Seungchan Oh

Dr. Seungchan Oh


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HSHeewon Shin
Heewon Shin
JJJaeyeop Jung
Jaeyeop Jung
SOSeungchan Oh
Seungchan Oh
Kyeon HurKyeon Hur
Kyeon Hur
KIKenji Iba
Kenji Iba
BLByongjun Lee
Byongjun Lee
The responses of an inverter-based distributed generator (IBDG) to abnormal voltage and frequency are different from those of a conventional generator because of the inverter's operating modes. In particular, although the momentary cessation (MC) mode is essential to protecting the distribution system, the MC mode can affect the power system transient stability by temporarily ceasing significant amounts of IBDG generation. To mitigate these negative effects, this study analyzed the impacts of MC capability on the power system transient stability. First, the transient stability was analyzed in relation to MC capability using the single-machine equivalent (SIME) method. A critical MC operating point (CMCOP) was then proposed to assess the severity of a transient impact and to secure the transient stability under the contingency conditions. A case study based on the Korean power system validated the feasibility and effectiveness of the proposed method.

11 November 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
SOSeungchan Oh
Seungchan Oh
HSHeewon Shin
Heewon Shin
HCHwanhee Cho
Hwanhee Cho
BLByongjun Lee
Byongjun Lee
Efforts to reduce greenhouse gas emissions constitute a worldwide trend. According to this trend, there are many plans in place for the replacement of conventional electric power plants operating using fossil fuels with renewable energy sources (RESs). Owing to current needs to expand the RES penetration in accordance to a new National power system plan, the importance of RESs is increasing. The RES penetration imposes various impacts on the power system, including transient stability. Furthermore, the fact that they are distributed at multiple locations in the power system is also a factor which makes the transient impact analysis of RESs difficult. In this study, the transient impacts attributed to the penetration of RESs are analyzed and compared with the conventional Korean electric power system. To confirm the impact of the penetration of RESs on transient stability, the effect was analyzed based on a single machine equivalent (SIME) configuration. Simulations were conducted in accordance to the Korean power system by considering the anticipated RES penetration in 2030. The impact of RES on transient stability was provided by a change in CCT by increasing of the RES penetration.

1 March 2014 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
YLYun-Hwan Lee
Yun-Hwan Lee
BPBo-Hyun Park
Bo-Hyun Park
SOSeungchan Oh
Seungchan Oh
BLByongjun Lee
Byongjun Lee
JSJeong-Hoon Shin
Jeong-Hoon Shin
TKTae-Kyun Kim
Tae-Kyun Kim