Hwanhee Cho

Dr. Hwanhee Cho

Korea Railroad Research Institute
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
DKDOHYUK KIM
DOHYUK KIM
HCHwanhee Cho
Hwanhee Cho
BPBohyun Park
Bohyun Park
BLByongjun Lee
Byongjun Lee
The penetration of renewable energy sources (RESs) equipped with inverter-based control systems such as wind and solar plants are increasing. Therefore, the speed of the voltage controllers associated with inverter-based resources (IBRs) has a substantial impact on the stability of the interconnected grid. System strength evaluation is one of the important concerns in the integration of IBRs, and this strength is often evaluated in terms of the short circuit ratio (SCR) index. When IBRs are installed in an adjacent location, system strength can be weaker than evaluation by SCR. This study proposes an inverter interaction level short circuit ratio (IILSCR) method by tracing IBRs output flow. The IILSCR can accurately estimate system strength, wherein IBRs are connected in adjacent spots, by reflecting the interaction level between IBRs. The study also demonstrates the efficiency of IILSCR by applying this method to Institute of Electrical and Electronics Engineers (IEEE) 39 bus test system and future Korea power systems.

28 August 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
HCHwanhee Cho
Hwanhee Cho
SOSeungchan Oh
Seungchan Oh
SNSuchul Nam
Suchul Nam
BLByongjun Lee
Byongjun Lee
This study proposes a time‐series analysis approach and a non‐linear dynamics originated method to detect sub‐synchronous oscillation in power systems. Mathematical expressions of the fundamental instantaneous signal and sample discrete signal of peak values are derived to examine the phenomenon of interaction between power system components. The results of the circulating trajectory are shown in a two‐dimensional map of the calculated root‐mean‐square value and estimated Floquet multiplier when two signals of different modes are mixed. Without applying a digital filter or frequency decomposition, non‐linear oscillation detection is possible by monitoring a non‐linear oscillatory index based on the maximum Lyapunov exponent.

11 November 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
SOSeungchan Oh
Seungchan Oh
HSHeewon Shin
Heewon Shin
HCHwanhee Cho
Hwanhee Cho
BLByongjun Lee
Byongjun Lee
Efforts to reduce greenhouse gas emissions constitute a worldwide trend. According to this trend, there are many plans in place for the replacement of conventional electric power plants operating using fossil fuels with renewable energy sources (RESs). Owing to current needs to expand the RES penetration in accordance to a new National power system plan, the importance of RESs is increasing. The RES penetration imposes various impacts on the power system, including transient stability. Furthermore, the fact that they are distributed at multiple locations in the power system is also a factor which makes the transient impact analysis of RESs difficult. In this study, the transient impacts attributed to the penetration of RESs are analyzed and compared with the conventional Korean electric power system. To confirm the impact of the penetration of RESs on transient stability, the effect was analyzed based on a single machine equivalent (SIME) configuration. Simulations were conducted in accordance to the Korean power system by considering the anticipated RES penetration in 2030. The impact of RES on transient stability was provided by a change in CCT by increasing of the RES penetration.

21 February 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
NCNamki Choi
Namki Choi
BPBohyun Park
Bohyun Park
HCHwanhee Cho
Hwanhee Cho
BLByongjun Lee
Byongjun Lee
This study analyzed the impact of varying the momentary cessation (MC) voltage level on the short circuit current of inverter-based resources (IBRs). To analyze the impact of the IBR MC function on the short circuit current, this paper proposes an advanced IBR model for fault current calculation to reflect its fault characteristics and a scheme for analyzing the influence of MC on the short circuit current. Based on the proposed methods, the authors conducted case studies using planning data from the Korea Electric Power Corporation (KEPCO). The influence of MC was investigated on the IBRs located at the southwest side of the KEPCO systems by screening the fault currents while varying the MC voltage. This paper demonstrates that the minimum MC voltage level needed for the fault current not to exceed the circuit breaker (CB) capacity can be proposed through analyzing the impact of MC voltage level on the short circuit current. The test results based on the proposed scheme showed that the short circuit current to power systems could not violate CB capacity if IBRs adjusted the MC voltage level higher than the lowest MC voltage level.

1 September 2020 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
HNHyeokjin Noh
Hyeokjin Noh
HCHwanhee Cho
Hwanhee Cho
SLSeungryul Lee
Seungryul Lee
BLByongjun Lee
Byongjun Lee

22 July 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JJJaeyeop Jung
Jaeyeop Jung
HCHwanhee Cho
Hwanhee Cho
BPBohyun Park
Bohyun Park
SNSuchul Nam
Suchul Nam
Kyeon HurKyeon Hur
Kyeon Hur
BLByongjun Lee
Byongjun Lee
This study presents a new wide‐area voltage stability monitoring method using synchronised phasor measurements. The salient features of the proposed index are the following: (i) It ensures constancy, which is the ability to maintain the same scale even if the system changes. (ii) It is pseudo‐linear with respect to the power system stability level, which enhances intuitiveness for real‐time operation. Accordingly, stability can be uniformly compared in various situations, and thus, the index can be used as a solid criterion or threshold point for system operation. A verification study of the proposed index with regard to constancy is carried out using Korean power system operation data. Furthermore, an implementation of the proposed method for the Korean wide‐area monitoring system is presented, and it is demonstrated that the proposed index detects event more clearly than previous stability index through an actual event measured using phasor measurement units.