Luis Augusto Perles

Dr. Luis Augusto Perles

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
LWL L W Wang
L L W Wang
LPLuis Augusto Perles
Luis Augusto Perles
LAL Archambault
L Archambault
NSN Sahoo
N Sahoo
DMD Mirkovic
D Mirkovic
Sam BeddarSam Beddar
Sam Beddar
Plastic scintillation detectors (PSDs) have many advantages over other detectors in small field dosimetry due to their high spatial resolution, excellent water equivalence and instantaneous readout. However, in proton beams, the PSDs undergo a quenching effect which makes the signal level reduced significantly when the detector is close to the Bragg peak where the linear energy transfer (LET) for protons is very high. This study measures the quenching correction factor (QCF) for a PSD in clinical passive-scattering proton beams and investigates the feasibility of using PSDs in depth-dose measurements in proton beams. A polystyrene-based PSD (BCF-12, ϕ0.5 mm × 4 mm) was used to measure the depth-dose curves in a water phantom for monoenergetic unmodulated proton beams of nominal energies 100, 180 and 250 MeV. A Markus plane-parallel ion chamber was also used to get the dose distributions for the same proton beams. From these results, the QCF as a function of depth was derived for these proton beams. Next, the LET depth distributions for these proton beams were calculated by using the MCNPX Monte Carlo code, based on the experimentally validated nozzle models for these passive-scattering proton beams. Then the relationship between the QCF and the proton LET could be derived as an empirical formula. Finally, the obtained empirical formula was applied to the PSD measurements to get the corrected depth-dose curves and they were compared to the ion chamber measurements. A linear relationship between the QCF and LET, i.e. Birks' formula, was obtained for the proton beams studied. The result is in agreement with the literature. The PSD measurements after the quenching corrections agree with ion chamber measurements within 5%. PSDs are good dosimeters for proton beam measurement if the quenching effect is corrected appropriately.

10 November 2024 in Journal of Clinical Oncology
Verified
Journal Article
Closed access
ELEthan Ludmir
Ethan Ludmir
ASAlexander Sherry
Alexander Sherry
BFBryan M. Fellman
Bryan M. Fellman
SLSuyu Liu
Suyu Liu
TBTharakeswara Bathala
Tharakeswara Bathala
CTChad Tang
Chad Tang
PURPOSE: The EXTEND trial tested the hypothesis that adding comprehensive metastasis-directed therapy (MDT) to chemotherapy would improve progression-free survival (PFS) over chemotherapy alone among patients with oligometastatic pancreatic ductal adenocarcinoma (PDAC). METHODS: EXTEND (ClinicalTrials.gov identifier: NCT03599765 ) is a multicenter, phase II basket trial randomly assigning patients with ≤five metastases 1:1 to MDT plus systemic therapy versus systemic therapy. Disease progression was defined by radiologic criteria (RECIST v1.1), clinical progression, or death. The primary end point was PFS in the per-protocol population, evaluated after all patients achieved at least 6 months of follow-up. Exploratory end points included systemic immune response measures. RESULTS: Between March 19, 2019, and February 13, 2023, 41 patients were randomly assigned and 40 were eligible for the primary analysis of PFS (19 patients in the MDT arm; 21 patients in the control arm). At a median follow-up time of 17 months, the median PFS time was 10.3 months (95% CI, 4.6 to 14.0) in the MDT arm versus 2.5 months (95% CI, 1.7 to 5.1) in the control arm. PFS was significantly improved by the addition of MDT to systemic therapy ( P = .030 for stratified log-rank test) with a hazard ratio of 0.43 (95% CI, 0.20 to 0.94). No grade ≥3 or greater adverse events related to MDT were observed. Systemic immune activation events were associated with MDT and correlated with improved PFS. CONCLUSION: This study supports the addition of MDT to systemic therapy for patients with oligometastatic PDAC. Induction of systemic immunity is a possible mechanism of benefit. These results warrant confirmatory trials to refine treatment strategy and provide external validation.

1 March 1998 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
Igor PolikarpovIgor Polikarpov
Igor Polikarpov
LPLuis Augusto Perles
Luis Augusto Perles
ROR. T. de Oliveira
R. T. de Oliveira
GOG. Oliva
G. Oliva
ECE. E. Castellano
E. E. Castellano
ACA. Craievich
A. Craievich

26 August 2010 in Medical Physics
Verified
Journal Article
Closed access
GSGabriel O. Sawakuchi
Gabriel O. Sawakuchi
DMDragan Mirkovic
Dragan Mirkovic
LPLuis Augusto Perles
Luis Augusto Perles
NSNarayan Sahoo
Narayan Sahoo
XZX. Ron Zhu
X. Ron Zhu
UTUwe Titt
Uwe Titt

12 November 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
UTUwe Titt
Uwe Titt
DMDragan Mirkovic
Dragan Mirkovic
GSGabriel O Sawakuchi
Gabriel O Sawakuchi
LPLuis Augusto Perles
Luis Augusto Perles
WNWayne D Newhauser
Wayne D Newhauser
RMRadhe Mohan
Radhe Mohan
In scanned-beam proton therapy, the beam spot properties, such as the lateral and longitudinal size and the minimum achievable range, are influenced by beam optics, scattering media and drift spaces in the treatment unit. Currently available spot scanning systems offer few options for adjusting these properties. We investigated a method for adjusting the lateral and longitudinal spot size that utilizes downstream plastic pre-absorbers located near a water phantom. The spot size adjustment was characterized using Monte Carlo simulations of a modified commercial scanned-beam treatment head. Our results revealed that the pre-absorbers can be used to reduce the lateral full width at half maximum (FWHM) of dose spots in water by up to 14 mm, and to increase the longitudinal extent from about 1 mm to 5 mm at residual ranges of 4 cm and less. A large factor in manipulating the lateral spot sizes is the drift space between the pre-absorber and the water phantom. Increasing the drift space from 0 cm to 15 cm leads to an increase in the lateral FWHM from 2.15 cm to 2.87 cm, at a water-equivalent depth of 1 cm. These findings suggest that this spot adjustment method may improve the quality of spot-scanned proton treatments.

15 November 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
LPLuis Augusto Perles
Luis Augusto Perles
DMD Mirkovic
D Mirkovic
AAA Anand
A Anand
UTU Titt
U Titt
RMR Mohan
R Mohan
The dose response for films exposed to clinical x-ray beams is not linear and a calibration curve based on absorbed dose can be used to account for this effect. However for proton dosimetry the dose response of films exhibits an additional dependence because of the variation of the linear energy transfer (LET) as the protons penetrate matter. In the present study, we hypothesized that the dose response for EBT2 films can be mathematically described as a bimolecular chemical reaction. Furthermore, we have shown that the LET effect can be incorporated in the dose-response curve. A set of EBT2 films was exposed to pristine 161.6 MeV proton beams. The films were exposed to doses ranging from 0.93 to 14.82 Gy at a depth of 2 cm in water. The procedure was repeated with one film exposed to a lower energy beam (85.6 MeV). We also computed the LET and dose to water in the sensitive layer of the films with a validated Monte Carlo system, taking into account the film construction (polyester, adhesive and sensitive layers). The bimolecular model was able to accurately fit the experimental data with a correlation factor of 0.9998, and the LET correction factor was determined and incorporated into the dose-response function. We also concluded that the film orientation is important when determining the LET correction factor because of the asymmetric construction of the film.