Yeonggul Jang

Mr. Yeonggul Jang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SKSekeun Kim
Sekeun Kim
ZJZhenxiang Jiang
Zhenxiang Jiang
BZByron A. Zambrano
Byron A. Zambrano
YJYeonggul Jang
Yeonggul Jang
SBSeungik Baek
Seungik Baek
HCHyuk-Jae Chang
Hyuk-Jae Chang
Prediction of abdominal aortic aneurysm (AAA) growth is of essential importance for the early treatment and surgical intervention of AAA. Capturing key features of vascular growth, such as blood flow and intraluminal thrombus (ILT) accumulation play a crucial role in uncovering the intricated mechanism of vascular adaptation, which can ultimately enhance AAA growth prediction capabilities. However, local correlations between hemodynamic metrics, biological and morphological characteristics, and AAA growth rates present high inter-patient variability that results in that the temporal-spatial biochemical and mechanical processes are still not fully understood. Hence, this study aims to integrate the physics-based knowledge with deep learning with a patch-based convolutional neural network (CNN) approach by incorporating important multiphysical features relating to its pathogenesis for validating its impact on AAA growth prediction. For this task, we observe that the unstructured multiphysical features cannot be directly employed in the kernel-based CNN. To tackle this issue, we propose a parameterization of features to leverage the spatio-temporal relations between multiphysical features. The proposed architecture was tested on different combinations of four features including radius, intraluminal thrombus thickness, time-average wall shear stress, and growth rate from 54 patients with 5-fold cross-validation with two metrics, a root mean squared error (RMSE) and relative error (RE). We conduct extensive experiments on AAA patients, the results show the effect of leveraging multiphysical features and demonstrate the superiority of the presented architecture to previous state-of-the-art methods in AAA growth prediction.

1 June 2024 in Cardiovascular Diagnosis and Therapy
Verified
Journal Article
Open access
PDF file
JPJiesuck Park
Jiesuck Park
JJJaeik Jeon
Jaeik Jeon
YYYeonyee E. Yoon
Yeonyee E. Yoon
YJYeonggul Jang
Yeonggul Jang
JKJiyeon Kim
Jiyeon Kim
HCHyuk-Jae Chang
Hyuk-Jae Chang
Background: Evaluating left ventricular diastolic function (LVDF) is crucial in echocardiography; however, the complexity and time demands of current guidelines challenge clinical use. This study aimed to develop an artificial intelligence (AI)-based framework for automatic LVDF assessment to reduce subjectivity and improve accuracy and outcome prediction. Methods: We developed an AI-based LVDF assessment framework using a nationwide echocardiographic dataset from five tertiary hospitals. This framework automatically identifies views, calculates diastolic parameters, including mitral inflow and annular velocities (E/A ratio, e’ velocity, and E/e’ ratio), maximal tricuspid regurgitation velocity, left atrial (LA) volume index, and left atrial reservoir strain (LARS). Subsequently, it grades LVDF according to guidelines. The AI-framework was validated on an external dataset composed of randomly screened 173 outpatients who underwent transthoracic echocardiography with suspicion for diastolic dysfunction and 33 individuals from medical check-ups with normal echocardiograms at Seoul National University Bundang Hospital, tertiary medical center in Korea, between May 2012 and June 2022. Additionally, we assessed the predictive value of AI-derived diastolic parameters and LVDF grades for a clinical endpoint, defined as a composite of all-cause death and hospitalization for heart failure, using Cox-regression risk modelling. Results: In an evaluation with 200 echocardiographic examinations (167 suspected diastolic dysfunction patients, 33 controls), it achieves an overall accuracy of 99.1% in identifying necessary views. Strong correlations (Pearson coefficient 0.901–0.959) were observed between AI-derived and manually-derived measurements of diastolic parameters, including LARS as well as conventional parameters. When following the guidelines, whether utilizing AI-derived or manually-derived parameters, the evaluation of LVDF consistently showed high concordance rates (94%). However, both methods exhibited lower concordance rates with the clinician’s prior assessments (77.5% and 78.5%, respectively). Importantly, both AI-derived and manually-derived LVDF grades independently demonstrated significant prognostic value [adjusted hazard ratio (HR) =3.03; P=0.03 and adjusted HR =2.75; P=0.04, respectively] for predicting clinical outcome. In contrast, the clinician’s prior grading lost its significance as a prognostic indicator after adjusting for clinical risk factors (adjusted HR =1.63; P=0.36). AI-derived LARS values significantly decreased with worsening LVDF (P for trend <0.001), and low LARS (<17%) was associated with increased risk for the clinical outcome (Log-rank P=0.04) relative to that for preserved LARS (≥17%). Conclusions: Our AI-based approach for automatic LVDF assessment on echocardiography is feasible, potentially enhancing clinical diagnosis and outcome prediction.

