Most computed tomography (CT) denoising algorithms have been evaluated using image quality analysis (IQA) methods developed for natural image, which do not adequately capture the texture details in medical imaging. Radiomics is an emerging image analysis technique that extracts texture information to provide a more objective basis for medical imaging diagnostics, overcoming the subjective nature of traditional methods. By utilizing the difficulty of reproducing radiomics features under different imaging protocols, we can more accurately evaluate the performance of CT denoising algorithms. We introduced radiomic feature reproducibility analysis as an evaluation metric for a denoising algorithm. Also, we proposed a low-dose CT denoising method based on a generative adversarial network (GAN), which outperformed well-known CT denoising methods. Although the proposed model produced excellent results visually, the traditional image assessment metrics such as peak signal-to-noise ratio and structural similarity failed to show distinctive performance differences between the proposed method and the conventional ones. However, radiomic feature reproducibility analysis provided a distinctive assessment of the CT denoising performance. Furthermore, radiomic feature reproducibility analysis allowed fine-tuning of the hyper-parameters of the GAN. We demonstrated that the well-tuned GAN architecture outperforms the well-known CT denoising methods. Our study is the first to introduce radiomics reproducibility analysis as an evaluation metric for CT denoising. We look forward that the study may bridge the gap between traditional objective and subjective evaluations in the clinical medical imaging field.
We assessed the feasibility of using deep learning-based image harmonization to improve the reproducibility of radiomics features in abdominal CT scans. In CT imaging, harmonization adjusts images from different institutions to ensure consistency despite variations in scanners and acquisition protocols. This process is essential because such differences can lead to variability in radiomics features, affecting reproducibility and accuracy. Harmonizing images minimizes these inconsistencies, supporting more reliable and clinically applicable results across diverse settings. A pre-trained harmonization algorithm was applied to 63 dual-energy abdominal CT images, which were reconstructed into four different types, and 10 regions of interest (ROIs) were analyzed. From the original 455 radiomics features per ROI, 387 were used after excluding redundant features. Reproducibility was measured using the intraclass correlation coefficient (ICC), with a threshold of ICC ≥ 0.85 indicating acceptable reproducibility. The region-based analysis revealed significant improvements in reproducibility post-harmonization, especially in vessel features, which increased from 14% to 69%. Other regions, including the spleen, kidney, muscle, and liver parenchyma, also saw notable improvements, although air reproducibility slightly decreased from 95% to 94%, impacting only a few features. In patient-based analysis, reproducible features increased from 18% to 65%, with an average of 179 additional reproducible features per patient after harmonization. These results demonstrate that deep learning-based harmonization can significantly enhance the reproducibility of radiomics features in abdominal CT, offering promising potential for advancing radiomics development and its clinical applications.
19 July 2024 in IEEE Journal of Biomedical and Health Informatics
Heart auscultation is a simple and inexpensive first-line diagnostic test for the early screening of heart abnormalities. A phonocardiogram (PCG) is a digital recording of an analog heart sound acquired using an electronic stethoscope. A computerized algorithm for PCG analysis can aid in detecting abnormal signal patterns and support the clinical use of auscultation. It is important to detect fundamental components, such as the first and second heart sounds (S1 and S2), to accurately diagnose heart abnormalities. In this study, we developed a fully convolutional hybrid fusion network to identify S1 and S2 locations in PCG. It enables timewise, high-level feature fusion from dimensionally heterogeneous features: 1D envelope and 2D spectral features. For the fusion of heterogeneous features, we proposed a novel convolutional multimodal factorized bilinear pooling approach that enables high-level fusion without temporal distortion. We experimentally demonstrated the benefits of the comprehensive interpretation of heterogeneous features, with the proposed method outperforming other state-of-the-art PCG segmentation methods. To the best of our knowledge, this is the first study to interpret heterogeneous features through a high level of feature fusion in PCG analysis.
Computed tomography (CT) imaging is vital for diagnosing and monitoring diseases in both humans and animals, yet radiation exposure remains a significant concern, especially in animal imaging. Low-dose CT (LDCT) minimizes radiation exposure but often compromises image quality due to a reduced signal-to-noise ratio (SNR). Recent advancements in deep learning, particularly with CycleGAN, offer promising solutions for denoising LDCT images, though challenges in preserving anatomical detail and image sharpness persist. This study introduces a novel framework tailored for animal LDCT imaging, integrating deep learning techniques within the CycleGAN architecture. Key components include BlurPool for mitigating high-resolution image distortion, PixelShuffle for enhancing expressiveness, hierarchical feature synthesis (HFS) networks for feature retention, and spatial channel squeeze excitation (scSE) blocks for contrast reproduction. Additionally, a multi-scale discriminator enhances detail assessment, supporting effective adversarial learning. Rigorous experimentation on veterinary CT images demonstrates our framework’s superiority over traditional denoising methods, achieving significant improvements in noise reduction, contrast enhancement, and anatomical structure preservation. Extensive evaluations show that our method achieves a precision of 0.93 and a recall of 0.94. This validates our approach’s efficacy, highlighting its potential to enhance diagnostic accuracy in veterinary imaging. We confirm the scSE method’s critical role in optimizing performance, and robustness to input variations underscores its practical utility.