 ± 4.6% of dry weight. PEF-treatment was applied on the yeast suspension either directly after harvesting (unwashed route) or after a washing step (washed route) which induced a reduction of conductivity by a factor eight. In both cases, cell concentration was 20 g of biomass per liter of suspension. In the unwashed route, the lipid extraction efficiency increased from 7% (untreated) to 54% thanks to PEF-treatment. In case an additional washing step was added after PEF-treatment, up to 81% of the lipid content could be recovered. The washed route was even more efficient since lipid extraction yields increased from 26% (untreated) to 99% of total lipid. The energy input for the PEF-treatment never exceeded 150 kJ per liter of initial suspension. The best lipid recovery scenario was obtained using pulses of 1 μs, an electric field of 40 kV/cm and it required slightly less than 11 MJ/kgLIPID. This amount of energy can be further reduced by at least a factor five by optimizing the treatment and especially by increasing the concentration of the treated biomass. The process can be easily up-scaled and does not require any expensive handling of the biomass such as freezing or freeze-drying. These findings demonstrate the potential benefit of PEF-treatment in the downstream processing of oleaginous yeast. From a basic research point of view, the influence of conductivity on PEF energy requirements and extraction yields was examined, and results suggest a higher efficiency of PEF-treatment in terms of energy when treatment is performed at lower conductivity.

1 December 2015 in Bioelectrochemistry
Verified
Journal Article
Closed access
ASAude Silve
Aude Silve
ILIsabelle Leray
Isabelle Leray
MLMichael Leguèbe
Michael Leguèbe
CPClair Poignard
Clair Poignard
LMLluis M. Mir
Lluis M. Mir

25 February 2022 in Energy
Verified
Journal Article
Closed access
YZYi Zhang
Yi Zhang
SSSergey Soldatov
Sergey Soldatov
IPIoannis Papachristou
Ioannis Papachristou
NNNatalja Nazarova
Natalja Nazarova
GLGuido Link
Guido Link
ASAude Silve
Aude Silve

17 February 2012 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ASAude Silve
Aude Silve
RVRené Vezinet
René Vezinet
LMLluis M. Mir
Lluis M. Mir
Microsecond-duration electric pulses are widely used for research and therapeutic purposes. The most commonly used device for in vitro exposure to electric pulses is a standard electroporation cuvette. The use of nanosecond-duration electric pulses [nanosecond pulsed electromagnetic fields (nsPEFs) or nanopulses] is an emerging technology. For microsecond pulses, some dedicated generators with voltage regulation have been developed and allow one to easily impose a well-known voltage during biological experiments. However, it is not the case for nsPEF. The application of nsPEF thus requires considering the output impedance of the generator used and the impedance of the biological load because both impose the magnitude and the shape of the applied pulses. The model proposed here describes the behavior of the biological sample on a large frequency band (100 Hz to 3 GHz), including or not the exposure device. This model allows predicting the real electric pulses applied to biological samples and highlights the limitations induced by the use of standard electroporation cuvettes. Considering this kind of application device and the use of 10-ns-duration trapezoidal electric pulses, we evaluate the distortion of the pulses and also the impact of the output impedance of the generator on the steepness of the pulse rising and falling edges. This study is then transposed to potato tuber, a model currently used as a homogeneous biological tissue.