1 January 2024 in Korean Circulation Journal
Verified
Journal Article
Open access
PDF file
YJYeonggul Jang
Yeonggul Jang
HCHyejung Choi
Hyejung Choi
YYYeonyee E. Yoon
Yeonyee E. Yoon
JJJaeik Jeon
Jaeik Jeon
HKHyejin Kim
Hyejin Kim
HCHyuk-Jae Chang
Hyuk-Jae Chang
Jang Y, et al. Korean Circ J. 2024 Aug;54:e103. https://doi.org/10.4070/kcj.2024.0060

30 April 2020 in IEEE Access
Verified
Journal Article
Open access
SJSunghee Jung
Sunghee Jung
SLSoochahn Lee
Soochahn Lee
BJByunghwan Jeon
Byunghwan Jeon
YJYeonggul Jang
Yeonggul Jang
HCHyuk-Jae Chang
Hyuk-Jae Chang
Motion artifacts may occur in coronary computed tomography angiography (CCTA) due to the heartbeat and impede the clinicianb’s diagnosis of coronary arterial diseases. Thus, motion artifact correction of the coronary artery is required to quantify the risk of disease more accurately. We present a novel method based on deep learning for motion artifact correction in CCTA. Because the image of the coronary artery without motion (the ground-truth data required in supervised deep learning) is medically unattainable, we apply a style transfer method to 2D image patches cropped from full-phase 4D computed tomography (CT) to synthesize these images. We then train a convolutional neural network (CNN) for motion artifact correction using this synthetic ground-truth (SynGT). During testing, the output motion-corrected 2D image patches of the trained network are reinserted into the 3D CT volume with volumetric interpolation. The proposed method is evaluated using both phantom and clinical data. A phantom study demonstrates comparable results to other methods in quantitative performance and outperforms those methods in computation time. For clinical data, a quantitative analysis based on metric measurements is presented that confirms the correction of motion artifacts. Moreover, an observer study finds that by applying the proposed method, motion artifacts are markedly reduced, and boundaries of the coronary artery are much sharper, with a strong inter-observer agreement (κ=0.78). Finally, evaluations using commercial software on the original and resulting CT volumes of the proposed method reveal a considerable increase in tracked coronary artery length.

12 July 2025 in Journal of Echocardiography
Verified
Journal Article
Closed access
PDF file
JPJiesuck Park
Jiesuck Park
YYYeonyee E. Yoon
Yeonyee E. Yoon
YJYeonggul Jang
Yeonggul Jang
TJTaekgeun Jung
Taekgeun Jung
JJJaeik Jeon
Jaeik Jeon
HCHyuk-Jae Chang
Hyuk-Jae Chang

3 September 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
WXWu-Feng Xue
Wu-Feng Xue
JLJiahui Li
Jiahui Li
ZHZhiqiang Hu
Zhiqiang Hu
EKEric Kerfoot
Eric Kerfoot
JCJames Clough
James Clough
SLShuo Li
Shuo Li
Automatic quantification of the left ventricle (LV) from cardiac magnetic resonance (CMR) images plays an important role in making the diagnosis procedure efficient, reliable, and alleviating the laborious reading work for physicians. Considerable efforts have been devoted to LV quantification using different strategies that include segmentation-based (SG) methods and the recent direct regression (DR) methods. Although both SG and DR methods have obtained great success for the task, a systematic platform to benchmark them remains absent because of differences in label information during model learning. In this paper, we conducted an unbiased evaluation and comparison of cardiac LV quantification methods that were submitted to the Left Ventricle Quantification (LVQuan) challenge, which was held in conjunction with the Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop at the MICCAI 2018. The challenge was targeted at the quantification of 1) areas of LV cavity and myocardium, 2) dimensions of the LV cavity, 3) regional wall thicknesses (RWT), and 4) the cardiac phase, from mid-ventricle short-axis CMR images. First, we constructed a public quantification dataset Cardiac-DIG with ground truth labels for both the myocardium mask and these quantification targets across the entire cardiac cycle. Then, the key techniques employed by each submission were described. Next, quantitative validation of these submissions were conducted with the constructed dataset. The evaluation results revealed that both SG and DR methods can offer good LV quantification performance, even though DR methods do not require densely labeled masks for supervision. Among the 12 submissions, the DR method LDAMT offered the best performance, with a mean estimation error of 301 mm 2 for the two areas, 2.15 mm for the cavity dimensions, 2.03 mm for RWTs, and a 9.5% error rate for the cardiac phase classification. Three of the SG methods also delivered comparable performances. Finally, we discussed the advantages and disadvantages of SG and DR methods, as well as the unsolved problems in automatic cardiac quantification for clinical practice applications.