Roland Heck

Dr. Roland Heck

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2017 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
BGBjörn Goebel
Björn Goebel
RHRoland Heck
Roland Heck
AHAli Hamadanchi
Ali Hamadanchi
SOSylvia Otto
Sylvia Otto
TDTorsten Doenst
Torsten Doenst
TPTudor C Poerner
Tudor C Poerner
Vena contracta area (VCA3D), derived by 3D colour Doppler echocardiography, has already been validated against cardiac magnetic resonance imaging, but the number of clinical studies to define cut-off values for grading of mitral regurgitation (MR) is limited. Aim of the study was to assess VCA3D in a large population of patients with functional (FMR) and degenerative MR (DMR). Transoesophageal echocardiography was performed in 500 patients with MR. The following 2D parameters were assessed for grading of MR: vena contracta width, effective regurgitant orifice area (EROAPISA), and regurgitation volume (RVPISA). VCA3D and the corresponding regurgitation volume (RVVCA) were quantified using 3D colour Doppler loop and CW Doppler tracing of the regurgitant jet. In 104 patients a 3D dataset of the left ventricle (LV) and the left ventricular outflow tract (LVOT) was acquired. As a reference method, regurgitation volume (RV3D) was calculated as difference between LV overall and LVOT stroke volumes. For prediction of severe MR, VCA3D yielded higher values of area under the ROC curve compared to EROAPISA (overall patient group 0.98 for VCA3D vs. 0.90 for EROAPISA, P < 0.001; FMR group 0.97 for VCA3D vs. 0.92 for EROAPISA, P = 0.002). RVVCA correlated closer with RV3D compared to RVPISA (r = 0.96 for RVPISA, r = 0.79 for RVPISA). This study delivers cut-off values for VCA3D in patients with different types of MR. VCA3D is a robust parameter for quantification of MR, showing a good correlation with the reference method using 3D datasets of LV.

1 April 2019 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
JKJan Knierim
Jan Knierim
RHRoland Heck
Roland Heck
MPMarina Pieri
Marina Pieri
FSFelix Schoenrath
Felix Schoenrath
SSSajjad Soltani
Sajjad Soltani
EPEvgenij Potapov
Evgenij Potapov

15 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LPLeonard Pitts
Leonard Pitts
MKMarkus Kofler
Markus Kofler
MMMatteo Montagner
Matteo Montagner
RHRoland Heck
Roland Heck
JIJasper Iske
Jasper Iske
JKJörg Kempfert
Jörg Kempfert
Background: Perioperative stroke remains a devastating complication in the operative treatment of acute type A aortic dissection. To reduce the risk of perioperative stroke, different perfusion techniques can be applied. A consensus on the preferred cerebral protection strategy does not exist. Methods: To provide an overview about the different cerebral protection strategies, literature research on Medline/PubMed was performed. All available original articles reporting on cerebral protection in surgery for acute type A aortic dissection and neurologic outcomes since 2010 were included. Results: Antegrade and retrograde cerebral perfusion may provide similar neurological outcomes while outperforming deep hypothermic circulatory arrest. The choice of arterial cannulation site and chosen level of hypothermia are influencing factors for perioperative stroke. Conclusions: Deep hypothermic circulatory arrest is not recommended as the sole cerebral protection technique. Antegrade and retrograde cerebral perfusion are today’s standard to provide cerebral protection during aortic surgery. Bilateral antegrade cerebral perfusion potentially leads to superior outcomes during prolonged circulatory arrest times between 30 and 50 min. Arterial cannulation sites with antegrade perfusion (axillary, central or carotid artery) in combination with moderate hypothermia seem to be advantageous. Every concept should be complemented by adequate intraoperative neuromonitoring.

