Renato souza oliveira

Dr. Renato souza oliveira

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2010 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RORenato souza oliveira
Renato souza oliveira
MRMoacyr Rigueiro
Moacyr Rigueiro
AVAna C Vieira
Ana C Vieira
DFDenise de Freitas
Denise de Freitas
ESElcio Sato
Elcio Sato

6 November 2024 in Cornea
Verified
Journal Article
Closed access
RORenato souza oliveira
Renato souza oliveira
JGJoão Quadrado Gil
João Quadrado Gil
ARAndreia Rosa
Andreia Rosa
MQMaria João Quadrado
Maria João Quadrado
MCMauro Campos
Mauro Campos
Purpose: To assess the accuracy of various Pentacam indices in distinguishing keratoconus (KC) in pediatric patients with high astigmatism and to establish appropriate cutoff values. Methods: This prospective multicenter cross-sectional study included 312 eyes from 167 patients aged 6 to 18 years (mean age, 13.1 ± 3.2 years) evaluated with Oculus Pentacam HR. Patients were categorized into 4 groups: KC, forme fruste keratoconus, astigmatism greater than 2 diopters (Cyl2D), and control. A subgroup of Cyl2D comprised patients with astigmatism greater than 4 diopters (Cyl4D). Twenty-three Pentacam indices were analyzed, and receiver operating characteristic curves determined optimal cutoff points, sensitivity, and specificity. Results: The best indices for distinguishing KC from Cyl2D were high-order aberration root mean square of the anterior corneal surface (area under the receiver operating characteristic curve 0.987), Belin/Ambrosio enhanced ectasia total derivation (0.971), index of vertical asymmetry (0.971), average pachymetric progression index (0.962), maximum Ambrosio relational thickness (0.960), posterior elevation (0.952), and anterior elevation (0.948). The accuracy of these indices was highest in the control group and lowest in the Cyl4D group. Area under the receiver operating characteristic curve was significantly lower for fruste keratoconus than KC. Optimal cutoff values were higher for astigmatic patients than for those with no refractive error. Conclusions: Most indices effectively distinguished between KC and normal pediatric patients. For individuals with high astigmatism, we suggest focusing on specific indices such as high-order aberration root mean square, Belin/Ambrosio enhanced ectasia total derivation value, maximum Ambrosio relational thickness, average pachymetric progression index, and index of vertical asymmetry. Optimal cutoff points for these patients were higher than those for nonastigmatic children and differed from adult populations.

24 December 2024 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
CCCelso Costa
Celso Costa
RORenato souza oliveira
Renato souza oliveira
JGJoão Gil
João Gil
ECEsmeralda Costa
Esmeralda Costa
CTCristina Tavares
Cristina Tavares
JMJoaquim Murta
Joaquim Murta
Introduction: Keratoconus patients turn to the internet for answers to their disease expectations. Webpages are not filtered or submitted to evaluation before getting published. We aim to evaluate the quality and readability of the online information regarding keratoconus in Portugal and Brazil. Methods: Two independent ophthalmologists and one ophthalmologist supervisor evaluated 30 Portuguese and 30 Brazilian websites by order of appearance in Google with the word “Queratocone” and “Ceratocone”, respectively. Two quality scores were used: a quality index of consumer health information (DISCERN) and the Journal of the American Medical Association (JAMA) benchmark. Readability was evaluated with 3 scores: FleschKincaid Reading Ease (FRE), FleschKincaid Grade (FKG) and Automated Readability Index (ARI). Results: Sites from private hospitals or clinics were the most prevalent in both countries, followed by health platform sites. Final JAMA benchmark was 1.13 ± 1.18 in Portugal and 1.07 ± 1.00 in Brazil. Final DISCERN was 34.07 ± 11.71 in Portugal and 38.17 ± 10.51 in Brazil. FRE and FKG scores denoted “difficult to read” and “college school level” in both countries; ARI denoted “professor” level in Portugal and “college student” level in Brazil needed to understand the text, a statistically significant difference. There was no correlation between Google ranking and quality and readability scores. Discussion and Conclusions: The information on keratoconus available online to Portuguese-speaking patients is of poor quality and difficult to interpret. Ophthalmologists have a shared responsibility to tackle this challenge through multifold efforts. Educating our patients on how to find reputable websites can help them navigate their life with keratoconus.

23 January 2025 in Cornea
Verified
Journal Article
Closed access
RORenato souza oliveira
Renato souza oliveira
JGJoão Quadrado Gil
João Quadrado Gil
ARAndreia Rosa
Andreia Rosa
MQMaria João Quadrado
Maria João Quadrado
MCMauro Campos
Mauro Campos

10 November 2025 in Journal of Ophthalmic and Vision Research
Verified
Journal Article
Open access
PDF file
RORenato souza oliveira
Renato souza oliveira
JGJoao Quadrado Gil
Joao Quadrado Gil
MQMaria Quadrado
Maria Quadrado
MCMauro Silveira de Queiroz Campos
Mauro Silveira de Queiroz Campos
Purpose: To evaluate the intrasession repeatability and agreement in keratometric and wavefront measurements among three different instruments (Pentacam HR, Nidek OPD-Scan III [OPD], and Zeiss i-Profiler Plus [IPROF]) in a pediatric population with various clinical features. Methods: This cross-sectional study included 217 eyes from 114 patients aged 6 to 17 years with different clinical features. The patients were divided into five groups: one control group (C) and four other groups, each presenting with keratoconus (KC), ocular allergy (OA), high astigmatism, or Down syndrome (DS). Statistical analyses included the intraclass correlation coefficient (ICC) for repeatability and Bland-Altman plots for agreement. Results: The findings demonstrated excellent repeatability of keratometric parameters across all devices (e.g., K1 ICC: 99.53% for Pentacam, 98.10% for OPD, and 98.31% for IPROF). The Pentacam showed superior repeatability for aberrometry indices in the KC group, with ICC values exceeding 98% for high-order aberration root mean square (HOA RMS) and Zernike polynomials. However, in the DS group, repeatability was significantly reduced for certain parameters, such as the index of surface variance (ICC: 40.13%) and HOA RMS (ICC: 42.86%). Bland-Altman plots revealed variations among devices in asphericity, vertical coma, and HOA RMS, with the KC group exhibiting broader limits of agreement compared to the control group. Conclusion: All three instruments showed good repeatability, with the Pentacam demonstrating superior reliability across all parameters, including aberrometry. However, agreement between devices was poor for key indices in patients with KC and DS.

13 July 2021 in Journal of Cataract & Refractive Surgery Online Case Reports
Verified
Journal Article
Closed access
RORenato souza oliveira
Renato souza oliveira
TKTatiana Klejnberg
Tatiana Klejnberg
CKCelso Klejnberg
Celso Klejnberg
MCMauro Campos
Mauro Campos
A 42-year-old woman, who had undergone photorefractive keratectomy (PRK) 12 years earlier, complained of blurring of vision within 2 weeks of chikungunya infection. A central corneal stromal haze was observed in the left eye. Her corrected distance visual acuity was 20/200. The haze did not improve despite the use of topical corticosteroids; however, corneal clarity was restored, and vision improved with phototherapeutic keratectomy (PTK) and treatment with mitomycin-C (MMC) 0.02%. Late-onset stromal scarring can be triggered by systemic infection even years after PRK. PTK with MMC may be an effective treatment option for late-onset scars.