Two-photon imaging (TPI) microscopy, namely, two-photon excited fluorescence (TPEF), fluorescence lifetime imaging (FLIM), and second-harmonic generation (SHG) modalities, has emerged in the past years as a powerful tool for the examination of biological tissues. These modalities rely on different contrast mechanisms and are often used simultaneously to provide complementary information on morphology, metabolism, and structural properties of the imaged tissue. The cornea, being a transparent tissue, rich in collagen and with several cellular layers, is well-suited to be imaged by TPI microscopy. In this review, we discuss the physical principles behind TPI as well as its instrumentation. We also provide an overview of the current advances in TPI instrumentation and image analysis. We describe how TPI can be leveraged to retrieve unique information on the cornea and to complement the information provided by current clinical devices. The present state of corneal TPI is outlined. Finally, we discuss the obstacles that must be overcome and offer perspectives and outlooks to make clinical TPI of the human cornea a reality.
1 June 2023 in Journal of Cataract & Refractive Surgery
Purpose: To evaluate the 1-year visual and tomographic results of customized crosslinking using excimer laser–assisted epithelium removal and topography-guided irradiation in the treatment of progressive keratoconus. Setting: Coimbra Ophthalmology Unit, Private Practice, Coimbra, Portugal. Design: Prospective nonrandomized clinical trial. Methods: Eyes with documented progressive keratoconus were enrolled. After de-epithelialization with phototherapeutic keratectomy, customized UV irradiation was performed, designed as 3 concentric circular areas centered on the thinnest point (Mosaic System). Energy exposure was 5.4 J/cm2 in the outer circle and then increased centripetally to 7.2 J/cm2 and 10 J/cm2. Corrected distance visual acuity (CDVA), refractive outcomes, and Scheimpflug tomographies (Allegro Oculyzer) were assessed at baseline, and 6 months, and 12 months postoperatively. Results: 37 eyes of 32 patients were enrolled in this prospective study. The mean diameter for treated areas was 6.17 ± 0.80 mm, 4.45 ± 0.47 mm, and 2.58 ± 0.14 mm for the outer, medium, and inner circle, respectively. At the 1-year follow-up, the mean CDVA improved significantly from 0.38 ± 0.19 to 0.20 ± 0.16 logMAR (P < .01), with 34 (91.89%) of the 37 eyes retaining or improving CDVA. The mean preoperative minimum pachymetry decreased from 449.26 ± 41.62 to 443.26 ± 41.06 μm (P = .02). The maximum keratometry decreased significantly from 58.50 ± 7.84 to 57.05 ± 7.27 diopters (P < .01). After 1 year, 34 eyes (91.89%) showed no signs of progression. Conclusions: 1 year postoperatively, patients showed a significant improvement in visual acuity while achieving stabilization of disease progression.
At the age of 43 years-old, a man was left with bilateral limbal stem cell deficiency after an ocular alkaline burn with lime, which resulted in corneal opacification. After multiple unsuccessful surgical attempts to restore vision, including penetrating keratoplasties and Boston keratoprosthesis, visual acuity was counting fingers in the left eye. At 73 years of age, the patient underwent another surgery in his left eye. Cauterization of neovessels and removal of the vascular pannus were followed by partial excision of Tenon’s capsule. Penetrating keratoplasty was followed by an intrastromal injection of anti-VEGF (vascular endothelial growth factor), and the ocular surface was covered with amniotic membrane. Postoperatively, the graft was clear with no signs of inflammation; vision improved to 20/50 and remained stable throughout the following two years. Herein we describe some adjunctive procedures that might have delayed failure and rejection of the corneal graft. This case demonstrates the difficulties in treating bilateral limbal stem cell deficiency in a tertiary eye care center with no capacity to perform stem cell therapy.
Purpose: To evaluate the intrasession repeatability and agreement in keratometric and wavefront measurements among three different instruments (Pentacam HR, Nidek OPD-Scan III [OPD], and Zeiss i-Profiler Plus [IPROF]) in a pediatric population with various clinical features. Methods: This cross-sectional study included 217 eyes from 114 patients aged 6 to 17 years with different clinical features. The patients were divided into five groups: one control group (C) and four other groups, each presenting with keratoconus (KC), ocular allergy (OA), high astigmatism, or Down syndrome (DS). Statistical analyses included the intraclass correlation coefficient (ICC) for repeatability and Bland-Altman plots for agreement. Results: The findings demonstrated excellent repeatability of keratometric parameters across all devices (e.g., K1 ICC: 99.53% for Pentacam, 98.10% for OPD, and 98.31% for IPROF). The Pentacam showed superior repeatability for aberrometry indices in the KC group, with ICC values exceeding 98% for high-order aberration root mean square (HOA RMS) and Zernike polynomials. However, in the DS group, repeatability was significantly reduced for certain parameters, such as the index of surface variance (ICC: 40.13%) and HOA RMS (ICC: 42.86%). Bland-Altman plots revealed variations among devices in asphericity, vertical coma, and HOA RMS, with the KC group exhibiting broader limits of agreement compared to the control group. Conclusion: All three instruments showed good repeatability, with the Pentacam demonstrating superior reliability across all parameters, including aberrometry. However, agreement between devices was poor for key indices in patients with KC and DS.
The study aimed to evaluate the precision of different Pentacam indices in diagnosing keratoconus (KC) in pediatric patients with and without Down Syndrome (DS) and determine suitable cutoff values. This prospective multicenter cross-sectional study evaluated 216 eyes of 131 patients aged 6–18 years (mean age 12.5 ± 3.2 years) using Pentacam. Patients were categorized into four groups: KC, forme fruste keratoconus (FK), DS, and control, excluding DS patients with topographic KC. Receiver operating characteristic curves were generated to determine the optimal cutoff points and compare the accuracy in identifying KC and FK in patients with and without DS. In DS patients, corneal morphology resembled KC features. The most effective indices for distinguishing KC in DS patients were the average pachymetric progression index (AUC = 0.961), higher-order aberration of the anterior cornea (AUC = 0.953), anterior elevation (AUC = 0.946), posterior elevation (AUC = 0.947), index of vertical asymmetry (AUC = 0.943), and Belin/Ambrosio enhanced ectasia total derivation value (AUC = 0.941). None of the indices showed good accuracy for distinguishing FK in DS patients. The thresholds of these indices differed significantly from non-DS patients. The results highlighted the need for DS-specific cutoff values to avoid false-positive or false-negative diagnoses in this population.