15 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JMJohanna Katharina Rose von Mackensen
Johanna Katharina Rose von Mackensen
VZVanessa Ivana Tara Zwaans
Vanessa Ivana Tara Zwaans
ASAhmed El Shazly
Ahmed El Shazly
KPKarel M. Van Praet
Karel M. Van Praet
RHRoland Heck
Roland Heck
LWLeonhard Wert
Leonhard Wert
Background: Takotsubo syndrome is, by definition, a reversible form of acute heart failure. If cardiac output is severely reduced, Takotsubo syndrome can cause cardiogenic shock, and mechanical circulatory support can serve as a bridge to recovery. To date, there are no recommendations on when to use mechanical circulatory support and on which device is particularly effective in this context. Our aim was to determine the best treatment strategy. Methods: A systematic literature research and analysis of individual patient data was performed in MEDLINE/PubMed according to PRISMA guidelines. Our research considered original works published until 31 July 2023. Results: A total of 93 publications that met the inclusion criteria were identified, providing individual data from 124 patients. Of these, 62 (50%) were treated with veno-arterial extracorporeal life support (va-ECLS), and 44 (35.5%) received a microaxial left ventricular assist device (Impella). Eighteen patients received an Impella CP and twenty-one an Impella 2.5. An intra-aortic balloon pump (IABP) without other devices was used in only 13 patients (10.5%), while other devices (BiVAD or Tandem Heart) were used in 5 patients (4%). The median initial left ventricular ejection fraction was 20%, with no difference between the four device groups except for the IABP group, which was less affected by cardiac output failure (p = 0.015). The overall survival was 86.3%. Compared to the other groups, the time to cardiac recovery was shorter with Impella (p < 0.001). Conclusions: Though the Impella treatment is new, our analysis may show a significant benefit of Impella compared to other MCS strategies for cardiogenic shock in Takotsubo syndrome.

19 May 2021 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
MMMatteo Montagner
Matteo Montagner
MKMarkus Kofler
Markus Kofler
RHRoland Heck
Roland Heck
SBSemih Buz
Semih Buz
CSChristoph Starck
Christoph Starck
JKJörg Kempfert
Jörg Kempfert
The goal of the present study is to investigate changes in supra-aortic vessel perfusion after implantation of the non-covered Ascyrus Medical Dissection Stent (AMDS) for surgical treatment of acute type A aortic dissection. From 2017 to 2020, 16 consecutive patients treated with AMDS and involvement (dissection to total occlusion) of at least 1 supra-aortic vessel were included in the study. Centre-line based computed tomography measurements of true, false and total lumen area using Terarecon software were performed before and after surgery. Changes in the true lumen area were indexed to the entire vessel area. The paired sample t-test was used to assess the significance of the observed differences. Analysis of supra-aortic vessels and the descending aorta showed significant improvement in true lumen perfusion after the AMDS was implanted. The indexed true lumen area increased postoperatively by 72%, 112% and 30% in the innominate, right and left common carotid arteries, respectively. Total occlusions of both common carotid arteries recovered completely after surgical treatment. The proximal- and the mid-descending aorta showed a 78% and 48% improvement of the indexed true lumen area, respectively. Arch repair using AMDS shows promising results in the treatment of acute type A aortic dissection. Quantitative measurements of true and false lumen perfusion demonstrated a significant increase in true lumen area and a 100% regression of totally occluded supra-aortic branches. Further examination in a larger cohort of patients and comparison with isolated hemiarch repair are needed to confirm positive vascular remodelling after an AMDS implant.

9 April 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
MMMatteo Montagner
Matteo Montagner
MKMarkus Kofler
Markus Kofler
LPLeonard Pitts
Leonard Pitts
RHRoland Heck
Roland Heck
SBSemih Buz
Semih Buz
JKJörg Kempfert
Jörg Kempfert
OBJECTIVES: The present study aims to investigate outcomes after the surgical treatment of acute type A aortic dissection in regard to three available selective cerebral perfusion strategies. METHODS: From 2000 to 2019, patients were selected based on the employment of either retrograde cerebral perfusion (RCP), unilateral antegrade cerebral perfusion (uACP) or bilateral antegrade cerebral perfusion (bACP) during open zone-0 anastomosis. Propensity score TriMatch analysis considering several preoperative and intraoperative variables was used to identify well-balanced triplets. The primary end point of the study was a new cerebral operation-related neurologic deficit. RESULTS: Operative times (operation time, cardiopulmonary bypass time, reperfusion time) were significantly longer in the RCP group, in which deeper hypothermia was applied (27.5 [24–28], 28 [26–28] and 16 [16–17]°C for uACP, bACP and RCP, respectively, P-value <0.001). The RCP group showed higher red blood cell concentrates and fresh frozen plasma transfusion rates. No significant difference of new cerebral operation-related neurologic deficit was observed between the 3 groups (12.9% vs 12.9% vs 11.3% for RCP, uACP and bACP, P-value = 0.86). In addition, 30-day mortality showed similar distribution independently of the cerebral perfusion strategy adopted (17.7% vs 14.5% vs 17.7% for RCP, uACP and bACP, P-value = 0.86). CONCLUSIONS: However, based on a small sample size, the comparison showed no relevant differences in terms of neurologic outcome and 30-day mortality, confirming RCP, uACP and bACP as safe and reproducible selective cerebral perfusion strategies in surgery for acute type A aortic dissection.